Description
The Absorbable Multifilament PGLA Suture (Polyglactin 910) from the Prime range by Premisut, reference P1L18HR3601, is the reference solution in the operating theatre for hospitals, private clinics, ophthalmologists and purchasing centres looking for a high-performance absorbable synthetic thread with a very competitive price-quality ratio.
This 70 cm presentation in violet combines a USP 1 gauge of high initial strength with a ½ circle cylindrical needle with a conical point of 36 mm, ideal for precision procedures. Each unit is supplied sterile, ready to use and single-use, with the professional distribution warranty of Cahnos. It is supplied in a box of 12 units with a minimum order of 30 boxes, ensuring continuity of supply for your healthcare centre.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration favours the sliding of the thread through the tissue, offering smooth handling, low memory and firm, secure knot tying in medium gauges such as USP 1.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and conical point of 36 mm penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery, approximation of soft tissues and ligatures. The violet colour ensures optimal visibility in the surgical field. Product sterile by ethylene oxide, single-use and not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P1L18HR3601
| Characteristic | Specification |
| Reference (SKU) | P1L18HR3601 |
| Brand / Quality | Premisut – Prime |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet; colourless version available in the family |
| Thread length | 70 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | 36 mm (HR 36 Prime) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglactin 910 is one of the most well-established synthetic absorbable suture raw materials on the market. This braided multifilament suture with medium absorption is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines on the international market:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle cylindrical needles (TC/HR series) |
Within the Cahnos catalogue, its direct equivalent in single-thread format of 90 cm is reference P1L13HR3601, and the colourless 70 cm version corresponds to reference P1L28HR3601. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues requiring high initial strength: aponeurosis, fascia, muscle planes, abdominal wall and high-tension closures. The ½ circle needle with conical point of 36 mm is ideal for soft and delicate tissues, with special application in ophthalmic surgery; for firmer and denser structures (e.g. sclera), reverse cutting or trocar points are recommended.
| Reference | Variant |
| P1L18HR3601 | PGLA Prime USP 1, HR 36 mm needle, violet, 70 cm (current product) |
| P1L18HR3610 | PGLA Prime USP 0, HR 36 mm needle, violet, 70 cm (fine gauge) |
| P1L13HR3601 | PGLA Prime USP 1, HR 36 mm needle, violet, 90 cm (longer thread) |
| P1L13HR3601.2 | PGLA Prime USP 1, HR 36 mm needle, violet, 2 x 90 cm (double format) |
| P1L28HR3601 | PGLA Prime USP 1, HR 36 mm needle, colourless, 70 cm (colourless version) |
| P1L18HS3601 | PGLA Prime USP 1, triangular HS 36 mm needle, violet, 70 cm (firm tissues) |
| AMP118HR3601 | PGA Prime USP 1, HR 36 mm needle, violet, 70 cm (absorption 60-90 days) |
All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to ensure continuous supply to your healthcare centre. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.





Reviews
There are no reviews yet.