Description
1. Commercial Introduction
At Cahnos we provide you with the absorbable multifilament polyglactin 910 (PGLA) suture of Prime quality, reference P1L28HR2220, the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, ambulatory surgery units and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.
Its ½ circle needle with cylindrical body and conical point (taperpoint) of 22 mm guarantees atraumatic penetration, while the colourless fluted thread of 70 cm offers maximum discretion on the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that favours the passage of the thread through tissue, smooth handling, low memory and firm, secure knot tying even in fine calibres such as USP 2/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and conical point (taperpoint) passes through tissues separating the fibres without cutting effect, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery and in the approximation of soft tissues. The product is sterilised by ethylene oxide, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference P1L28HR2220
| Characteristic | Specification |
|---|---|
| Reference (SKU) | P1L28HR2220 |
| Brand / Quality | Premisut – Prime |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| USP / metric gauge | 2/0 (metric 3) |
| Thread colour | Colourless (also available in violet) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | 22 mm (HR 22 Prime) |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units; minimum order of 30 boxes.
3.3. Needle configuration
| Configuration | Value |
|---|---|
| Needle shape | ½ circle |
| Body | Cylindrical |
| Tip | Taperpoint (taperpoint, atraumatic) |
| Needle size | 22 mm (HR 22) |
| Needle type | HR 22 Prime |
4. Equivalences and Cross-References
Polyglactin 910 is one of the most well-established synthetic absorbable multifilament suture raw materials on the market. This Prime reference is clinically equivalent, in chemical composition, absorption profile (56-72 days) and tensile strength retention, to the main international lines:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| DemeTECH | Vitacryl (coated braided polyglactin 910) |
| Laboratory Aragó | Premisut range of polyglactin 910 with ½ circle needles |
Within the Cahnos catalogue, its closest references by HR 22 mm needle configuration and calibre 2/0 are the violet version P1L18HR2220 and the version with high-visibility VisiBlack needle P1L18HR2220VB. The equivalences indicated are indicative; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, take into account the wound support time required by the tissue to be sutured and the necessary calibre according to the anatomical area. USP 2/0 (metric 3) calibre is indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, being widely used in ophthalmic surgery. The ½ circle needle with conical point of 22 mm is the most atraumatic option for delicate tissues; if you need greater penetration in firm tissues, consider trocar or reverse cutting points.
| Reference | Variant |
|---|---|
| P1L28HR2230 | PGLA Prime USP 3/0, HR 22 mm needle, colourless, 70 cm (finer gauge) |
| P1L28HR2240 | PGLA Prime USP 4/0, HR 22 mm needle, colourless, 70 cm (finest) |
| P1L18HR2220 | PGLA Prime USP 2/0, HR 22 mm needle, violet, 70 cm (greater thread visibility) |
| P1L12HR2220 | PGLA Prime USP 2/0, HR 22 mm needle, violet, 75 cm (longer thread) |
| P1L28HR2620 | PGLA Prime USP 2/0, HR 26 mm needle, colourless, 70 cm (larger needle radius) |
| P1L28RHRP2220 | PGLA Prime USP 2/0, HRP 22 mm needle with Ultra Plus trocar point, colourless, 70 cm (greater penetration) |
| AMP128HR2220 | Alternative in polyglycolic acid (PGA), same HR 22 mm needle, USP 2/0, colourless, 70 cm (absorption 60-90 days) |
If you need a longer retention profile (180-210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to your healthcare centre. As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.