Description
1. Commercial Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture in Prime Heavy quality from the Premisut range is the reference choice in the operating theatre for hospitals, private clinics, ophthalmology teams and purchasing centres seeking a high-performance synthetic thread with an excellent quality-price ratio. This reference mounts a ½ circle needle with cylindrical body and taper point of 30 mm (HR 30 Prime), USP 1 gauge and violet braided thread of 75 cm, under code P1L12HR3001H. Each unit is supplied sterile and ready to use, ideal for tissue approximation, ligatures and ophthalmic surgery, where precision, handling and fully predictable absorption during the first weeks of healing are required.
2. Technical explanation of the material and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented as a braided multifilament with coating. This structure confers great flexibility, low memory, smooth sliding and a contained friction coefficient that favours firm and secure knot tying. Absorption occurs by hydrolysis, independent of the patient’s enzymatic activity, over a predictable period of 56 to 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. The ½ circle needle with cylindrical body and taper point passes through tissue by separating fibres without cutting them, minimising trauma to delicate structures, and is especially recommended in ophthalmic surgery and soft tissues. The violet colour ensures optimal visibility of the thread in the surgical field. Sterile single-use product, not for re-sterilisation.
3. Technical Specifications
| Reference (SKU) | P1L12HR3001H |
| Brand / Quality | Premisut – Prime Heavy |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided and coated multifilament |
| Gauge | USP 1 (metric 4) |
| Thread length | 75 cm |
| Thread colour | Violet (also available colourless) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | 30 mm (HR 30 Prime Heavy) |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use |
| Presentation | Box of 12 units · Minimum order 30 boxes |
Tensile strength retention and absorption profile:
| Period | Retention of initial tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Total absorption | 56–72 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and knot security, with predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture belongs to the family of synthetic absorbable braided sutures of medium absorption, clinically equivalent in composition, absorption profile and mechanical behaviour to the reference lines on the international market:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
Within the Cahnos catalogue, this reference shares a family with the PGLA line of ½ circle cylindrical needle: its direct equivalent in the same HR 30 mm USP 1 configuration corresponds to the Heavy version without Prime (1L12HR3001H) and the Prime version without Heavy reinforcement (P1L12HR3001). The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the gauge according to the anatomical area. USP 1 gauge provides high initial strength and is suitable for tissues under tension, aponeuroses and tension closures; gauges 0 and 2/0 are intended for more delicate planes. The taper point is ideal for soft tissues and delicate structures such as ocular ones; for fibrous tissues or the sclera, trocar-type penetration points are recommended. Variants of interest in the same PGLA Prime Heavy family: P1L12HR3010H (Prime Heavy USP 0, smaller gauge), P1L12HR4001H (Prime Heavy USP 1, HR 40 mm needle with larger radius), P1L18JR3001 (JR 30 mm hook needle) and P1L12RHRP3001 (Ultra Plus trocar point for fibrous tissues). All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to ensure continuous supply to your centre. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team at Cahnos.