Description
1. Commercial Introduction
The absorbable multifilament suture of Polyglactin 910 (PGLA) reference P1L12HS2202H is the reference technical solution for the professional seeking a surgical thread with predictable behaviour, excellent handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery. Its ½ circular needle with triangular reverse cutting point of 22 mm in Heavy version (HS 22) offers firm and controlled penetration, ideal for consistent and non-compliant tissues, while the 75 cm violet fluted thread guarantees optimal visibility over the surgical field and smooth sliding during suturing.
It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B procurement of operating theatres, ophthalmic clinics and purchasing centres. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, which ensures the continuous supply of your healthcare centre.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that favours the passage of the thread through the tissue, smooth handling and firm, secure knot tying, even in larger diameter gauges such as USP 2 (metric 5).
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The Heavy version of the HS 22 needle has reinforced triangular reverse cutting body and point, designed to penetrate firm and dense tissues with controlled trauma and without tearing, which is why it is especially indicated in tissue approximation, ligatures and ophthalmic and general surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L12HS2202H
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Range / Quality | PRIME (Prime Heavy) |
| Gauge | USP 2 (metric 5) |
| Thread colour | Violet |
| Needle shape | ½ circle, triangular reverse cutting body and point |
| Needle size | HS 22 Heavy (22 mm) |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L12HS2202H |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days by hydrolysis |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament Polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratorio Aragó (Premisut range) | Polyglactin 910 braided coated multifilament |
Within the Cahnos catalogue, its direct equivalent in needle format within the polyglycolic acid (PGA) family is reference AMP112HS2202H (triangular HS 22 Heavy needle, USP 2, violet, 75 cm, Prime range), recommended when an absorption profile of 60 to 90 days is preferred. The Normal quality version of this same PGLA format is processed as 1L12HS2202H, and its colourless equivalent as 1L28HS2210H.
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the gauge needed according to the anatomical area. USP 2 (metric 5) gauge is indicated for tissues requiring greater initial resistance: deep planes, fascia, aponeurosis, high-tension closures and ligatures. The triangular reverse cutting needle in Heavy version (HS 22) is especially recommended when firm tissues need to be penetrated without tearing, with a clean and precise needle passage.
| Reference | Variant |
|---|---|
| 1L12HS2202H | PGLA Normal quality, same HS22 Heavy needle, USP 2, violet, 75 cm (economical alternative) |
| 1L28HS2210H | PGLA HS22 Heavy, USP 0, colourless, 70 cm (same needle, smaller gauge) |
| 1L18HS2230 | PGLA HS22, USP 3/0, violet, 70 cm (delicate tissues) |
| 1L28HS2230 | PGLA HS22, USP 3/0, colourless, 70 cm (maximum aesthetic discretion) |
| P1L18HS2220 | PGLA Prime HS22, USP 2/0, violet, 70 cm (superior range, fine gauge) |
| 1L13HS3602 | PGLA HS36, USP 2, violet, 90 cm (longer needle, same gauge) |
| 1L13HS4002 | PGLA HS40, USP 2, violet, 90 cm (greater needle and thread length) |
If you need longer force retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.