Description
1. Commercial Introduction
The absorbable monofilament suture of polyglecaprone 25 (PGCL / caprolactone) from the Prime range is the technical choice when the procedure requires controlled absorption, minimal inflammatory response and especially smooth thread passage through tissue. This presentation, factory reference P318HR2620VB (SKU AMP318HR2620VB), combines a ½ circle needle with cylindrical body and Taperpoint conical point VisiBlack of 26 mm, USP 2/0 gauge and 70 cm violet thread: a very versatile and cost-effective configuration for soft tissue approximation and ligatures in general surgery, gynaecology and obstetrics.
It is a medium-absorption thread (90–120 days), with exceptional handling and high knot security, designed for the professional who needs reliable wound support during the first weeks, with a very competitive cost-performance ratio for hospital procurement and purchasing groups. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.
2. Technical Explanation
Polyglecaprone 25 is a synthetic absorbable copolymer (glycolide and ε-caprolactone) with a monofilament structure that degrades by hydrolysis, i.e., by scission of the polymer chains upon contact with organic fluids, over a predictable period of 90 to 120 days independent of the patient’s enzymatic activity. Being a non-channeled monofilament, the strand presents a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, maintaining high tensile strength and reliable knot tying during the critical phases of wound healing.
The ½ circle needle with cylindrical body and Taperpoint conical point traverses soft tissues by separating the fibres without cutting effect, which makes it especially atraumatic in delicate structures, subcutaneous tissue and soft tissue approximation. The VisiBlack finish of the needle (darkened for maximum contrast) and the violet colour of the thread guarantee optimal visibility over the surgical field, even in environments with difficult lighting or bleeding. The USP 2/0 gauge (metric 3) provides an excellent balance between handling and initial strength. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AMP318HR2620VB
| Characteristic | Specification |
|---|---|
| Reference (SKU Cahnos) | AMP318HR2620VB |
| Factory reference | P318HR2620VB (PREMISUT POLYGLECAPRONE 25 CAPROLACTONE PGCL PRIME) |
| Range / Quality | Prime (premium range) |
| Material | Polyglecaprone 25 (PGCL / caprolactone), synthetic absorbable monofilament |
| Thread structure | Monofilament, non-channeled |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet (high visibility) |
| Needle shape | ½ circle (half circumference) |
| Needle body and point | Cylindrical body, Taperpoint conical point, VisiBlack finish |
| Needle size | 26 mm (HR 26) |
| Thread length | 70 cm (1 thread · 1 needle per unit) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 90–120 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, general surgery, gynaecology and obstetrics |
| Presentation | Box of 12 sterile units |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 1 week | 60 % |
| 2 weeks | 30 % |
| Complete absorption | 90–120 days by hydrolysis |
Complete absorption by hydrolysis between 90 and 120 days, with minimal tissue reaction, excellent initial tensile strength, optimal knot tying and a totally predictable absorption rate. Price per box of 12 units.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate diameter |
|---|---|---|
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 3/0 | 2 | 0.25 – 0.299 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
Polyglecaprone 25 monofilament is one of the most established families of medium-absorption synthetic absorbable sutures on the market, with the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech) being the clinical reference of the category. For the USP 2/0 configuration, ½ circle conical point needle and 70 cm violet strand, the following catalogue correspondences have been verified against manufacturer and authorised distribution sources, with the caveat that the commercial assembly of each house presents differences in needle geometry, composition or presentation, therefore they are not 1:1 interchangeable:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® Plus Antibacterial – polyglecaprone 25 monofilament with triclosan, violet, USP 2/0, 70 cm, cylindrical needle MH-1 31 mm, ½ circle, conical point | MCP247H | Comparable by category (not interchangeable 1:1) | They match material (polyglecaprone 25), USP 2/0 gauge, violet colour and thread length (70 cm); they differ in needle size (31 mm vs. 26 mm of HR26) and the antibacterial triclosan coating (relevant functional difference). Verify needle and centre preference before substituting in a tender. |
| B. Braun (Aesculap) | Monosyn – absorbable monofilament of glyconate, violet, USP 2/0, needle HRC26 26 mm, ½ circle, cylindrical body | C2022306 | Comparable by category (not interchangeable 1:1) | Confirmed in B. Braun official catalogue: matches USP 2/0 gauge, violet colour and needle size (26 mm); differ in polymer composition (glyconate: glycolide, caprolactone and trimethylene carbonate, not polyglecaprone 25), thread length and point finish. Validate reference by reference. |
There is no manufacturer-validated equivalence table for an exact 1:1 match with a Taperpoint VisiBlack HR26 26 mm conical needle, USP 2/0 gauge and 70 cm violet thread; consult the technical department before using in a tender. As homologous market families to verify in their official datasheet before a substitution, the MONOCRYL® / MONOCRYL® Plus line from Ethicon (polyglecaprone 25), Monosyn from B. Braun (glyconate), Biosyn and Caprosyn from Medtronic (glycomer) and medium-absorption monofilaments from other suppliers (SMI, Assut, DemeTECH) are cited, checking one by one: exact material, USP 2/0 gauge, ½ circle curvature, 26 mm needle size, conical point family, 70 cm thread length, violet colour and regulatory classification.
5. Selection tips and variants of interest
The USP 2/0 gauge offers an optimal balance between strength and fineness: it is indicated for subcutaneous tissue, superficial fascia, approximation of soft tissues and ligation of fine-to-medium calibre vessels. The 26 mm half-circle needle with a tapered point is the most atraumatic option for delicate tissues and confined spaces; if you require greater penetration in firm or slightly fibrous tissues, consider the trocar point (Tapercut) versions of the same family, and if you prefer a needle with a larger radius, the HR30 or HR48 versions from the catalogue.
| Reference | Recommended variant |
|---|---|
| AMP318HR2620VB | PGCL Prime, HR 26 mm needle, tapered point VisiBlack, USP 2/0, violet, 70 cm (product analysed) |
| AMP318HRP3020 | PGCL Prime, HRP 30 mm needle, tapered point Ultra Plus, USP 2/0, violet, 70 cm (larger radius, premium sharpness) |
| AMP318HRT2620 | PGCL Prime, HRT 26 mm needle, trocar point Tapercut, USP 2/0, violet, 70 cm (greater penetration in firm tissues) |
| AM318HRT2620 | PGCL Normal quality, HRT 26 mm needle, trocar point Tapercut, USP 2/0, violet, 70 cm (economical alternative, same needle) |
| AMP313HRP2620 | PGCL Prime, HRP 26 mm needle, tapered point Ultra Plus, USP 2/0, violet, 90 cm (same needle, longer thread) |
| AMP313HR4820 | PGCL Prime, HR 48 mm needle, tapered point, USP 2/0, violet, 90 cm (deep planes and wide fields) |
All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or validation of equivalences with other commercial houses, contact our technical-commercial team.





Reviews