Description
1. Commercial Introduction
The Absorbable Multifilament Suture PGAR RAPID from the PREMISUT RAPID range is the accelerated-absorption closure solution for general surgery operating theatres, emergency departments, major ambulatory surgery and B2B purchasing centres that need a braided, flexible thread with early, predictable and fully documented loss of strength.
This reference combines a strand of 100 % polyglycolic acid in USP 0 calibre, undyed and 90 cm long, mounted with a ½ circle needle, cylindrical body and taperpoint conical point, 40 mm long (HR40 profile): the ideal choice for approximating tissues under medium tension, ligatures and general surgery procedures, with an excellent quality-price ratio for hospital replenishment, clinics and tenders. Presentation: box of 12 units with individual sterile sachets and batch traceability.
2. Technical Explanation
Rapid-absorption polyglycolic acid (PGAR) is a synthetic polymer 100 % absorbable by hydrolysis, spun in a braided multifilament structure and coated with polycaprolactone and calcium stearate, which reduces friction when passing through tissue, improves glide and facilitates firm, secure knotting with minimal tissue reaction.
In its rapid-absorption variant (RAPID, low molecular weight), degradation occurs by hydrolysis — a predictable process independent of the patient’s enzymatic activity — within 40 to 45 days, with retention of 50 % of the initial tensile strength at 5 days and total loss of tensile support at 14 days, therefore it is indicated when only short-term wound support is required.
The HR40 needle has a ½ circle curvature (160°) with a cylindrical body and taperpoint conical point: the round body passes through soft tissues atraumatically, while the sharp conical point allows entry with minimal resistance, being the geometry of choice for lax tissues, parenchyma, peritoneum, aponeurosis and deep planes in general surgery. Its 40 mm length makes it suitable for surgical fields of medium depth. Sterilisation by gamma radiation; single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. 223HR4010 · SKU AM223HR4010)
| Parameter | Specification |
|---|---|
| Factory reference | 223HR4010 (standard range) |
| Reference Cahnos (SKU) | AM223HR4010 |
| Brand / quality | PREMISUT RAPID (standard range) |
| Thread material | 100% polyglycolic acid (PGAR), synthetic absorbable, low molecular weight variant (RAPID) |
| Thread structure | Coated braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 0 (metric 3.5 / EP 3.5), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.35 – 0.399 mm |
| Thread colour | Colourless (undyed) |
| Thread length | 90 cm (free end, without loop) |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Needle tip | Taperpoint conical |
| Needle size | HR 40 mm (1 needle per strand) |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 40 and 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
|---|---|
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
The retention profile cited corresponds to the rapid-absorption formulation (RAPID line); it must not be confused with standard-absorption polyglycolic acid (PGA line, 60–90 days) nor with standard polyglactin 910 (56–72 days).
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2 | 5 | 0.50 – 0.599 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
The strand diameter complies with the official USP Pharmacopeia ranges for synthetic absorbable sutures, without extending their limits.
3.4. Decoding of the official reference
Official reference 223HR4010: 223 (90 cm thread) + HR40 (½ circle needle, cylindrical body, taperpoint conical point, 40 mm) + 10 (USP 0 calibre). Cahnos markets the official reference without altering characters: no digit should be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Reference 223HR4010 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid-absorption polyglycolic acid, multifilament, USP 0, undyed 90 cm thread, ½ circle cylindrical needle with 40 mm taperpoint conical point). Rapid-absorption polyglycolic acid (PGAR) belongs to the worldwide family of short-duration braided absorbable sutures of the PGA/polyglactin rapid-profile type, whose international clinical benchmark is the VICRYL RAPIDE line (Ethicon). The following reference has been cross-checked against sources from the manufacturer and authorised distribution; no reference should be considered interchangeable 1:1 without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | VICRYL RAPIDE (polyglactin 910, braided, undyed, rapid absorption) | VR9580 – USP 0, CT ½ circle needle with conical point, 40 mm, undyed 90 cm thread | Comparable by category (not interchangeable 1:1) | They match USP 0 calibre, undyed 90 cm thread, ½ circle curvature, conical-point family, 40 mm and rapid absorption profile (≈42 days); they differ in polymer (polyglactin 910: 90 % glycolide / 10 % L-lactide versus polyglycolic acid), coating and commercial needle nomenclature. Code verified in authorised distribution; check IFU before substituting. |
No equivalence table validated by the manufacturer exists; consult the technical department before use in tenders. Comparable ranges in the rapid-absorption segment include Safil Quick and NOVOSYN QUICK (B. Braun / Aesculap), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category for braided absorbable material, rapid absorption profile and early tensile strength retention; for the exact combination USP 0 / HR 40 mm taperpoint conical needle / 90 cm thread / 1-needle configuration, their specific codes must be confirmed with each manufacturer. Standard VICRYL (56–72 day absorption) is not equivalent to this RAPID version. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other calibres, geometries and lengths (see block 5), which are fully interchangeable with each other respecting calibre and needle geometry. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
USP 0 (metric 3.5) gauge offers an optimal balance between strength and handling, indicated for tissues under moderate tension: skin, subcutaneous tissue, mucosa, approximation of soft tissues and ligation of small and medium-calibre vessels. The HR40 half-circle needle with taperpoint conical point combines the sharp entry of the tip with the non-traumatic passage of the cylindrical body: it is the recommended option when seeking clean penetration in medium-consistency tissues without a broad cutting effect. The undyed version offers maximum discretion in the surgical bed; if greater visibility is required, consider the same configuration in dyed suture on request.
| Variant (SKU) | Description |
|---|---|
| AMP223HR4010 (P223HR4010) | PGAR RAPID Prime – HR40 taperpoint – USP 0 undyed – 90 cm (premium range, same geometry and gauge; direct equivalent within the same family) |
| AM223HR4001 (223HR4001) | PGAR RAPID standard – HR40 taperpoint – USP 1 undyed – 90 cm (same needle, larger gauge for more tension) |
| AM223HR4002 (223HR4002) | PGAR RAPID standard – HR40 taperpoint – USP 2 undyed – 90 cm (same needle, higher gauge for high tension) |
| AM223HR4810 (223HR4810) | PGAR RAPID standard – HR48 taperpoint – USP 0 undyed – 90 cm (same gauge, 48 mm needle for wider fields) |
| AM223HS4010 (223HS4010) | PGAR RAPID – HS40 reverse cutting – USP 0 undyed – 90 cm (cutting point for denser tissues) |
| AMP223HRT3610 (P223HRT3610) | PGAR RAPID Prime – HRT36 trocar point – USP 0 undyed – 90 cm (trocar point for firm tissues) |
| AM2L23HR4010 (2L23HR4010) | PGLAR RAPID (polyglactin 910) – HR40 taperpoint – USP 0 undyed – 90 cm (material alternative with rapid absorption) |
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight and below 30 °C, recording the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.