Description
1. Introduction
The absorbable Prime Poliglactina 910 (PGLA) suture we present is the reliable choice for surgical teams seeking a high-performance synthetic multifilament thread at a very competitive price. Mounted with a ½ circle needle, cylindrical body and Trocar Ultra Plus (HRP) point of 48 mm, it is indicated for tissue approximation, ligatures and, notably, ophthalmic surgery, where precision, manageability and predictable absorption are required.
Each unit arrives sterile and ready to use, with the maximum quality of the Prime range and the warranty of professional distribution by Cahnos for hospitals, private clinics and wholesalers in the sector. Presentation in a box of 12 units, reference P1L18RHRP4820.
2. Technical explanation
Poliglactina 910 is a copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure gives it great flexibility and excellent handling, with low memory and a contained coefficient of friction that favours sliding and knot tying with maximum safety.
The thread is absorbed by hydrolysis, which provides a predictable and constant loss of resistance over time, with total absorption between 56 and 72 days. The ½ circle needle with cylindrical body and Trocar Ultra Plus point combines a rounded body that passes through tissue with minimal injury and an optimised penetration point for more fibrous tissues, with smooth and less traumatic passage. The violet colouration guarantees optimal visibility throughout the procedure.
3. Technical Specifications
General characteristics
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Structure | Braided multifilament |
| Thread colour | Violet |
| Gauge | USP 2/0 |
| Thread length | 70 cm |
| Sterilisation | Ethylene oxide (EO), single-use / sterile |
| Needle: shape | ½ circle |
| Needle: body | Cylindrical |
| Needle: point | Trocar Ultra Plus (Taperpoint) |
| Needle: radius / code | HRP 48 mm, Prime quality |
| Quality | Prime |
| Reference | P1L18RHRP4820 |
| Presentation | Box of 12 units |
Absorption profile and tensile strength
| Time | Remaining tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 30 % of initial tensile strength |
| Total absorption | 56 – 72 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and knot tying, with a predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This Poliglactina 910 suture belongs to the family of synthetic absorbable braided sutures of medium absorption, clinically equivalent to the reference poliglactina 910 sutures on the market (such as Vicryl and Vicryl Plus from Ethicon, Surgicryl or Safil from B. Braun, among others).
Within the Cahnos catalogue, it is related to the following references:
- P1L18RHRP4810 – same HRP 48 mm needle Trocar Ultra Plus point, gauge 0, violet thread 70 cm.
- P1L18RHRP4830 – same HRP 48 mm needle Trocar Ultra Plus point, gauge 3/0, violet thread 70 cm.
- P1L18RHRP4801 – same HRP 48 mm needle Trocar Ultra Plus point, gauge 1, violet thread 70 cm.
- P1L13RHRP4820 – same configuration (HRP 48 mm needle, gauge 2/0) in violet and 90 cm thread.
- P1L18RHRP4020 – HRP 40 mm needle Trocar Ultra Plus point, gauge 2/0, violet thread 70 cm.
5. Selection tips and variants of interest
In ophthalmic surgery, prioritise ½ circle needles: the Trocar Ultra Plus point is ideal for sclera and fibrous tissues, while the classic conical point is reserved for soft tissues. The USP 2/0 gauge offers an optimal balance between strength and delicacy, suitable for fine tissue planes and approximation techniques; 3/0 gauges are intended for more delicate tissues and gauge 0 or 1 for tissues subjected to greater traction. Verify the needle radius (HRP 22, 26, 30, 40 or 48 mm) according to the depth and surgical area.
As it is a sterile single-use product, check the integrity of the packaging before each procedure and respect the traceability required by the centre. Consult our commercial team for special volume conditions for hospitals and purchasing centres.