We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA Polyglactin 910 Prime Suture 2/0 1/2 Circle Reverse Cutting Triangular Needle HS 36 mm Colourless 90 cm – Ref. P1L23HS3620

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament PGLA (Polyglactin 910) Prime suture with a ½ circle reverse cutting triangular point needle of 36 mm (HS 36), USP 2/0 gauge and 90 cm colourless fluted thread. Copolymer of 90% glycolide and 10% L-lactide, with predictable absorption by hydrolysis in 56-72 days and tensile strength retention of 75% at 2 weeks. Sterile by ethylene oxide, minimal tissue reaction and excellent knot security for tissue approximation, ligatures and ophthalmic surgery. Reference P1L23HS3620, presentation in a box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L23HS3620

Description

1. Introduction

The absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range is the reference solution in the operating theatre for professionals seeking a thread with reliable, predictable, high-quality performance in soft tissue approximation, ligatures and ophthalmic surgery. Its ½ circle reverse cutting triangular point needle, 36 mm (HS 36), ensures precise penetration even in firm tissues, while the 90 cm colourless fluted thread offers excellent visibility of the surgical field and exceptional handling with every stitch.

Manufactured to strict quality standards for the B2B channel, it combines minimal tissue reaction with excellent tensile strength and optimal knot security, ensuring consistent clinical outcomes in every procedure. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, configured as a coated braided multifilament structure with a fluted (ribbed) finish. This structure provides a regular surface that favours thread glide through tissue, smooth handling and firm, secure knot tying.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture suitable for tissues requiring wound support during the first weeks of healing. The ½ circle needle with reverse cutting triangular point (Reverse Cutting) penetrates firm, dense tissues with controlled trauma, avoiding tearing. The product is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference P1L23HS3620

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide
Thread structure Braided coated multifilament, fluted finish
Gauge USP 2/0 (metric 3)
Colour Undyed (also available in violet)
Needle shape ½ circle
Tip type Triangular reverse cutting (Reverse Cutting)
Needle size HS 36 mm
Thread length 90 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (EO)
Tissue reaction Minimal
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) P1L23HS3620

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75%
3 weeks 50%
4 weeks 30%

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.

4. Equivalences and Cross-References

This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910)
B. Braun Safil (braided polyglactin 910)
Medtronic Absorbable braided polyglactin 910 range
Aragó Laboratory (Aragó Sutures) Polyglactin 910 range with 1/2 circle needles (C / TC / HS series)

Within the Cahnos catalogue, its direct equivalent in the same PGLA Prime family with a conical point is reference P1L23HR3620 (cylindrical HR 36 mm). In the polyglycolic acid (PGA) family, the equivalents in structure and needle are AMP123HS3620 (triangular HS 36 mm, colourless) and AMP123HR3620 (cylindrical HR 36 mm), ideal when an absorption profile of 60 to 90 days is preferred.

5. Selection tips and variants of interest

To choose the most suitable suture, take into account the wound support time required by the tissue to be sutured and the gauge needed according to the anatomical area. Polyglactin 910 offers an excellent balance between initial strength and predictable absorption for soft tissues with healing of 2 to 4 weeks. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis), while the cylindrical (HR) variant is more atraumatic in delicate tissues.

Reference Variant
P1L23HS3620 PGLA Prime USP 2/0, triangular HS 36 mm needle, colourless, 90 cm (current product)
P1L23HR3620 PGLA Prime USP 2/0, cylindrical HR 36 mm needle (conical point, more atraumatic)
P1L13HS3610 PGLA Prime USP 0, HS 36 mm needle, violet, 90 cm (larger gauge)
AMP123HS3620 PGA Prime USP 2/0, HS 36 mm needle, colourless, 90 cm (absorption 60-90 days)
AMP113HS3620 PGA Prime USP 2/0, HS 36 mm needle, violet, 90 cm
AMP2L23HS3620 PGLAR Polyglactin 910 Rapid, HS 36 mm needle, 2/0, colourless, 90 cm (absorption 40-45 days)

If you require longer strength retention or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos, with absorption of 180 to 210 days. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Thread structure

Braided coated multifilament, fluted finish

Gauge

USP 2/0 (metric 3)

Tip type

Triangular reverse cutting (Reverse Cutting)

Tensile strength

75% at 2 weeks, 50% at 3 weeks, 30% at 4 weeks

Sterilisation

Ethylene oxide (EO)

Tissue reaction

Minimal

Presentation

Box of 12 units

Minimum order

30 boxes

Indications

Tissue approximation, ligatures and ophthalmic surgery

Single-use

Yes, do not re-sterilise

Medida de aguja

HS 36

Usp

2/0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)