We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 Needle 1/2 Circle Triangular Reverse Cutting HS36mm USP 2 Violet 90cm Prime

Original price was: 39,90 €.Current price is: 32,60 €.

Synthetic absorbable multifilament suture of Polyglactin 910 (PGLA) from the Prime line, with a 1/2 circle needle with reverse cutting triangular point of 36 mm (HS36), USP size 2 and fluted violet thread of 90 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. Sterile by ethylene oxide, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L13HS3602. Price per box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L13HS3602

Description

Absorbable Suture PGLA Polyglactin 910 Prime

1. Product Presentation

The absorbable multifilament suture PGLA Polyglactin 910 from the Prime line is the professional solution your operating theatre needs for procedures that demand reliability, manageability and fully predictable absorption. With a 1/2 circle needle with reverse cutting triangular point of 36 mm, USP size 2, fluted violet thread of 90 cm and reference P1L13HS3602, this suture offers consistent clinical performance in tissue approximation, ligatures and ophthalmic surgery. Supplied in a box of 12 units, with a minimum order of 30 boxes, it is a high-quality alternative with an excellent cost-performance ratio for hospitals, clinics and purchasing centres.

2. Technical explanation

Polyglactin 910 (PGLA) is a biocompatible synthetic copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure provides great flexibility and exceptional handling, while its fluted finish favours the sliding of the thread through tissues and secure knot tying. Absorption occurs by hydrolysis over an interval of 56 to 72 days, with a gradual and predictable loss of tensile strength, allowing the edges to be kept in apposition during the critical phase of healing. The 1/2 circle needle profile with reverse cutting triangular point is designed to penetrate dense and non-compliant tissues with minimal trauma, while the violet colour ensures excellent visibility of the thread on the surgical field. The product is supplied sterile, sterilised by ethylene oxide.

3. Technical Specifications

Reference P1L13HS3602
Material Polyglactin 910 (PGLA): copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Colour Violet
Gauge USP 2
Thread length 90 cm
Needle shape ½ circle
Needle tip Triangular reverse cutting (reverse cutting)
Needle size 36 mm (HS36)
Absorption By hydrolysis, between 56 and 72 days
Retained tensile strength 75 % at 2 weeks | 50 % at 3 weeks | 30 % at 4 weeks
Sterilisation Ethylene oxide
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units (minimum order: 30 boxes)

4. Equivalences and Cross-References

Polyglactin 910 is one of the most well-established synthetic absorbable suture raw materials on the market, a clinical equivalent of reference products such as Vicryl (Ethicon / Johnson & Johnson), Polysorb (Covidien / Medtronic) or Safil (B. Braun), all based on the same copolymer of glycolide and lactide. This reference from the Prime line shares configuration with the rest of the sizes of the HS36 family (1/2 circle reverse cutting triangular needle of 36 mm, 90 cm thread): P1L13HS3601 (USP 1), P1L13HS3610 (USP 0) and P1L13HS3620 (USP 2/0). It can also be replaced by the version in polyglycolic acid (PGA) of the same format, references AMP113HS3601 and AMP113HS3602.

5. Selection tips and variants of interest

To choose the appropriate size, take into account the tension the suture will bear and the anatomical area: thick sizes such as USP 2 are ideal for tissues requiring high tensile strength (aponeurosis, abdominal wall, ligatures of medium-sized vessels), while smaller sizes such as USP 2/0 or USP 0 are reserved for more delicate tissues. If the procedure requires less passage trauma in soft tissues, consider the variant with cylindrical needle HR36 (references P1L13HR3601, P1L13HR3602 and P1L13HR3620) or the colourless version P1L23HR3602. For ophthalmic surgery we also have the presentation with 3/8 circle triangular needle of 36 mm (DS36, reference P1L12DS3602). Consult our technical-commercial team to confirm the exact equivalence with the reference you usually use and optimise your order.

Additional information

Reference

P1L13HS3602

Material

Polyglactin 910 (PGLA) – copolymer of 90 % glycolide and 10 % L-lactide

Thread structure

Multifilament braided fluted

Needle tip

Triangular reverse cutting (reverse cutting)

Needle size

36 mm (HS36)

Tensile strength

75 % (2 weeks), 50 % (3 weeks), 30 % (4 weeks)

Sterilisation

Ethylene oxide

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HS 36

Usp

2

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 Needle 1/2 Circle Triangular Reverse Cutting HS36mm USP 2 Violet 90cm Prime”

Your email address will not be published. Required fields are marked *