Description
1. Commercial Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture from the Premisut Prime range, reference P1L12HRN3610, is the trusted solution for the professional seeking a synthetic resorbable thread with predictable behaviour, excellent handling and maximum knot security. Its ½ circle needle with cylindrical body and blunt point of 36 mm (HRN 36) ensures clean and atraumatic penetration, particularly suitable for tissue approximation, ligatures and ophthalmic surgery.
It is presented in B2B format in a box of 12 units with a minimum order of 30 boxes, designed for the supply of operating theatres, ophthalmic clinics, distributors and purchasing centres for surgical material, ensuring the continuous supply of your healthcare facility with an excellent value for money.
2. Technical Explanation
It is a braided (multifilament) absorbable synthetic suture made from polyglactin 910, a copolymer composed of 90 % glycolide and 10 % L-lactide. Its absorption mechanism is hydrolysis, a uniform and predictable process, independent of tissue enzymes, with total mass loss between 56 and 72 days.
The thread, violet in colour with a grooved finish, offers excellent visibility on the surgical field, smooth passage through tissue and firm, secure knot anchorage. The needle with cylindrical body in a ½ circle curve with a blunt point of 36 mm separates the fibres without cutting them, minimising tissue trauma in delicate tissues such as those of ophthalmic surgery and in patients with friable tissues. The product is supplied sterile by ethylene oxide, is single-use and does not allow re-sterilisation. The integrity of the packaging must always be checked before each procedure and the traceability required by the facility must be respected.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided coated multifilament, fluted finish |
| Quality | Prime (Premisut range) |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Violet (colourless available on request) |
| Needle shape | ½ circle, cylindrical body |
| Tip type | Blunt tip |
| Needle size | HRN 36 mm |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EtO), single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L12HRN3610 |
3.2. Absorption profile and tensile strength retention
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used absorbable multifilament material in surgical practice. This reference behaves as a functional equivalent of the braided polyglactin 910 sutures from the main international manufacturers, all of them with equivalent absorption profiles (56-72 days) and tensile strength retention:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided coated polyglactin 910, violet) |
| B. Braun | Safil / Surgicryl (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (absorbable polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (470xx series and HRN/HR series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (HRN 36 mm needle, USP 0 gauge, violet, 75 cm) in normal quality is reference 1L12HRN3610; the alternative with similar performance in polyglycolic acid (PGA) with the same needle is reference AMP112HRN3610.
5. Selection tips and variants of interest
The USP 0 gauge (metric 3.5) offers an excellent balance between initial strength and handling, very suitable for approximation of soft tissues, fascia, aponeurosis, abdominal wall, ligation of medium-calibre vessels and ophthalmic surgery procedures. The ½ circle needle with blunt point HRN 36 mm is especially recommended in friable or delicate tissues, where the needle passage must be clean and atraumatic; if a point that penetrates firmer tissues is preferred, there are versions with conical point HR of 36 mm or trocar point HRT of 36 mm in the same range.
| Reference | Description |
|---|---|
| P1L12HRN3610 | PGLA Prime, ½ circle blunt point HRN 36 mm, USP 0, violet, 75 cm (current reference) |
| 1L12HRN3610 | PGLA, ½ circle blunt point HRN 36 mm, USP 0, violet, 75 cm (normal quality) |
| P1L12HRN3620 | PGLA Prime, ½ circle blunt point HRN 36 mm, USP 2/0, violet, 75 cm (finer gauge) |
| P1L12HRN3620H | PGLA Prime Heavy, ½ circle blunt point HRN 36 mm, USP 2/0, violet, 75 cm (reinforced version) |
| P1L13HRN3610H | PGLA Prime Heavy, ½ circle blunt point HRN 36 mm, USP 0, violet, 90 cm (longer thread length) |
| P1L13HRT3610 | PGLA Prime, ½ circle trocar point HRT 36 mm, USP 0, violet, 90 cm (for fibrous tissues) |
| P1L13HR3610 | PGLA Prime, ½ circle conical point HR 36 mm, USP 0, violet, 90 cm (atraumatic point) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare facility. For longer strength retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. For special B2B conditions and volume orders, contact our technical-commercial team at Cahnos.





Reviews