We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 Premisut | Needle ½ Circle Cylindrical Conical Point Taperpoint HR 40 mm | USP Gauge 3/0 (Metric 2) | Violet Thread 70 cm | Ref. 1L18HR4030 – Box 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA), reference 1L18HR4030, mounted with a ½ circle needle with cylindrical body and Taperpoint conical tip of 40 mm (HR 40), USP size 3/0 (metric 2) and 70 cm braided violet thread. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation in a box of 12 units with a minimum order of 30 boxes, ideal for B2B procurement for hospitals, clinics and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L18HR4030

Description

1. Commercial Introduction

The absorbable multifilament suture of Polyglactin 910 (PGLA), reference 1L18HR4030 from the Premisut range, is the reference surgical closure solution for hospitals, ophthalmic clinics, private operating theatres and purchasing centres seeking a flexible, resistant synthetic thread with fully predictable absorption. Its ½ circle needle with cylindrical body and Taperpoint conical tip of 40 mm (HR 40) penetrates soft tissues separating the fibres without cutting them, which minimises trauma and makes it especially suitable for tissue approximation, ligatures and ophthalmic surgery.

It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for professional procurement. It is supplied in a box of 12 units with a minimum order of 30 boxes, ensuring continuous and traceable supply for your healthcare centre.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, low memory and firm, secure knot tying, with high initial tensile strength.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes the suture ideal for tissues requiring wound support for 2 to 4 weeks of healing. The ½ circle needle with Taperpoint conical tip penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; the violet colour ensures optimal visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide (EO), single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference 1L18HR4030

Characteristic Specification
Reference (SKU) 1L18HR4030
Range / Quality Premisut, Normal quality
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 3/0 (metric 2)
Thread colour Violet (colourless version available in the family)
Thread length 70 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Taperpoint conical
Needle size 40 mm (HR 40)
Absorption mechanism Hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal, with excellent tensile strength and knot security
Indications Tissue approximation, ligatures and ophthalmic surgery

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 30% of initial tensile strength
Total absorption 56-72 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.

3.3. Presentation and ordering conditions

Value Value
Presentation Box of 12 units
Minimum order 30 boxes
Format Sterile, single-use

4. Equivalences and Cross-References

Polyglactin 910 is one of the most widely used synthetic absorbable materials in the European market. This reference is clinically comparable, in terms of composition, absorption profile and tension retention, to the braided multifilament sutures of the main manufacturers:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided coated Polyglactin 910, violet colour)
B. Braun Safil (braided Polyglactin 910, violet colour)
Medtronic (Covidien) Polysorb (braided absorbable Polyglactin 910 range)
SMI Surgicryl (braided Polyglactin 910)
Assut Assucryl 910 (Polyglactin 910)
Laboratory Aragó Polyglactin 910 range with ½ circle needles (TC / HR series)

Within the Cahnos catalogue, its direct equivalent in the same configuration of HR 40 mm needle, USP size 3/0 and 70 cm violet thread in superior quality is reference P1L18HR4030 (Prime range). As an alternative in polyglycolic acid (PGA) with the same needle geometry and absorption of 60 to 90 days, reference AM118HR4030 is available. The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue and the necessary size according to the anatomical area. USP size 3/0 (metric 2) is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general. The ½ circle needle with 40 mm conical tip (HR 40) is especially suitable for the approximation of soft and delicate tissues and for ophthalmic surgery, where atraumatic penetration is prioritised. For fibrous structures or the sclera, cutting or trocar points are recommended.

Reference Variant of interest
P1L18HR4030 PGLA Prime quality, USP 3/0, HR 40 mm needle, violet, 70 cm (superior range)
1L18HR4010 PGLA USP 0, same HR 40 mm needle, violet, 70 cm (larger size)
1L18HR4001 PGLA USP 1, same HR 40 mm needle, violet, 70 cm (higher tension planes)
1L18HR4002 PGLA USP 2, same HR 40 mm needle, violet, 70 cm (maximum strength)
1L18HR4830 PGLA USP 3/0, HR 48 mm needle, violet, 70 cm (larger needle radius)
1L12HR4020 PGLA USP 2/0, HR 40 mm needle, violet, 75 cm (longer thread length)
AM118HR4030 PGA USP 3/0, same HR 40 mm needle, violet, 70 cm (absorption 60-90 days)

All references are supplied in a box of 12 units with a minimum order of 30 boxes. If you need a longer force retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.

Additional information

Reference

1L18HR4030

Product line

Premisut

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Metric gauge (EP)

2

Needle body

Cylindrical

Needle tip

Taperpoint conical

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HR 40

Usp

3/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable, Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 Premisut | Needle ½ Circle Cylindrical Conical Point Taperpoint HR 40 mm | USP Gauge 3/0 (Metric 2) | Violet Thread 70 cm | Ref. 1L18HR4030 – Box 12 units”

Your email address will not be published. Required fields are marked *