We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime | 1/2 Circle Cylindrical Body Taper Point Needle HR 30 mm | USP 2/0 Gauge | Violet Thread 75 cm | Box of 12 units | Ref. P1L12HR3020

Original price was: 39,90 €.Current price is: 31,30 €.

Absorbable surgical multifilament suture of polyglactin 910 (PGLA) from the Premisut Prime range, with a 1/2 circle needle, cylindrical body and conical point (taperpoint) of 30 mm (HR30), USP 2/0 gauge and violet grooved braided thread of 75 cm. Predictable hydrolysis absorption between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide and single-use, it offers minimal tissue reaction, excellent handling and maximum knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Reference P1L12HR3020, supplied in a box of 12 units with B2B conditions for hospitals, clinics, distributors and purchasing centres.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L12HR3020

Description

1. Commercial Introduction

The absorbable multifilament suture of polyglactin 910 (PGLA) from the Premisut Prime range is the trusted choice for professionals seeking a synthetic resorbable thread with predictable behaviour, excellent handling and maximum knot security. Its 1/2 circle needle, cylindrical body and conical point (taperpoint) of 30 mm (HR30) ensures clean, atraumatic penetration, particularly suitable for tissue approximation, ligatures and ophthalmic surgery.

It is supplied in a box of 12 units, designed for B2B procurement by hospitals, clinics, distributors and purchasing centres for surgical material. Reference P1L12HR3020.

2. Technical Explanation

It is a braided (multifilament) synthetic absorbable suture made from polyglactin 910, a copolymer composed of 90% glycolide and 10% L-lactide. Its absorption mechanism is hydrolysis, a uniform and predictable process independent of tissue enzymes, with total mass loss between 56 and 72 days.

The thread, violet in colour with a grooved finish, offers excellent visibility on the surgical field, smooth passage through tissue and firm, secure knot anchorage. The cylindrical-body needle with a 1/2 circle curve and conical point of 30 mm separates the fibres without cutting them, minimising tissue trauma in delicate tissues such as those in ophthalmic surgery. The product is supplied sterile by ethylene oxide, is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Reference (SKU) P1L12HR3020
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided coated multifilament, fluted finish
Colour Violet (colourless available on request)
Gauge USP 2/0 (metric 3)
Thread length 75 cm
Needle shape 1/2 circle
Needle type Cylindrical body, conical tip (taperpoint)
Needle size HR 30 mm
Quality Prime (Premisut range)
Sterilisation Ethylene oxide, single-use
Presentation Box of 12 units

3.2. Absorption profile and tensile strength retention

Absorption type Hydrolysis
Absorption time 56 – 72 days
Tensile strength at 2 weeks 75 %
Tensile strength at 3 weeks 50 %
Tensile strength at 4 weeks 30 %
Tissue reaction Minimal
Knot tying Excellent safety

3.3. Size equivalence

USP size Metric size Approximate diameter
2/0 3 0.30 – 0.339 mm (indicative according to Pharmacopoeia)

Indications: tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units; consult B2B conditions for orders in multiples of boxes.

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used absorbable multifilament material in surgical practice and offers an absorption profile (56-72 days) and tensile strength retention equivalent to the braided lines of the leading international manufacturers:

Manufacturer Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided coated polyglactin 910, violet)
B. Braun Safil (braided polyglactin 910, violet)
Medtronic / Covidien Polysorb (absorbable braided PGLA range)
SMI Surgicryl (absorbable polyglactin 910)
Assut Sutures Range of polyglactin 910 with cylindrical 1/2 circle needles
Premisut range (Cahnos) Multifilament PGLA with 1/2 circle needle (HR series)

Within the Cahnos catalogue, the references closest to this configuration are:

Reference Description
P1L12HR3020.2 PGLA Prime, 1/2 circle taper point HR30, USP 2/0, violet, 2 x 75 cm (double presentation)
P1L12HRN3020 PGLA Prime, 1/2 circle blunt point HRN30, USP 2/0, violet, 75 cm (blunt point needle)
1L12HRN3020 PGLA, 1/2 circle blunt point HRN30, USP 2/0, violet, 75 cm (standard quality)
P1L12HR3030 PGLA Prime, 1/2 circle taper point HR30, USP 3/0, violet, 75 cm (smaller gauge)
P1L12HR2020 PGLA Prime, 1/2 circle taper point HR20, USP 2/0, violet, 75 cm (shorter needle)
P1L12HRN3030 PGLA Prime, 1/2 circle blunt point HRN30, USP 3/0, violet, 75 cm (blunt point, gauge 3/0)
AMP112HR3020 PGA Prime, 1/2 circle taper point HR30, USP 2/0, violet, 75 cm (polyglycolic acid alternative)

5. Selection tips and variants of interest

The USP 2/0 gauge (metric 3) offers an excellent balance between initial strength and handling for soft tissues, ligatures and microsurgery, being one of the most widely used gauges in ophthalmic surgery and in the approximation of delicate tissues. The 1/2 circle needle with cylindrical body and conical point (taperpoint) of 30 mm provides an atraumatic passage, without cutting effect, especially recommended when minimising tissue trauma is desired.

If the procedure requires longer strength retention (180-210 days), the polydioxanone (PDO) family is the recommended alternative. For other configurations of the same PGLA family in a box of 12 units, please refer to the variants already mentioned (20 mm, 36 mm needle, blunt point, 3/0 gauges or double thread presentation). Store the product in a cool, dry place, protected from sunlight and inside its sterile packaging until use, and contact our technical-commercial team for special B2B conditions and volume orders.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Braided coated multifilament, fluted finish

Gauge

USP 2/0 (metric 3)

Suture length

75 cm

Needle type

Cylindrical body, conical tip (taperpoint)

Sterilisation

Ethylene oxide, single-use

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Quality

Prime (Premisut range)

Medida de aguja

HR 30

Usp

2/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime | 1/2 Circle Cylindrical Body Taper Point Needle HR 30 mm | USP 2/0 Gauge | Violet Thread 75 cm | Box of 12 units | Ref. P1L12HR3020”

Your email address will not be published. Required fields are marked *