Description
1. Commercial presentation
The Absorbable Multifilament Polyglactin 910 (PGLA) Suture in Prime quality (range PREMISUT), reference P1L12HR3620, is the trusted choice for the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security. Its ½ circle needle with cylindrical body and conical Taperpoint point, 36 mm (HR 36), allows clean and atraumatic penetration, particularly suitable for ophthalmic surgery, ligatures and approximation of soft tissues. It is supplied in a box of 12 units, optimising the logistics of operating theatres, clinics, hospitals and surgical material purchasing centres, with B2B conditions adapted to orders in multiples of boxes.
2. Technical explanation
Polyglactin 910 (PGLA) is a biocompatible synthetic copolymer composed of 90% glycolide and 10% L-lactide, structured as a coated braided multifilament that provides great flexibility, low memory and smooth passage through tissue, with firm and secure knot tying. Its absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity, maintaining wound edge apposition during the critical healing phase (2 to 4 weeks). The HR 36 mm needle, with cylindrical body and conical Taperpoint point, separates fibres without cutting effect, minimising trauma to delicate structures. The violet colour ensures optimal visibility on the surgical field. The product is supplied sterile by ethylene oxide (EtO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Reference (SKU) | P1L12HR3620 |
| Brand / Quality | Premisut – Prime |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided coated multifilament, fluted finish |
| Thread colour | Violet |
| Gauge | USP 2/0 (metric 3) |
| Thread length | 75 cm |
| Needle shape | ½ circle |
| Needle type | Cylindrical body, conical Taperpoint tip |
| Needle size | HR 36 mm (Prime) |
| Sterilisation | Ethylene oxide (EtO) |
| Tissue reaction | Minimal |
| Presentation | Box of 12 units |
3.2. Absorption profile and tensile strength retention
| Parameter | Value |
|---|---|
| Absorption type | Hydrolysis |
| Absorption time | 56 – 72 days |
| Tensile strength at 2 weeks | 75 % |
| Tensile strength at 3 weeks | 50 % |
| Tensile strength at 4 weeks | 30 % |
| Tissue reaction | Minimal |
| Knot tying | Excellent safety |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
Indications: tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units; consult B2B conditions for orders in multiples of boxes.
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used absorbable multifilament material in surgical practice. This Prime reference behaves as a functional equivalent of the braided polyglactin 910 sutures from the main international manufacturers, with equivalent absorption profiles (56 – 72 days) and tensile strength retention:
| Manufacturer | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus |
| B. Braun | Safil / Surgicryl |
| Medtronic | Polysorb |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 |
| Laboratory Aragó | Polyglactin 910 range with ½ circle cylindrical needles (TC / HR series) |
Within the Cahnos catalogue, this configuration (HR 36 mm needle, USP 2/0 gauge, 75 cm violet thread) corresponds to Prime quality; the standard version of the same configuration is reference 1L12HR3620 and the warehouse version AM1L12HR3620. In 90 cm length, the equivalent variant is P1L13HR3620, with its colourless version P1L23HR3620. The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
USP 2/0 gauge (metric 3) offers an excellent balance between initial strength and manageability for soft tissues under moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in ophthalmic surgery. The ½ circle needle with conical Taperpoint point is the most atraumatic option for delicate tissues; if greater penetration in firm tissues is required, consider trocar or reverse cutting points.
| Reference | Variant |
|---|---|
| P1L12HR3620 | PGLA Prime, HR 36 mm needle, USP 2/0, violet, 75 cm (current product) |
| P1L12HR3630 | PGLA Prime, HR 36 mm needle, USP 3/0, violet, 75 cm |
| P1L12HR2620 | PGLA Prime, HR 26 mm needle, USP 2/0, violet, 75 cm |
| P1L12HR3020 | PGLA Prime, HR 30 mm needle, USP 2/0, violet, 75 cm |
| P1L12JR3620 | PGLA Prime, hook needle (J-Hook) JR 36 mm, USP 2/0, violet, 75 cm |
| P1L12HRN3620H | PGLA Prime Heavy, blunt point needle HRN 36 mm, USP 2/0, violet, 75 cm |
| P1L13HR3620 | PGLA Prime, HR 36 mm needle, USP 2/0, violet, 90 cm |
| P112HR3620 / AMP112HR3620 | PGA Prime, HR 36 mm needle, USP 2/0, violet, 75 cm (absorption 60 – 90 days) |
If you need a longer strength retention (180 – 210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.





Reviews