We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture – 1/2 Circle Reverse Cutting Triangular HS Needle 40 mm – USP 2/0 – Violet – Thread 70 cm – Ref. P1L18HS4020

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament polyglactin 910 (PGLA) suture from the Prime Premisut range, with ½ circle reverse cutting triangular body and point (HS) needle of 40 mm, USP gauge 2/0 and 70 cm violet braided thread with ribbed finish. Copolymer 90 % glycolide / 10 % L-lactide with predictable absorption by hydrolysis in 56-72 days and tensile strength retention of 75 % (2 weeks), 50 % (3 weeks) and 30 % (4 weeks). Sterile by ethylene oxide, minimal tissue reaction and excellent knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery. Reference P1L18HS4020, presentation in a box of 12 units. Minimum order: 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18HS4020

Description

1. Introduction

The Prime absorbable multifilament polyglactin 910 (PGLA) suture from the Premisut range is the reference solution in the operating theatre for professionals seeking reliable, predictable, high-quality performance in soft tissue approximation, ligatures and ophthalmic surgery. Its ½ circle needle with reverse cutting triangular body and point (HS) of 40 mm provides precise penetration even in firm or resistant tissues, while the 70 cm violet braided thread ensures excellent handling and optimal visibility of the surgical field.

Manufactured under strict quality standards, it combines minimal tissue reaction with excellent tensile strength and optimal knot security, ensuring consistency and clinical results in every procedure. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes to ensure continuous supply for your healthcare centre.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, configured in a braided multifilament structure with a ribbed finish. This structure provides a regular surface that favours thread sliding through tissue, excellent handling and firm, secure knot tying, with high initial tensile strength.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This tensile strength retention profile makes it ideal for tissues requiring wound support during the first weeks of healing. The ½ circle needle with reverse cutting triangular point allows penetration of firm tissues with controlled trauma, being especially recommended for tissue approximation, ligatures and ophthalmic surgery. The product is supplied sterile by ethylene oxide.

3. Technical Specifications

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 2/0
Colour Violet (also available colourless)
Needle ½ circle, reverse cutting triangular body and point (HS)
Needle size 40 mm
Thread length 70 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide
Presentation Box of 12 units
Reference (SKU) P1L18HS4020

Tensile strength retention profile:

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.

4. Equivalences and Cross-References

This multifilament polyglactin 910 suture is clinically in the same family as the reference synthetic absorbable braided sutures on the international market (polyglactin 910 type material, equivalent to lines such as Vicryl from Ethicon or Safil from B. Braun), commonly used in general surgery, gynaecology, urology and specialised surgery.

Within the Cahnos catalogue, its direct equivalent in PGA (polyglycolic acid) material, with the same 40 mm reverse cutting triangular needle, gauge 2/0 and 70 cm length, is reference AMP118HS4020, ideal when an absorption profile of 60 to 90 days is preferred. To configure the complete operating theatre range, it is recommended to combine this reference with the following variants of the same family:

Reference Variant
P1L18HS4020 PGLA Prime USP 2/0, HS needle 40 mm reverse cutting triangular, violet, 70 cm (current product)
P1L13HS4002 PGLA Prime USP 2, HS 40 mm triangular reverse cutting needle, violet, 90 cm
P1L18HR4030 PGLA Prime USP 3/0, HR needle 40 mm cylindrical, violet, 70 cm
P1L18FR4020 PGLA Prime USP 2/0, FR needle 40 mm cylindrical 5/8, violet, 70 cm
AMP118HS4020 PGA Prime USP 2/0, HS needle 40 mm reverse cutting triangular, violet, 70 cm

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. Polyglactin 910 offers an excellent balance between initial strength and predictable absorption for soft tissues with healing of 2 to 4 weeks. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing, while the cylindrical (HR) variant is more atraumatic in delicate tissues.

If you need longer strength retention or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos, with absorption of 180 to 210 days. For tissues with faster absorption needs, consult the rapid-absorption polyglactin 910 range or polyglycolic acid (PGA). All references are supplied in a box of 12 units, with a minimum order of 30 boxes to ensure continuous supply for your healthcare centre.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Needle type

1/2 circle, reverse cutting triangular body and point (HS)

Needle size

40 mm (HS 40 Prime)

Absorption mechanism

Hydrolysis, 56-72 days

Sterilisation

Ethylene oxide

Presentation

Box of 12 units

Minimum order

30 boxes

Indications

Tissue approximation, ligatures and ophthalmic surgery

Brand / Range

Premisut Prime

Medida de aguja

HS 40

Usp

2/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture – 1/2 Circle Reverse Cutting Triangular HS Needle 40 mm – USP 2/0 – Violet – Thread 70 cm – Ref. P1L18HS4020”

Your email address will not be published. Required fields are marked *