Description
1. Commercial Introduction
The absorbable multifilament suture PREMISUT RAPID Prime from the PGAR range (rapid-profile polyglycolic acid) is the accelerated absorption closure solution for the professional who needs a braided thread with predictable handling, secure knotting and complete disappearance from the body within a few weeks, without the need to remove stitches. This configuration combines a strand of 100 % polyglycolic acid in USP 2/0 gauge, colourless and 75 cm long, with a ½ circle needle with cylindrical body and Taperpoint conical point of 26 mm: atraumatic passage and minimal tissue damage, ideal for approximation of soft tissues, ligatures and general surgery.
Sterile product, ready to use, presented in a box of 12 units in individual sachets with batch traceability. Aimed at hospital replenishment, purchasing centres, clinics and tenders seeking a rapid absorption thread with an excellent price-quality ratio.
2. Technical Explanation
The PGAR suture (rapid-profile polyglycolic acid) is a synthetic polymer 100 % absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves sliding and facilitates firm, secure knotting, with minimal tissue reaction and excellent initial tensile strength.
Its degradation profile is designed for short-duration healing: it retains 50 % of tensile strength at 5 days and loses virtually all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days. The HR26 needle has a ½ circle curvature (1/2, 160°) with cylindrical body and Taperpoint conical point: the round body allows clean passage through soft tissues and the conical point separates fibres without aggressive cutting effect, minimising trauma to the puncture bed. The USP 2/0 gauge (metric 3) provides an optimal balance between strength and fineness for planes of moderate tension. Sterile product by gamma radiation, single-use and non-resterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. P222HR2620 · SKU AMP222HR2620)
| Parameter | Specification |
|---|---|
| Factory reference | P222HR2620 (nomenclature PREMISUT RAPID Prime) |
| Reference Cahnos (SKU) | AMP222HR2620 |
| Brand / quality | PREMISUT RAPID (Prime range) |
| Thread material | 100 % polyglycolic acid (PGAR), braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 2/0 (metric 3 / EP 3), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Colourless |
| Needle shape | ½ circle (1/2, 160°), cylindrical body |
| Needle tip | Conical / Taperpoint |
| Needle size | HR 26 (26 mm), 1 needle per suture |
| Swaged | 1 needle / 1 suture per unit |
| Absorption | By hydrolysis, completed between 40 and 45 days |
| Sterilisation | Gamma radiation; sterile, single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Absorption profile and tensile strength retention
| Post-implantation time | Retained tensile strength |
|---|---|
| 5 days | 50% of initial strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40 – 45 days, by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglycolic acid (60–90 days) or standard polyglactin 910 (56–72 days), also available in our catalogue.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 1 | 4 | 0.40 – 0.499 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
The strand diameter complies with the official ranges of the USP Pharmacopoeia for synthetic absorbable sutures, without extending its limits.
3.4. Decoding of the official reference
The official reference P222HR2620 decodes as: P (Prime quality) + 222 (75 cm thread) + HR26 (½ circle needle with cylindrical body and Taperpoint conical point of 26 mm) + 20 (USP 2/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
The reference P222HR2620 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid absorption polyglycolic acid, multifilament, USP 2/0, colourless 75 cm thread, ½ circle cylindrical needle with Taperpoint conical point of 26 mm, Prime quality). Rapid absorption polyglycolic acid (PGAR) is one of the most widespread short-duration braided absorbable suture families on the market and is comparable at a clinical category level with the rapid lines of major manufacturers. The following reference has been verified against the manufacturer’s official catalogue and authorised distribution:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (braided polyglactin 910, colourless) | W9975 – USP 2/0, 75 cm, undyed, ½ circle conical tip needle 31 mm | Comparable by category (not interchangeable 1:1) | They match on rapid absorption profile (≈42 days), USP 2/0 gauge, ½ circle curvature, conical point family, colourless colour, thread length 75 cm, braided structure and assembly of 1 needle. They differ in the base polymer (polyglactin 910 versus polyglycolic acid) and the needle size (31 mm versus HR26 of 26 mm). Code confirmed in the official Ethicon EMEA catalogue and authorised distribution. |
The rest of the homologous lines in the rapid absorption segment —Safil Quick and Novosyn Quick from B. Braun, DemeCRYL Fast from DemeTECH and Surgicryl Fast Absorb from SMI— must be reviewed property by property —material, USP 2/0 gauge, multifilament structure, ½ circle curvature, conical point family, needle length 26 mm, strand length 75 cm, colourless colour, 1 needle assembly and CE/MDR regulatory classification— before any substitution; they are not included in the table because no verified code is available for this exact combination. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other provided the gauge and needle geometry are respected.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) is a medium size indicated for approximation of tissues with moderate tension: skin, subcutaneous tissue, mucosa, ligatures, closure of planes and general surgery. The HR26 ½ circle needle with Taperpoint conical point passes through soft tissues separating the fibres without cutting effect: it is the recommended option for lax and well-perfused tissues, where an atraumatic passage and minimal bleeding are sought. If the tissue is denser, consider the same family with Tapercut trocar point (HRT26). The colourless colour offers maximum discretion in the field and is preferred in aesthetic areas or superficial tissue.
| Variant (SKU) | Description |
|---|---|
| AM222HR2620 (222HR2620) | PGAR RAPID – HR26 conical point – USP 2/0 colourless – 75 cm (same configuration, standard range) |
| AMP222HR2610 (P222HR2610) | PGAR RAPID Prime – HR26 taper point – USP 0 undyed – 75 cm (larger gauge, same needle) |
| AMP222HR2630 (P222HR2630) | PGAR RAPID Prime – HR26 taper point – USP 3/0 undyed – 75 cm (smaller gauge, same needle) |
| AMP222HR3020 (P222HR3020) | PGAR RAPID Prime – HR30 taper point – USP 2/0 undyed – 75 cm (30 mm needle, slightly larger field) |
| AMP222HR3620 (P222HR3620) | PGAR RAPID Prime – HR36 taper point – USP 2/0 undyed – 75 cm (36 mm needle for deeper layers) |
| AMP222HRT2620 (P222HRT2620) | PGAR RAPID Prime – HRT26 trocar point – USP 2/0 undyed – 75 cm (trocar point for firmer tissues) |
| AMP2L22HR2620 (P2L22HR2620) | PGLAR Polyglactin 910 RAPID Prime – HR26 taper point – USP 2/0 undyed – 75 cm (same geometry, glycolide/L-lactide copolymer) |
Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep the reference P222HR2620 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.