Description
1. Product Presentation
The absorbable multifilament PGLA polyglactin 910 suture from the Prime line is the professional solution your operating theatre needs for procedures that demand reliability, manageability and fully predictable absorption. With a ½ circular needle with reverse cutting triangular point of 36 mm, USP 1 gauge, 90 cm violet fluted thread and reference P1L13HS3601, this suture offers consistent clinical performance in tissue approximation, ligatures and ophthalmic surgery.
Supplied in boxes of 12 units, with a minimum order of 30 boxes, it constitutes a high-quality alternative with an excellent cost-performance ratio for hospitals, clinics and purchasing centres.
2. Technical explanation
Polyglactin 910 (PGLA) is a biocompatible synthetic copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure provides great flexibility and exceptional handling, while its fluted finish favours the sliding of the thread through tissues and secure knot tying.
Absorption occurs by hydrolysis over an interval of 56 to 72 days, with a gradual and predictable loss of tensile strength, allowing the edges to be kept in apposition during the critical phase of healing. The ½ circular needle profile with reverse cutting triangular point is designed to penetrate dense and non-compliant tissues with minimal trauma, while the violet colour ensures excellent visibility of the thread on the surgical field.
The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised. It presents minimal tissue reaction, excellent tensile strength and optimal knot tying.
3. Technical Specifications
3.1. General characteristics of reference P1L13HS3601
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (Premisut range) |
| Gauge | USP 1 (metric 4) |
| Colour | Violet |
| Needle shape | ½ circle |
| Tip type | Reverse cutting triangular |
| Needle size | HS 36 mm |
| Thread length | 90 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO) |
| Tissue reaction | Minimal |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L13HS3601 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units, with a minimum order of 30 boxes.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Polysorb (absorbable braided range of polyglactin 910) |
| Aragó Laboratory (Aragó Sutures) | Polyglactin 910 range with 1/2 circle needles (C / TC / HS series) |
Within the Cahnos catalogue, this reference from the Prime line shares configuration (½ circular reverse cutting triangular needle of 36 mm, 90 cm thread) with the rest of the gauges in the HS36 family: P1L13HS3602 (USP 2), P1L13HS3610 (USP 0) and P1L13HS3620 (USP 2/0). Its direct equivalent with a conical, more atraumatic point is reference P1L13HR3601 (cylindrical HR 36 mm, USP 1, violet, 90 cm). It can also be replaced by the polyglycolic acid (PGA) version of the same format, references AMP113HS3601 (USP 1) and AMP113HS3602 (USP 2).
5. Selection tips and variants of interest
To choose the appropriate gauge, take into account the tension the suture will bear and the anatomical area: USP 1 gauge (metric 4) is ideal for tissues with moderate-high tension, such as fascia, aponeurosis, abdominal wall and ligatures of medium-calibre vessels, while smaller gauges such as USP 0 or USP 2/0 are reserved for more delicate tissues and USP 2 for deep planes and high tension.
The reverse cutting triangular point needle is especially indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis). If the procedure requires less passage trauma in soft tissues, consider the variant with cylindrical HR36 needle (P1L13HR3601, P1L13HR3610 and P1L13HR3620) or the colourless version P1L23HR3602. For ophthalmic surgery we also have the presentation with a ⅜ circular triangular needle of 36 mm (DS36, reference P1L12DS3602).
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.