Description
1. Commercial presentation
At Cahnos we offer the absorbable multifilament polyglactin 910 (PGLA) suture of Prime quality, reference P1L18RHRP2640, designed for the professional who demands reliable, manageable and predictable performance in the operating theatre. This presentation combines a 1/2 circle cylindrical-body HRP 26 mm needle with an Ultra Plus trocar point, USP gauge 4/0 and a 70 cm violet suture with high visibility against the tissue. It is an excellent option for approximation of soft tissues, ligatures and ophthalmic surgery, with predictable absorption that avoids the need for removal. It is supplied in a box of 12 units, sterile by ethylene oxide and ready for immediate use in the operating theatre.
2. Technical explanation
Polyglactin 910 is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, structured as a coated (grooved) braided multifilament that ensures smooth passage through tissue, excellent knot tying and high initial tensile strength. Its absorption occurs by hydrolysis over an interval of 56 to 72 days, with progressive and predictable loss of strength and minimal tissue reaction, making it especially safe in delicate tissues.
The 1/2 circle cylindrical-body needle with Ultra Plus trocar point (designation HRP26) penetrates tissue with lower penetration resistance and without cutting effect on adjacent tissue, minimising trauma and improving control in precision areas such as the ocular surface and lax tissues. The product is supplied sterile by ethylene oxide (EO) and is single-use.
3. Technical Specifications
Main features of reference P1L18RHRP2640:
| Characteristic | Detail |
|---|---|
| Reference | P1L18RHRP2640 |
| Material | Polyglactin 910 (PGLA): 90% glycolide / 10% L-lactide |
| Thread structure | Multifilament braided coated (fluted) |
| USP / metric gauge | 4/0 (metric 1.5) |
| Thread length | 70 cm |
| Colour | Violet |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle size | 26 mm (HRP 26 Prime) |
| Needle tip | Trocar Ultra Plus (taperpoint conical tip) |
| Absorption | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (EO), single-use |
| Quality | Prime (Premisut) |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
Tensile strength retention and absorption profile:
| Period | Tensile strength retention |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56 – 72 days by hydrolysis |
4. Equivalences and Cross-References
Polyglactin 910 is one of the classic compositions in synthetic absorbable multifilament sutures on the market. This Prime reference from Cahnos is clinically equivalent, both in chemical composition and in absorption profile (56-72 days) and tensile strength retention, to the Vicryl lines from Ethicon (Johnson & Johnson), to the Safil range from B. Braun, to Polysorb from Medtronic/Covidien and to the polyglactin 910 ranges from SMI (Surgicryl). The HRP needle with Ultra Plus trocar point is functionally equivalent to the reinforced conical needles with penetration point (taperpoint type) used by the main manufacturers for 26 mm cylindrical-body needles. Within the Cahnos catalogue, this reference is part of the PGLA Prime line with HRP needle and Ultra Plus trocar point, available in different gauges and suture lengths.
5. Selection tips and variants of interest
USP gauge 4/0 with a 26 mm HRP needle and Ultra Plus trocar point is a high-precision choice for very delicate tissues, ophthalmic surgery, approximation of fine tissues and ligatures in areas with limited access. If you require the same needle profile in other gauges, the HRP26 family is available: P1L18RHRP2630 (USP 3/0), P1L18RHRP2620 (USP 2/0), P1L18RHRP2610 (USP 0), P1L18RHRP2601 (USP 1) and P1L18RHRP2602 (USP 2), all in 70 cm violet suture. For 90 cm suture, please see references P1L13RHRP2630 (USP 3/0) and P1L13RHRP2620 (USP 2/0); if you prefer the undyed version, P1L28RHRP2630 and P1L28RHRP2620 are available. As this is sterile single-use material, it must be discarded after the procedure and stored in a cool, dry place, protected from sunlight and inside its sterile packaging until use. Contact our technical-commercial team for special volume conditions and hospital supply contracts.