Description
1. Commercial Introduction
The multifilament absorbable suture PREMISUT RAPID from the PGAR range (rapid-profile polyglycolic acid) is the accelerated absorption closure solution for the professional who needs a resorbable thread with predictable handling, secure knotting and complete disappearance from the body within a few weeks, without the need to remove stitches. This configuration combines a braided strand of 100 % polyglycolic acid in USP 0 calibre, colourless and 90 cm long, with a ½ circle needle with cylindrical body and Taperpoint conical point of 36 mm (HR36 profile): atraumatic passage and minimal tissue damage, ideal for approximation of soft tissues, ligatures and general surgery. Sterile and ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability. Aimed at hospital replenishment, purchasing centres, clinics and B2B tenders seeking a rapid absorption thread with excellent value for money.
2. Technical Explanation
The PGAR suture (rapid-profile polyglycolic acid) is a synthetic polymer 100 % absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread sliding and facilitates firm, secure knotting, with minimal tissue reaction and excellent initial tensile strength. Its degradation profile is designed for short-term healing: it retains 50 % of tensile strength at 5 days and loses virtually all its resistance by 14 days, completing absorption by hydrolysis between 40 and 45 days.
The HR36 needle features a ½ circle curvature (160°) with a cylindrical body and Taperpoint conical point: the round body allows clean passage through soft tissues and the conical point separates fibres without aggressive cutting effect, minimising trauma to the puncture bed. Its 36 mm length makes it suitable for medium-depth planes, subcutaneous tissue, mucosa and approximation of tissues under moderate tension. The USP 0 calibre (metric 3.5) provides strength for medium-high tension planes. Sterilisation by gamma radiation; single-use product, not re-sterilisable. Contraindicated when prolonged tissue approximation is required, in cardiovascular and neurological tissues, and in patients allergic to its components.
3. Technical Specifications
3.1. General characteristics (Ref. 223HR3610 · SKU AM223HR3610)
| Parameter | Specification |
| Factory reference | 223HR3610 (nomenclature PREMISUT RAPID) |
| Reference Cahnos (SKU) | AM223HR3610 (box of 12 units) |
| Brand / quality | PREMISUT RAPID (standard range) |
| Thread material | 100 % polyglycolic acid (PGAR), braided multifilament, low molecular weight variant (RAPID) |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 0 (metric 3.5 / EP 3.5), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.35 – 0.399 mm |
| Thread length | 90 cm (free end, without loop) |
| Thread colour | Colourless (undyed) |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Needle tip | Conical / Taperpoint (atraumatic) |
| Needle size | HR36 (36 mm), 1 needle per suture |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 40 and 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets); minimum order of 30 boxes |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Absorption profile and tensile strength retention
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglycolic acid (PGA line, 60–90 days) or standard polyglactin 910 (56–72 days), also available in our catalogue.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 1 | 4 | 0.40 – 0.499 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
The strand diameter complies with the official USP Pharmacopeia ranges for synthetic absorbable sutures, without exceeding its limits.
3.4. Decoding of the official reference
The official reference 223HR3610 is decoded as: 223 (90 cm thread) + HR36 (½ circle needle with cylindrical body and Taperpoint conical point of 36 mm) + 10 (USP 0 calibre). Cahnos markets the official reference without altering characters: no digit should be added, removed or rearranged when ordering or bidding.
4. Equivalences and Cross-References
Reference 223HR3610 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid absorption polyglycolic acid, multifilament, USP 0, colourless 90 cm thread, ½ circle cylindrical needle with Taperpoint conical point of 36 mm). Rapid absorption polyglycolic acid (PGAR) is one of the most widespread short-term braided absorbable suture families on the market and is comparable at a clinical category level with the rapid lines of major manufacturers. The following reference has been verified against the manufacturer’s official catalogue and authorised distribution:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE™ (braided polyglactin 910, colourless) | V9460H – USP 0, CT-1 ½-circle conical-point 36 mm needle, undyed 90 cm suture | Comparable by category (not interchangeable 1:1) | They match in rapid absorption profile (≈42 days), braided multifilament, USP 0 calibre, ½ circle curvature, 36 mm needle with conical point (CT-1), colourless colour, 90 cm length and 1 needle configuration. They differ in the base polymer: polyglactin 910 (glycolide/L-lactide, Ethicon) versus low molecular weight polyglycolic acid (PGAR). Code confirmed in Ethicon’s official catalogue and authorised distribution. |
The remaining homologous lines in the rapid absorption segment —Safil Quick and Novosyn Quick from B. Braun / Aesculap, DemeCRYL Fast from DemeTECH and Surgicryl Fast Absorb from SMI— must be reviewed property by property (material, USP 0 calibre, multifilament structure, ½ circle curvature, conical point family, needle length 36 mm, thread length 90 cm, colourless colour, 1 needle configuration and CE/MDR regulatory classification) before any substitution; their codes for this exact configuration are pending confirmation with each manufacturer and are not published as closed data. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department of Cahnos before using in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other calibres, geometries and lengths (see block 5), which are fully interchangeable with each other respecting calibre and needle geometry.
5. Selection tips and variants of interest
USP 0 (metric 3.5) is a medium-high size indicated for planes with moderate tension: tissue approximation, ligatures, closure of deep planes, general surgery and minor surgery. The HR36 half-circle needle with Taperpoint conical point passes through soft tissues separating fibres without cutting effect: it is the recommended option for lax and well-perfused tissues, where an atraumatic passage and minimal bleeding are sought, with a wide radius suitable for medium-depth fields. If the tissue is denser, consider the same family with Tapercut trocar point (HRT series). The colourless colour offers maximum discretion in the field and is preferred in aesthetic or superficial tissue areas.
| Variant (SKU) | Description |
| AM223HR3610 (223HR3610) | PGAR RAPID – HR36 conical point – USP 0 colourless – 90 cm (this product, standard range) |
| AMP223HR3610 (P223HR3610) | PGAR RAPID Prime – HR36 conical point – USP 0 colourless – 90 cm (same geometry, Prime quality) |
| AM222HR3610 (222HR3610) | PGAR RAPID – HR36 conical point – USP 0 colourless – 75 cm (same needle and gauge, shorter strand) |
| AMP222HR3610 (P222HR3610) | PGAR RAPID Prime – HR36 conical point – USP 0 colourless – 75 cm (Prime quality, 75 cm strand) |
| AMP222HRT3620 (P222HRT3620) | PGAR RAPID Prime – HRT36 Tapercut trocar point – USP 2/0 undyed – 75 cm (trocar point for firmer tissues) |
| AMP2L22HR3610 (P2L22HR3610) | PGLAR Polyglactin 910 RAPID Prime – HR36 conical point – USP 0 colourless – 75 cm (glycolide/L-lactide copolymer, same geometry) |
Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep reference 223HR3610 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews