Description
1. Commercial Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture, reference 1L23HR4002 from the Premisut range, is the perfect surgical closure solution for the professional who demands a flexible, resistant thread with fully predictable absorption in the operating theatre. Its ½ circle needle with cylindrical body and conical point of 40 mm (HR 40) passes through soft tissues separating the fibres without tearing them, minimising trauma, which makes it especially suitable for tissue approximation, ligatures and ophthalmic surgery.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent value for money for B2B procurement for hospitals, ophthalmic clinics, private operating theatres and purchasing centres. It is presented in a box of 12 units with a minimum order of 30 boxes, which guarantees the continuous and traceable supply of your healthcare centre.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, very smooth handling and firm, secure knot tying, even in larger diameter gauges such as USP 2 (metric 5), ideal for tissues requiring high initial strength: deep planes, fascia, aponeurosis, high-tension closures and ligatures.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile makes the suture ideal for tissues requiring wound support for 2 to 4 weeks, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ½ circle needle with conical point penetrates by separating the fibres without cutting them, and the undyed colouration offers maximum aesthetic discretion on the surgical field. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference 1L23HR4002
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 1L23HR4002 |
| Brand / Range | Premisut – Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2 (metric 5) |
| Thread colour | Colourless |
| Thread length | 90 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taper point |
| Needle size | HR 40 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 56-72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Total absorption | 56-72 days (by hydrolysis) |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglactin 910 is one of the most widely used synthetic absorbable materials in the European market. This reference is clinically comparable, in terms of composition, absorption profile and tensile retention, to the braided multifilament sutures of the main manufacturers:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet and undyed) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (TC / HR series) |
Within the Cahnos catalogue, its twin in structure and geometry with the same HR 40 mm needle and USP 2 gauge is reference 1L13HR4002 (violet thread, 90 cm) and, in the same undyed colouration with a longer needle, 1L23HR4802 (HR 48 mm). As an alternative in polyglycolic acid (PGA) with the same needle geometry, reference AM123HR4002 is offered (absorption 60-90 days). The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 2 gauge (metric 5) is indicated for tissues requiring greater initial strength: deep planes, fascia, aponeurosis, high-tension closures and ligatures. The conical point is ideal for soft and friable tissues; for fibrous tissues or the sclera, reverse cutting or trocar points are recommended.
| Reference | Variant |
|---|---|
| 1L23HR4002 | PGLA USP 2, HR 40 mm needle, undyed thread, 90 cm (current product) |
| 1L13HR4002 | PGLA USP 2, HR 40 mm needle, violet thread, 90 cm (same geometry, maximum visibility in the field) |
| 1L13HR4502 | PGLA USP 2, HR 45 mm needle, violet thread, 90 cm (intermediate needle) |
| 1L23HR4802 | PGLA USP 2, HR 48 mm needle, undyed thread, 90 cm (longer needle, same colouration) |
| 1L18HR4002 | PGLA USP 2, HR 40 mm needle, violet thread, 70 cm (shorter thread length) |
| 1L13HS4002 | PGLA USP 2, triangular reverse cutting needle HS 40 mm, violet thread, 90 cm (firm tissues) |
| AM123HR4002 | PGA USP 2, HR 40 mm needle, undyed thread, 90 cm (alternative in polyglycolic acid, absorption 60-90 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee the continuous supply of your healthcare centre. For longer force retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.





Reviews