Description
1. Introduction
The absorbable multifilament suture of polyglactin 910 (PGLA) in Prime quality from the Premisut range is the reference choice for hospitals, private clinics, ophthalmologists and purchasing groups seeking a high-performance synthetic thread with a very competitive price-quality ratio. This presentation combines a ½ circle needle, cylindrical body and conical point (Taperpoint) of 45 mm (HR 45), USP gauge 0 and violet thread of 75 cm.
Each unit is supplied sterile and ready to use, with the professional distribution warranty of Cahnos. It is especially indicated for the approximation of soft tissues, ligatures and ophthalmic surgery, where precision, manageability and fully predictable absorption are required during the first weeks of healing.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure with a grooved finish gives it great flexibility, low memory and a contained friction coefficient, which favours the sliding of the thread through tissue and firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, maintaining wound support during the critical 2 to 4 weeks of healing and with minimal tissue reaction. The ½ circle needle with cylindrical body and conical point passes through tissues separating the fibres without cutting them, which minimises trauma to delicate structures; it is especially recommended in ophthalmic surgery and in the approximation of friable tissues. The violet colour of the thread guarantees optimal visibility in the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet
| Characteristic | Specification |
|---|---|
| Reference (SKU) | P1L12HR4510 |
| Range / Quality | Premisut, Prime quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Colour | Violet |
| Gauge | USP 0 (metric 3.5) |
| Thread length | 75 cm |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 45 mm (HR 45 Prime) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 56-72 days |
| Sterilisation | Ethylene oxide (EO), single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.
3.3. Presentation and ordering conditions
| Value | Value |
|---|---|
| Reference (SKU) | P1L12HR4510 |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture belongs to the family of braided synthetic absorbable sutures of medium absorption, clinically equivalent in composition, absorption profile and mechanical behaviour to the reference lines of the international market:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910, violet) |
| Laboratory Aragó | Polyglactin 910 range with 1/2 circle needles (HR series) |
The ½ circle format with cylindrical body and conical point of 45 mm corresponds to the classic pattern of medium-gauge taper needles used in general surgery, gynaecology, abdominal wall and ophthalmology. Within the Cahnos catalogue, this reference is directly related to: 1L12HR4810 (Normal quality, HR 48 mm needle), P1L12HR4810 (same quality and gauge with HR 48 mm needle), AMP112HR4510 (alternative in PGA family with the same HR 45 mm needle, USP 0 and 75 cm), P1L12HR4520 (same configuration in USP gauge 2/0), P1L13HR4810 (gauge 0 with 90 cm thread) and P1L15HR48L10 (loop format of 150 cm). The indicated equivalences are for guidance; for a formal substitution, consult our technical-commercial department.
5. Selection tips and variants of interest
USP gauge 0 (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and ophthalmic surgery procedures, with an excellent balance between initial strength and predictable absorption during a healing period of 2 to 4 weeks. For finer tissues, gauges 2/0 or smaller are recommended, while gauge 1 is reserved for areas subject to greater traction.
In ophthalmic surgery, prioritise ½ circle needles: the conical point (Taperpoint) separates the fibres without cutting them, ideal for soft and delicate tissues; the blunt point offers maximum atraumaticity and the trocar point is reserved for fibrous and dense structures such as the sclera. Check the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area to be treated.
- For longer strength retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative.
- If you require a longer thread length, consult the 90 cm version (P1L13HR4810) or the 150 cm loop format (P1L15HR48L10).
- As it is a sterile single-use product, always check the integrity of the packaging before each procedure and respect the traceability required by the centre.
Consult our technical-commercial team for special volume conditions: the minimum order is 30 boxes, with scheduled deliveries for hospitals, clinics and purchasing groups.





Reviews
There are no reviews yet.