Description
1. Commercial Introduction
PREMISUT RAPID is the accelerated absorption line from Cahnos for the professional who needs a resorbable thread with predictable handling, secure knotting and complete disappearance from the body within a few weeks, without the need to remove stitches. This configuration combines a braided multifilament strand of polyglycolic acid (PGAR), colourless and 75 cm, with a ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17 profile): the ideal choice for approximation of soft tissues, ligatures and general surgery, with excellent value for money for hospital replenishment, purchasing centres and B2B tenders.
2. Technical Explanation
The PGAR suture (rapid-profile, low molecular weight polyglycolic acid) is a synthetic polymer 100% absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread sliding and facilitates firm, secure knotting, with minimal tissue reaction and excellent initial tensile strength.
Its degradation profile is designed for short-duration healing: it retains 50% of tensile strength at 5 days and loses practically all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days. The HR17 needle features a ½ circle (160°) curvature with cylindrical body and Taperpoint conical point: the round body passes through soft tissues atraumatically and the conical point penetrates without aggressive cutting effect, avoiding enlargement of the exit hole. Its 17 mm length makes it especially suitable for reduced surgical fields, paediatric surgery, skin, subcutaneous tissue and mucous membranes. Product sterile by gamma radiation, single-use and non-reesterilizable.
3. Technical Specifications
3.1. Technical data sheet for the reference (Ref. 222HR1730 · SKU AM222HR1730)
| Parameter | Specification |
| Factory reference | 222HR1730 (official nomenclature PREMISUT RAPID) |
| Reference Cahnos (SKU) | AM222HR1730 |
| Brand / quality | PREMISUT RAPID (standard range) |
| Thread material | 100% polyglycolic acid (PGAR), synthetic absorbable, low molecular weight variant (RAPID) |
| Thread structure | Coated braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 3/0 (metric 2 / EP 2), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Colourless (undyed) |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Tip type | Taperpoint conical (atraumatic) |
| Needle size | HR 17 (17 mm), 1 needle per suture |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 40 and 45 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets, batch traceability) |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Absorption profile and tensile strength retention
| Post-implantation time | Retained tensile strength |
| 5 days | 50% of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglycolic acid (PGA line, 60–90 days) nor with standard polyglactin 910 (56–72 days).
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 5/0 | 1 | 0.10 – 0.149 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without extending its limits.
4. Equivalences and Cross-References
Rapid absorption polyglycolic acid (PGAR) belongs to the worldwide family of short-duration braided multifilament absorbable sutures, whose international clinical reference is the VICRYL RAPIDE line (polyglactin 910), with which it shares the hydrolysis absorption mechanism and accelerated resistance loss profile. Only the reference whose code and attributes have been verified against the manufacturer’s official catalogue and authorised distribution is included:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | VRI 215 H – USP 3/0, ½ circle cylindrical needle (SH) of 17 mm, colourless thread of 75 cm | Comparable by category (not interchangeable 1:1) | They match USP 3/0 gauge, colourless thread of 75 cm, ½ circle curvature and cylindrical needle of 17 mm with conical point; they differ in the polymer (polyglactin 910 versus polyglycolic acid) and the coating. Code verified in authorised distribution catalogue; check IFU before substituting. |
The remaining homologous lines of the rapid absorption segment (Safil Quick and Novosyn Quick from B. Braun / Aesculap, DemeCRYL Fast from DemeTECH and Surgicryl Fast Absorb from SMI) must be reviewed property by property —material, USP 3/0 gauge, multifilament structure, ½ circle curvature, conical point family, needle length 17 mm, 75 cm strand, colourless colour, 1 needle configuration and CE/MDR regulatory classification— before any substitution; no unverified cross-reference codes are published. Standard VICRYL (56–72 days absorption) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department of Cahnos before using in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are interchangeable with complete safety among themselves, respecting gauge and needle geometry.
5. Selection tips and variants of interest
The USP 3/0 (metric 2) gauge is a fine-medium size indicated for fast-healing tissues: skin approximation, subcutaneous tissue, mucous membranes, episiotomies, circumcisions and paediatric surgery. The HR17 ½-circle needle with Taperpoint conical tip combines the sharp entry of the tip with the non-traumatic passage of the cylindrical body: it is the recommended option for confined fields and soft tissues where an atraumatic passage is sought, without a broad cutting effect and with minimal bleeding. The colourless colour offers maximum discretion in the surgical bed.
| Variant (SKU) | Description |
| AMP222HR1730 (P222HR1730) | PGAR RAPID Prime – HR17 taperpoint – USP 3/0 colourless – 75 cm (same configuration, Prime quality; direct equivalent within the same manufacturer) |
| AMP222HR1740 (P222HR1740) | PGAR RAPID Prime – HR17 taperpoint – USP 4/0 colourless – 75 cm (same needle geometry, smaller gauge) |
| AMP222HR1750 (P222HR1750) | PGAR RAPID Prime – HR17 taperpoint – USP 5/0 colourless – 75 cm (fine gauge for very delicate tissues) |
| AM222HR2230 (222HR2230) | PGAR RAPID – HR22 taperpoint – USP 3/0 colourless – 75 cm (larger needle for wider fields) |
| AM222HR2630 (222HR2630) | PGAR RAPID – HR26 taperpoint – USP 3/0 colourless – 75 cm (26 mm needle, slightly larger field) |
| AM222HS1730 (222HS1730) | PGAR RAPID – HS17 reverse cutting (½ circle) – USP 3/0 colourless – 75 cm (triangular point for more fibrous tissues) |
Sterility and storage: product sterile by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each procedure and keep the reference 222HR1730 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions, hospital supply agreements or equivalents from other manufacturers, contact the technical-commercial team at Cahnos.