Description
1. Commercial Introduction
The absorbable multifilament suture of Polyglactin 910 (PGLA), reference 1L18HR4030 from the Premisut range, is the reference surgical closure solution for hospitals, ophthalmic clinics, private operating theatres and purchasing centres seeking a flexible, resistant synthetic thread with fully predictable absorption. Its ½ circle needle with cylindrical body and Taperpoint conical tip of 40 mm (HR 40) penetrates soft tissues separating the fibres without cutting them, which minimises trauma and makes it especially suitable for tissue approximation, ligatures and ophthalmic surgery.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for professional procurement. It is supplied in a box of 12 units with a minimum order of 30 boxes, ensuring continuous and traceable supply for your healthcare centre.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, low memory and firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes the suture ideal for tissues requiring wound support for 2 to 4 weeks of healing. The ½ circle needle with Taperpoint conical tip penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; the violet colour ensures optimal visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide (EO), single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference 1L18HR4030
| Characteristic | Specification |
| Reference (SKU) | 1L18HR4030 |
| Range / Quality | Premisut, Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Violet (colourless version available in the family) |
| Thread length | 70 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint conical |
| Needle size | 40 mm (HR 40) |
| Absorption mechanism | Hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.
3.3. Presentation and ordering conditions
| Value | Value |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
Polyglactin 910 is one of the most widely used synthetic absorbable materials in the European market. This reference is clinically comparable, in terms of composition, absorption profile and tension retention, to the braided multifilament sutures of the main manufacturers:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided coated Polyglactin 910, violet colour) |
| B. Braun | Safil (braided Polyglactin 910, violet colour) |
| Medtronic (Covidien) | Polysorb (braided absorbable Polyglactin 910 range) |
| SMI | Surgicryl (braided Polyglactin 910) |
| Assut | Assucryl 910 (Polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (TC / HR series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration of HR 40 mm needle, USP size 3/0 and 70 cm violet thread in superior quality is reference P1L18HR4030 (Prime range). As an alternative in polyglycolic acid (PGA) with the same needle geometry and absorption of 60 to 90 days, reference AM118HR4030 is available. The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the necessary size according to the anatomical area. USP size 3/0 (metric 2) is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general. The ½ circle needle with 40 mm conical tip (HR 40) is especially suitable for the approximation of soft and delicate tissues and for ophthalmic surgery, where atraumatic penetration is prioritised. For fibrous structures or the sclera, cutting or trocar points are recommended.
| Reference | Variant of interest |
| P1L18HR4030 | PGLA Prime quality, USP 3/0, HR 40 mm needle, violet, 70 cm (superior range) |
| 1L18HR4010 | PGLA USP 0, same HR 40 mm needle, violet, 70 cm (larger size) |
| 1L18HR4001 | PGLA USP 1, same HR 40 mm needle, violet, 70 cm (higher tension planes) |
| 1L18HR4002 | PGLA USP 2, same HR 40 mm needle, violet, 70 cm (maximum strength) |
| 1L18HR4830 | PGLA USP 3/0, HR 48 mm needle, violet, 70 cm (larger needle radius) |
| 1L12HR4020 | PGLA USP 2/0, HR 40 mm needle, violet, 75 cm (longer thread length) |
| AM118HR4030 | PGA USP 3/0, same HR 40 mm needle, violet, 70 cm (absorption 60-90 days) |
All references are supplied in a box of 12 units with a minimum order of 30 boxes. If you need a longer force retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.