Description
1. Commercial Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range, reference P1L22HS2220, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.
Its ½ circle needle with reverse cutting triangular point of 22 mm (HS 22) ensures firm, controlled penetration even in dense, non-compliant tissues, while the undyed, grooved 75 cm thread offers smooth passage during suturing. It is a synthetic absorbable medical device, sterile, single-use and with an excellent quality-price ratio.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 2/0.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with reverse cutting triangular point penetrates firm tissues with controlled trauma, avoiding tearing, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L22HS2220
| Characteristic | Specification |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (Premisut range) |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless (also available in violet) |
| Needle shape | ½ circle, triangular reverse cutting body and point |
| Needle size | HS 22 mm |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units (minimum order of 30 boxes) |
| Reference (SKU) | P1L22HS2220 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratorio Aragó (Premisut range) | Braided multifilament polyglactin 910 with ½ circle needles (C, TC and HS series) |
Within the Cahnos catalogue, its direct equivalent by needle configuration and material in the polyglycolic acid (PGA) family is reference AMP122HS2220 (HS 22 mm triangular needle, USP 2/0, undyed, 75 cm), recommended when an absorption profile of 60 to 90 days is preferred. In the same PGLA Prime range with similar configurations are P1L18HS2220 (HS 22 mm triangular needle, USP 2/0, violet, 70 cm), P1L12HR2220 (HR 22 mm cylindrical needle, USP 2/0, violet, 75 cm) and P1L28HR2220 (HR 22 mm cylindrical needle, USP 2/0, undyed, 70 cm).
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the gauge needed according to the anatomical area. USP 2/0 (metric 3) gauge is indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in ophthalmic surgery. The reverse cutting triangular point needle (HS 22) is especially recommended for firm, non-compliant tissues, where the needle passage must be clean and without tearing.
| Reference | Variant |
| P1L22HS2220 | PGLA Prime USP 2/0, HS 22 mm triangular needle, undyed, 75 cm (current product) |
| P1L18HS2220 | PGLA Prime USP 2/0, HS 22 mm triangular needle, violet, 70 cm (dyed thread for greater visibility) |
| P1L28HS2620 | PGLA Prime USP 2/0, HS 26 mm triangular needle, undyed, 70 cm (longer needle) |
| P1L22DS2420 | PGLA Prime USP 2/0, 3/8 triangular DS 24 mm needle, undyed, 75 cm (ophthalmic format) |
| AMP122HS2220 | PGA Prime USP 2/0, HS 22 mm triangular needle, undyed, 75 cm (60-90 day absorption) |
If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews