We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 Premisut Prime – Double Needle 1/2 Circle Cylindrical Body Conical Point Ultra Plus 17 mm (HRP17), USP 3/0, Violet, 2×70 cm – Box of 12 units | Ref. P1L18HRP1730-2

Original price was: 84,90 €.Current price is: 68,90 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA) in Premisut Prime quality, presented with double atraumatic 1/2 circle needle with cylindrical body and Ultra Plus conical point of 17 mm (HRP17). Gauge USP 3/0, violet non-channeled thread of 2×70 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tension retention of 75 % at 2 weeks and excellent knot security. Sterile by ethylene oxide and minimal tissue reaction; indicated for approximation of soft tissues, ligatures and ophthalmic surgery. Reference P1L18HRP1730-2, in box of 12 units and minimum order of 10 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18HRP1730-2

Description

1. Product Presentation

The Absorbable Multifilament Suture of Polyglactin 910 (PGLA) from the Premisut Prime range is the synthetic absorbable solution designed for the professional who demands predictable performance, excellent tensile strength and great knot security. This reference incorporates a double 1/2 circle needle with a cylindrical body and Ultra Plus conical point of 17 mm (HRP17), which makes it especially useful in ophthalmic surgery and precision techniques where two mounted threads ready to use are required. In a professional format of a box of 12 units, it is the ideal choice for stock management in operating theatres, ophthalmology clinics and purchasing centres.

2. Technical explanation of the material and procedure

Polyglactin 910 (PGLA) is a synthetic copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided, non-channeled multifilament structure that provides great flexibility, smooth passage through tissue and excellent knotting behaviour. Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, over an interval of 56 to 72 days, which guarantees a progressive, constant and predictable mass loss. It maintains a tensile strength retention of 75 % at 2 weeks, 50 % at 3 weeks and 30 % at 4 weeks, a sufficient period for the healing of most soft tissues. The thread, violet and non-channeled, offers optimal visibility on the surgical field. The 1/2 circle needle with cylindrical body and Ultra Plus conical point (designation HRP17) is indicated for medium and delicate tissues: its conical profile passes through with less resistance and without cutting effect on adjacent tissue, being ideal for ophthalmic procedures and approximation of loose tissues.

3. Technical Specifications

3.1. General characteristics

Characteristic Specification
Reference / SKU P1L18HRP1730-2
Brand / Quality Premisut – Prime
Suture type Absorbable multifilament
Material Polyglactin 910 (PGLA)
Composition Copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament, non-ribbed
USP size 3/0
Thread length 2×70 cm (double needle)
Thread colour Violet
Needle shape 1/2 circle
Needle body Cylindrical
Needle tip Conical Ultra Plus (Taperpoint)
Needle size 17 mm (HRP17)
Sterilisation Ethylene oxide (EO)
Tissue reaction Minimal
Presentation Box of 12 units
Minimum order 10 boxes

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption method Hydrolysis
Absorption time 56 – 72 days
Tensile strength at 2 weeks 75 %
Tensile strength at 3 weeks 50 %
Tensile strength at 4 weeks 30 %
Knot tying Excellent safety
Indications Tissue approximation, ligatures and ophthalmic surgery

3.3. Indications for use

  • Approximation of soft tissues.
  • Ligatures and internal closures.
  • Ophthalmic surgery and precision techniques.
  • Single use, not re-sterilisable.

4. Equivalences and Cross-References

Polyglactin 910 (PGLA) is one of the most widespread synthetic absorbable multifilament sutures on the market. From a clinical point of view, this Premisut Prime reference is comparable to the Vicryl / Vicryl Plus line from Ethicon (Johnson & Johnson), to Safil from B. Braun, to Polysorb from Medtronic/Covidien and to the polyglactin 910 ranges from SMI (Surgicryl), which facilitates approval in operating theatre protocols and hospital tenders. The 1/2 circle needle format with cylindrical body and 17 mm conical point corresponds to the classic pattern of small-format taper needles used in ophthalmic surgery and delicate tissues. Within the Cahnos catalogue, the single-needle version of the same profile, gauge and colour is reference P1L18HRP1730, while its equivalent in colourless thread with identical configuration is P1L28HRP1730.

5. Selection tips and variants of interest

The double needle configuration of this reference (2×70 cm, USP 3/0) is very useful in precision ophthalmic surgery and in procedures where two mounted threads with the same HRP17 needle with Ultra Plus conical point are needed. For the same needle profile in other gauges, Cahnos offers the variants P1L18HRP1710 (USP 0), P1L18HRP1720 (USP 2/0), P1L18HRP1740 (USP 4/0), P1L18HRP1750 (USP 5/0) and P1L18HRP1760 (USP 6/0), all with violet thread of 70 cm and box of 12 units. If a shorter needle of the same profile is required, reference P1L18HRP1330 (Ultra Plus conical point of 13 mm, USP 3/0) is the ideal alternative. For healing that requires earlier absorption, the fast-absorbing polyglactin 910 range may be considered. It is recommended to confirm the gauge and needle configuration according to the specialty and type of tissue before placing the order; consult your Cahnos advisor for minimum order conditions and B2B rates for purchasing centres and hospitals.

Additional information

Product line

Premisut – Prime

Material

Polyglactin 910 (PGLA)

Composition

Copolymer 90 % glycolide / 10 % L-lactide

Structure

Braided multifilament, non-ribbed

Needle size

17 mm (HRP17)

Needle body

Cylindrical

Needle tip

Conical Ultra Plus (Taperpoint)

Thread length

2×70 cm (double needle)

Sterilisation

Ethylene oxide (EO)

Tissue reaction

Minimal

Presentation

Box of 12 units

Minimum order

10 boxes

Indications

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

2xHRP 17 prime, HRP 17

Usp

3/0

Color

Violet

Medida de hilo

2 × 70 cm, 70 cm

Tipo de aguja

Cylindrical, Cylindrical flat tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 Premisut Prime – Double Needle 1/2 Circle Cylindrical Body Conical Point Ultra Plus 17 mm (HRP17), USP 3/0, Violet, 2×70 cm – Box of 12 units | Ref. P1L18HRP1730-2”

Your email address will not be published. Required fields are marked *