Description
1. Product Presentation
The absorbable multifilament suture of Polyglactin 910 (PGLA) from Cahnos, within the range Premisut Prime and with the reference P1L18HRP1730, is the synthetic reabsorbable solution designed for the professional who demands predictable behaviour, excellent tensile strength and great security in knot tying. Its ½ circle needle with cylindrical body and Ultra Plus conical point of 17 mm (HRP17) offers smooth and controlled penetration in soft tissues, minimising tissue trauma. It is the ideal choice for tissue approximation, ligatures and ophthalmic surgery, in professional format of box of 12 units, ideal for stock management in operating theatres, ophthalmic clinics and purchasing centres.
2. Technical explanation of the material and procedure
Polyglactin 910 (PGLA) is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure that provides great flexibility, smooth passage through tissue and excellent knot-tying behaviour. Its absorption occurs by hydrolysis, not by enzymatic action, over an interval of 56 to 72 days, which guarantees a progressive, constant and predictable loss of mass. It maintains a tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks, a sufficient period for the healing of most soft tissues. The thread, violet in colour and without channel, offers optimal visibility on the surgical field. The ½ circle needle with cylindrical body and Ultra Plus conical point (designation HRP17) is especially indicated for tissues of medium and delicate consistency: its conical profile passes through with less resistance and without cutting effect on adjacent tissue, being ideal for ophthalmic procedures and approximation of lax tissues.
3. Technical Specifications
| Reference | P1L18HRP1730 |
| Brand / Quality | Premisut – Prime |
| Material | Polyglactin 910 (PGLA) – copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament |
| USP size | 3/0 |
| Thread length | 70 cm |
| Colour | Violet, without channel (non-channeled) |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Conical Ultra Plus (Taperpoint) |
| Needle size | 17 mm (HRP17) |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Minimum order | 10 boxes |
Absorption profile and strength retention
| Tensile strength retention at 2 weeks | 75 % |
| Tensile strength retention at 3 weeks | 50 % |
| Tensile strength retention at 4 weeks | 30 % |
| Total absorption by hydrolysis | 56 – 72 days |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
4. Equivalences and Cross-References
Polyglactin 910 (PGLA) is one of the most widely used synthetic absorbable sutures on the market, so this Premisut Prime reference is perfectly comparable from a clinical point of view with the Vicryl® line from Ethicon (Johnson & Johnson), with Safil® from B. Braun, with Polysorb® from Medtronic/Covidien and with the polyglactin 910 ranges from SMI (Surgicryl), which facilitates approval in operating theatre protocols. As for the needle, the ½ circle format with cylindrical body and conical point of 17 mm corresponds to the classic pattern of small-format taper-type needles used in ophthalmic surgery and delicate tissues. Within the Cahnos catalogue, the reference P1L18HRP1730 is positioned as a direct alternative in box format of 12 units for tenders and hospital supply; its equivalent in colourless thread is P1L28HRP1730.
5. Selection tips and variants of interest
For the same HRP17 needle profile in other gauges, Cahnos offers the variants P1L18HRP1710 (USP 0), P1L18HRP1720 (USP 2/0), P1L18HRP1740 (USP 4/0), P1L18HRP1750 (USP 5/0) and P1L18HRP1760 (USP 6/0), all with violet thread of 70 cm and box of 12 units. For precision ophthalmic surgery with double needle, the variant P1L18HRP1730-2 (2×70 cm, USP 3/0) is very useful. If a shorter needle of the same profile is required, the reference P1L18HRP1330 (Ultra Plus conical point of 13 mm, USP 3/0) is the ideal alternative. It is recommended to confirm the gauge and needle configuration according to the specialty and type of tissue before placing the order; consult your Cahnos advisor for minimum order conditions and B2B rates for purchasing centres and hospitals.