We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Multifilament PGLA Polyglactin 910 Prime Suture | 1/2 Circle Cylindrical HRP 30 mm Needle Trocar Ultra Plus Point | USP Gauge 2/0, Violet Thread 70 cm – Box of 12 units (Ref. P1L18RHRP3020)

43,48 €

Absorbable multifilament suture of polyglactin 910 (PGLA) Prime quality, reference P1L18RHRP3020. Mounted with a 1/2 circle cylindrical body HRP 30 mm needle and Trocar Ultra Plus point (reinforced conical point). USP gauge 2/0, violet braided thread of 70 cm with high visibility in the surgical field. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. Sterile by ethylene oxide, single-use; indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18RHRP3020

Description

1. Product Presentation

At Cahnos we offer you the Prime-quality absorbable multifilament polyglactin 910 (PGLA) suture, reference P1L18RHRP3020, designed for the professional who demands reliable, manageable and predictable performance in the operating theatre. This presentation combines a 1/2 circle cylindrical body HRP 30 mm needle with a Trocar Ultra Plus point, a USP 2/0 gauge and a violet braided thread of 70 cm with high visibility on tissue. It is an excellent option for approximating soft tissues, ligatures and ophthalmic surgery, with fully predictable absorption that avoids the need for later removal. It is supplied in a box of 12 units, sterile by ethylene oxide and ready for immediate use in hospitals, private clinics, operating theatres and purchasing centres.

2. Technical explanation of the material and procedure

Polyglactin 910 (PGLA) is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided and coated multifilament structure. This configuration provides great flexibility, low memory, smooth passage through tissue and secure, stable knot tying, with minimal tissue reaction. Its absorption occurs by hydrolysis over a period of 56 to 72 days, ensuring a progressive and predictable loss of strength, independent of the patient’s enzymatic activity. The 1/2 circle cylindrical body needle with Trocar Ultra Plus point (designation HRP 30 Prime) penetrates tissues with lower penetration resistance and without a cutting effect on adjacent tissue, minimising surgical trauma and improving control in delicate areas such as the ocular surface and lax tissues. The violet colour of the thread ensures optimal visibility throughout the procedure. The product is sterilised by ethylene oxide (EO) and is single-use.

3. Technical Specifications

Main features of reference P1L18RHRP3020:

Characteristic Specification
Reference P1L18RHRP3020
Brand / Quality Premisut – Prime
Material Polyglactin 910 (PGLA): copolymer 90% glycolide / 10% L-lactide
Thread structure Braided and coated multifilament
USP / metric gauge 2/0 (metric 3)
Thread length 70 cm
Thread colour Violet (colourless version available in the family)
Needle shape 1/2 circle
Needle body Cylindrical
Needle size 30 mm (HRP 30 Prime)
Needle tip Trocar Ultra Plus (Taperpoint type / reinforced conical point)
Sterilisation Ethylene oxide (EO), sterile, single-use
Absorption By hydrolysis, between 56 and 72 days
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units

Absorption and tensile strength retention profile:

Period Tensile strength retention
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 30% of initial tensile strength
Total absorption 56 – 72 days by hydrolysis

4. Equivalences and Cross-References

Polyglactin 910 is the classic composition of synthetic absorbable multifilament sutures with medium absorption. This Prime reference is clinically equivalent, both in chemical composition and in absorption profile (56-72 days) and tensile strength retention, to the Vicryl™ / Vicryl Plus lines (Ethicon – Johnson & Johnson), Safil (B. Braun), Polysorb (Medtronic/Covidien) and Surgicryl (SMI). The HRP needle with Trocar Ultra Plus point is functionally equivalent to the reinforced conical needles with penetration point (taperpoint type) used by the main manufacturers for resistant but delicate tissues. Within the Cahnos catalogue, this reference shares a family with the variants with 30 mm HRP needle: P1L18RHRP3030 (gauge 3/0, violet, 70 cm) and P1L18RHRP3010 (USP gauge 0, violet, 70 cm), as well as P1L12RHRP3001 (USP gauge 1, 75 cm thread). For other needle radii with the same gauge 2/0, see P1L18RHRP3620 (HRP 36 mm), P1L18RHRP4020 (HRP 40 mm) and P1L18RHRP2620 (HRP 26 mm); for 90 cm thread, P1L13RHRP3620 is available.

5. Selection tips and variants of interest

The USP 2/0 gauge with a 30 mm HRP needle and Trocar Ultra Plus point offers an optimal balance between strength and delicacy, suitable for approximating soft tissues, precision ligatures, fine tissue planes and ophthalmic surgery. Consider these criteria when selecting your suture:

  • Gauge: 2/0 is ideal for medium-resistance tissues; for more superficial planes consider 3/0 (P1L18RHRP3030) and for greater traction, USP 0 (P1L18RHRP3010) or USP 1 (P1L12RHRP3001).
  • Needle radius: check HRP 26, 30, 36 or 40 mm according to the depth and surgical area; the Trocar Ultra Plus point is especially suitable for the sclera and fibrous tissues.
  • Thread length: choose 70, 75 or 90 cm depending on the number of stitches planned.
  • Colour: violet offers maximum visibility; if you prefer discretion, colourless versions are available in the family (P1L28RHRP3601 and P1L28RHRP3620).

As it is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. Contact our technical-commercial team for special volume conditions and hospital supply contracts.

Additional information

Reference

P1L18RHRP3020

Product line

Premisut – Prime

Material

Polyglactin 910 (PGLA) – 90% glycolide / 10% L-lactide

Thread structure

Braided and coated multifilament

USP size

2/0 (metric 3)

Needle body

Cylindrical

Needle size

30 mm (HRP 30 Prime)

Needle tip

Trocar Ultra Plus (Taperpoint / reinforced conical point)

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Indications

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

HRP 30

Usp

2/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical flat tip, Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Polyglactin 910 Prime Suture | 1/2 Circle Cylindrical HRP 30 mm Needle Trocar Ultra Plus Point | USP Gauge 2/0, Violet Thread 70 cm – Box of 12 units (Ref. P1L18RHRP3020)”

Your email address will not be published. Required fields are marked *