Description
1. Introduction
The absorbable multifilament PGLA (Polyglactin 910) suture from the Prime range, reference P1L12HR2601, is the professional reference solution for B2B supply to operating theatres, ophthalmology clinics and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional thread handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.
Its ½ circle needle with cylindrical body and 26 mm conical point (HR 26) ensures an atraumatic passage through tissue, while the 75 cm violet thread in USP 1 gauge offers optimal visibility on the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio for continuous use.
2. Technical Explanation
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, excellent flexibility, firm and secure knot tying and smooth traction, essential qualities in soft and friable tissues.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circular needle with cylindrical body and conical point (taperpoint) HR 26 mm allows controlled and atraumatic penetration, with minimal damage to the tissue bed, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L12HR2601
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (Premisut range) |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet (also available undyed) |
| Needle shape | ½ circle |
| Tip type | Conical point (taperpoint), cylindrical body |
| Needle size | HR 26 mm |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L12HR2601 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. USP 1 gauge (metric 4) provides high tensile support for tissues subjected to moderate-high traction.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:
| Manufacturer | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Polysorb (absorbable braided range of polyglactin 910) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglycolic acid (PGA) family is reference AMP112HR2601 (cylindrical HR 26 mm needle, USP 1, violet, 75 cm, absorption 60-90 days). In the same PGLA Prime range, the variant with reverse cutting triangular point corresponds to reference P1L18HS2610 (HS 26 mm, USP 0, violet, 70 cm). *The brands cited belong to their respective manufacturers and are mentioned only as a reference for equivalence.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue and the necessary gauge according to the anatomical area. USP 1 gauge is indicated for tissues with moderate-high tension: fascia, aponeurosis, deep subcutaneous tissue and medium-calibre vascular ligatures. The 26 mm HR conical point needle is the recommended atraumatic option for soft and friable tissues, as well as for ophthalmic surgery.
| Reference | Variant |
|---|---|
| P1L12HR2601 | PGLA Prime USP 1, cylindrical HR 26 mm needle, violet, 75 cm (current product) |
| P1L12HR2610 | PGLA Prime USP 0, cylindrical HR 26 mm needle, violet, 75 cm (smaller gauge) |
| P1L12HR2602 | PGLA Prime USP 2, cylindrical HR 26 mm needle, violet, 75 cm (higher strength) |
| P1L12HR2620.2 | PGLA Prime USP 2/0, HR 26 mm needle, violet, 2×75 cm (double version) |
| AMP112HR2601 | PGA Prime USP 1, HR 26 mm needle, violet, 75 cm (absorption 60-90 days) |
| P1L18HS2610 | PGLA Prime USP 0, triangular HS 26 mm needle, violet, 70 cm (reverse cutting) |
If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team.