We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture | 1/2 Circle Cylindrical HRP 36 mm Needle Trocar Ultra Plus Point | USP Gauge 1, Violet Thread 70 cm | Box of 12 units – Ref. P1L18RHRP3601

43,48 €

Prime quality absorbable multifilament Polyglactin 910 (PGLA) suture, reference P1L18RHRP3601, mounted with a 1/2 circle cylindrical body HRP 36 mm needle and Trocar Ultra Plus point, USP gauge 1 and 70 cm violet thread with high visibility in the surgical field. Predictable absorption by hydrolysis between 56 and 72 days and tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide and single-use, indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units, ready for the operating theatre and hospital supply.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18RHRP3601

Description

1. Commercial presentation

At Cahnos we offer you the Prime quality absorbable multifilament Polyglactin 910 (PGLA) suture, reference P1L18RHRP3601, designed for the professional who demands reliable, manageable and predictable performance in the operating theatre. This presentation combines a 1/2 circle cylindrical body HRP 36 mm needle with a Trocar Ultra Plus point, USP gauge 1 and a 70 cm violet multifilament thread with high visibility on tissue. It is an excellent option for soft tissue approximation, ligatures and ophthalmic surgery, with predictable absorption that avoids the need for later removal. It is supplied in a box of 12 units, sterile by ethylene oxide and ready for immediate use in the operating theatre, private clinics and hospital purchasing centres.

2. Technical explanation of the material and procedure

Polyglactin 910 (PGLA) is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, structured as a braided and coated multifilament. This configuration provides great flexibility, low memory, smooth passage through tissue and secure, stable knot tying, with high initial tensile strength, an attribute especially valued in USP gauge 1. Its absorption occurs by hydrolysis over an interval of 56 to 72 days, with progressive and predictable loss of strength, without depending on the patient’s enzymatic activity and with minimal tissue reaction.

The 1/2 circle cylindrical body needle with Trocar Ultra Plus point (designation HRP 36) penetrates tissues with lower penetration resistance and without cutting effect on adjacent tissue, minimising trauma and improving control in delicate areas such as the ocular surface and lax tissues. The violet colour of the thread ensures optimal visibility throughout the procedure. The product is supplied sterile by ethylene oxide (EO) and is single-use.

3. Technical Specifications

Main characteristics of reference P1L18RHRP3601:

Reference P1L18RHRP3601
Brand / Quality Premisut – Prime
Material Polyglactin 910 (PGLA): 90% glycolide / 10% L-lactide
Thread structure Coated braided multifilament
USP / metric gauge 1 (metric 4)
Thread length 70 cm
Thread colour Violet
Needle shape 1/2 circle
Needle body Cylindrical
Needle size 36 mm (HRP 36 Prime)
Needle tip Trocar Ultra Plus (Taperpoint type / conical point)
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (EO), sterile single-use
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units

Tensile strength retention and absorption profile:

Period Tensile strength retention
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 30% of initial tensile strength
Complete absorption 56 – 72 days by hydrolysis

4. Equivalences and Cross-References

Polyglactin 910 is one of the classic compositions in the market for synthetic absorbable multifilament sutures of medium absorption. This Prime reference from Cahnos is clinically equivalent, both in chemical composition and in absorption profile (56-72 days) and tensile strength retention, to the Vicryl™ lines from Ethicon (Johnson & Johnson), to the Safil range from B. Braun, to Polysorb from Medtronic/Covidien and to the polyglactin 910 ranges from SMI (Surgicryl). The HRP needle with Trocar Ultra Plus point is functionally equivalent to the reinforced conical needles with penetration point (taperpoint type) used by the main manufacturers for resistant but delicate tissues.

Within the Cahnos catalogue, this reference shares a family with the PGLA Prime line with HRP 36 mm needle: the equivalent colourless version P1L28RHRP3601 (USP 1, 70 cm), P1L18RHRP3610 (USP 0, violet, 70 cm), P1L18RHRP3620 and P1L13RHRP3620 (USP 2/0, 70 and 90 cm), P1L18RHRP3630 and P1L13RHRP3630 (USP 3/0), as well as the other colourless version P1L28RHRP3620.

5. Selection tips and variants of interest

USP gauge 1 with HRP 36 mm needle and Trocar Ultra Plus point is especially indicated for approximation of tissues under tension, ligatures and fixation techniques in general and ophthalmic surgery; for more delicate planes consider the lower gauges (USP 0, 2/0 or 3/0) of the same family. Choose the thread length (70 or 90 cm) according to the number of stitches planned and the colour (violet or colourless) according to the visibility required in the surgical field. For fibrous and less lax tissues, such as the sclera, the Trocar Ultra Plus point provides an atraumatic and controlled passage. If you prefer a needle with a smaller radius, the HRP 30 mm (P1L18RHRP3010) or HRP 26 mm (P1L18RHRP2601) variants are available. As it is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight, inside its sterile packaging until use. Consult our technical-commercial team for special conditions by volume and hospital supply contracts.

Additional information

Material

Polyglactin 910 (PGLA): 90% glycolide / 10% L-lactide

Thread structure

Coated braided multifilament

USP size

1 (metric 4)

Needle body

Cylindrical

Needle size

36 mm (HRP 36 Prime)

Needle tip

Trocar Ultra Plus (Taperpoint type / conical point)

Tensile strength retention

75 % at 2 weeks; 50 % at 3 weeks; 30 % at 4 weeks

Sterilisation

Ethylene oxide (EO), single-use

Quality

Prime (Premisut)

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Medida de aguja

HRP 36

Usp

1

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical flat tip, Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture | 1/2 Circle Cylindrical HRP 36 mm Needle Trocar Ultra Plus Point | USP Gauge 1, Violet Thread 70 cm | Box of 12 units – Ref. P1L18RHRP3601”

Your email address will not be published. Required fields are marked *