Absorbable Multifilament Suture PGLA Polyglactin 910 Prime | 1/2 Circle Reverse Cutting Triangular Point Needle HS 22 mm | USP 2/0 (Metric 3) Gauge | Undyed Grooved Thread 75 cm | Ref. P1L22HS2220 – Box of 12 units

Original price was: 39,60 €.Current price is: 32,60 €.

Absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range, reference P1L22HS2220, with a ½ circle reverse cutting triangular point needle of 22 mm (HS 22), USP 2/0 (metric 3) gauge and undyed grooved 75 cm thread. Synthetic copolymer of 90% glycolide and 10% L-lactide, with predictable absorption by hydrolysis in 56-72 days and tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. Sterile by ethylene oxide, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units, with a minimum order of 30 boxes for institutional B2B supply.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L22HS2220

Description

1. Commercial Introduction

The absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range, reference P1L22HS2220, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.

Its ½ circle needle with reverse cutting triangular point of 22 mm (HS 22) ensures firm, controlled penetration even in dense, non-compliant tissues, while the undyed, grooved 75 cm thread offers smooth passage during suturing. It is a synthetic absorbable medical device, sterile, single-use and with an excellent quality-price ratio.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 2/0.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with reverse cutting triangular point penetrates firm tissues with controlled trauma, avoiding tearing, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference P1L22HS2220

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Quality Prime (Premisut range)
Gauge USP 2/0 (metric 3)
Thread colour Colourless (also available in violet)
Needle shape ½ circle, triangular reverse cutting body and point
Needle size HS 22 mm
Thread length 75 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units (minimum order of 30 boxes)
Reference (SKU) P1L22HS2220

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.

4. Equivalences and Cross-References

This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
Laboratorio Aragó (Premisut range) Braided multifilament polyglactin 910 with ½ circle needles (C, TC and HS series)

Within the Cahnos catalogue, its direct equivalent by needle configuration and material in the polyglycolic acid (PGA) family is reference AMP122HS2220 (HS 22 mm triangular needle, USP 2/0, undyed, 75 cm), recommended when an absorption profile of 60 to 90 days is preferred. In the same PGLA Prime range with similar configurations are P1L18HS2220 (HS 22 mm triangular needle, USP 2/0, violet, 70 cm), P1L12HR2220 (HR 22 mm cylindrical needle, USP 2/0, violet, 75 cm) and P1L28HR2220 (HR 22 mm cylindrical needle, USP 2/0, undyed, 70 cm).

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the gauge needed according to the anatomical area. USP 2/0 (metric 3) gauge is indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in ophthalmic surgery. The reverse cutting triangular point needle (HS 22) is especially recommended for firm, non-compliant tissues, where the needle passage must be clean and without tearing.

Reference Variant
P1L22HS2220 PGLA Prime USP 2/0, HS 22 mm triangular needle, undyed, 75 cm (current product)
P1L18HS2220 PGLA Prime USP 2/0, HS 22 mm triangular needle, violet, 70 cm (dyed thread for greater visibility)
P1L28HS2620 PGLA Prime USP 2/0, HS 26 mm triangular needle, undyed, 70 cm (longer needle)
P1L22DS2420 PGLA Prime USP 2/0, 3/8 triangular DS 24 mm needle, undyed, 75 cm (ophthalmic format)
AMP122HS2220 PGA Prime USP 2/0, HS 22 mm triangular needle, undyed, 75 cm (60-90 day absorption)

If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA) – copolymer 90% glycolide / 10% L-lactide

Structure

Multifilament braided fluted

Gauge

USP 2/0 (metric 3)

Needle shape

1/2 circle, triangular reverse cutting body and point

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units (minimum order 30 boxes)

Medida de aguja

HS 22

Usp

2/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)