We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture Without Needle USP 1 Violet · 5 Threads of 70 cm · Polyglycolic Acid · Box of 12 units (Ref. 11-5.7001)

Original price was: 79,94 €.Current price is: 55,60 €.

Absorbable multifilament suture of 100% polyglycolic acid (PGA) without needle, USP size 1 (EP metric 4), supplied as 5 violet threads of 70 cm. Braided structure coated with polycaprolactone and calcium stearate for smooth passage, minimal tissue reaction and a firm, secure knot. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterile by ethylene oxide and single-use; indicated for tissue approximation, ligatures and general surgery. Presentation in a box of 12 units. Factory ref. 11-5.7001 · SKU Cahnos AM11-5.7001.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM11-5.7001

Description

1. About this suture

The absorbable multifilament PGA suture without needle in USP 1 gauge, presented in 5 strands of 70 cm in violet colour, is the reference solution for B2B supply of operating theatres, purchasing centres, general surgery clinics and healthcare distributors. As it does not have a mounted needle, the surgeon threads the strand onto the needle holder or ligature needle of their choice, providing maximum assembly flexibility and allowing them to make the most of their centre’s stock.

It is a synthetic absorbable, sterile and single-use medical device, with an excellent price-quality ratio for continuous supply. Factory reference 11-5.7001 · SKU Cahnos AM11-5.7001 · box of 12 units.

2. Technical explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer with a long clinical track record that is presented in a braided multifilament structure with a coating of polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces the saw effect, offers smooth handling and guarantees firm and secure knot tying, even in medium-high tension gauges such as USP 1.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating relevant tissue reaction. Complete absorption occurs between 60 and 90 days, maintaining the necessary tensile support during the critical healing phase: 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. It is especially valued for ligatures of medium and large calibre vessels, pedicles and approximation of planes with moderate tension in general surgery. The violet colour ensures optimal visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide (EtO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference 11-5.7001

Parameter Specification
Factory reference 11-5.7001
SKU Cahnos AM11-5.7001
Composition 100% polyglycolic acid (PGA), synthetic absorbable
Thread structure Braided multifilament with coating
Coating Polycaprolactone and calcium stearate
USP / metric gauge USP 1 (metric EP 4)
Approximate thread diameter 0.35 – 0.399 mm (according to USP/EP)
Thread colour Violet (colourless version available in the family)
Length / presentation 5 strands of 70 cm each, without needle
Absorption mechanism Hydrolysis, 60 – 90 days
Sterilisation Ethylene oxide (EtO); sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile sachets)
Regulatory standard USP / European Pharmacopoeia (EP)

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75% of the initial strength
3 weeks 50% of the initial strength
4 weeks 40% of the initial strength
Complete absorption 60 – 90 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
1 (this product) 4 0.35 – 0.399 mm
2 5 0.40 – 0.499 mm
0 3.5 0.30 – 0.339 mm
2/0 3 0.30 – 0.339 mm

The strand diameter meets the official ranges of the USP Pharmacopeia for synthetic absorbable sutures, without exceeding its limits.

4. Equivalences and Cross-References

Coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) is one of the most widely used absorbable suture families in general surgery, comparable at a clinical category level with the ligature lines without needle of major international manufacturers. The following homologous reference has been verified against the GUDID regulatory database (FDA):

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun Safil® Violet without needle (polyglycolic acid) B1038449 (catalogue number) / GUDID DI 04046963938666 Comparable by category (not interchangeable 1:1) Same principle: pure coated braided multifilament PGA, violet, without needle, presentation 5 x 70 cm, absorption by hydrolysis 60-90 days. They differ in the declared retention profile (approx. 60-70% at 14 days according to manufacturer) and coating details; verified against GUDID regulatory database with manufacturer data.

Furthermore, other homologous families of the same category present on the market are Surgicryl® PGA (SMI), Dexon / Dexon S (Medtronic), DemeSORB® PGA (DemeTECH) and AssuCryl® (Assut Medical); the specific codes for the needleless format in USP 1 gauge must be confirmed with each manufacturer before any substitution (the reference SMI 11200015 corresponds internally to another size/presentation of the same line, not to USP 1 5×70 cm). The VICRYL™ (Ethicon) and Novosyn® (B. Braun) ranges use a copolymer of polyglactin 910 (PGLA), chemically distinct from PGA homopolymer and with an absorption profile of 56-72 days, so they are not interchangeable 1:1 without technical validation. The brands cited belong to their respective manufacturers and are mentioned solely as a comparative reference; no unverified cross-reference codes are published.

There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender. To replace this reference in a specification, check one by one: exact material (PGA homopolymer), USP 1 gauge (EP 4), braided multifilament structure, needleless presentation, strand length per sachet (70 cm), number of strands, colour and CE/MDR regulatory classification.

5. Selection tips and variants of interest

The USP 1 gauge (metric EP 4) is the usual choice for ligatures of medium and large calibre vessels, pedicles, aponeurotic planes and approximation of tissues with moderate tension in general surgery. As it is a needleless presentation, it can be threaded with reusable ligature needles or freely combined according to the surgeon’s technique. The violet colour favours the visibility of the thread during the procedure, especially in bleeding fields; on demand, the range offers colourless thread for maximum aesthetic discretion.

Variant (SKU) Description
AM11-5.7001 (11-5.7001) PGA without needle – USP 1 violet – 5 × 70 cm (this product)
AM11-5.7002 (11-5.7002) PGA without needle – USP 2 violet – 5 × 70 cm (larger gauge, higher tension)
AM11-5.7010 (11-5.7010) PGA without needle – USP 0 violet – 5 × 70 cm
AM11-5.7020 (11-5.7020) PGA without needle – USP 2/0 violet – 5 × 70 cm (medium-low tension)
AM11-5.7030 (11-5.7030) PGA without needle – USP 3/0 violet – 5 × 70 cm (fine gauge)
AM11-10.6001 (11-10.6001) PGA without needle – USP 1 violet – 10 × 60 cm (greater number of strands per sachet)
AM11-12.4501 (11-12.4501) PGA without needle – USP 1 violet – 12 × 45 cm (high yield per sachet)
AM11-15001 (11-15001) PGA without needle – USP 1 violet – 150 cm (continuous ligature thread)

As it is a sterile single-use product, always check the integrity of the sachet and the expiry date before each procedure, keep the reference 11-5.7001 together with the lot number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight and below 30 °C. For special B2B conditions, hospital supply contracts or consultation of additional gauges, lengths and colours, contact the technical-commercial team at Cahnos.

Additional information

Material

100% polyglycolic acid (PGA), synthetic absorbable

Structure

Braided multifilament with coating

Coating

Polycaprolactone and calcium stearate

Gauge

USP 1 (metric EP 4)

Thread diameter

0.35 – 0.399 mm (according to USP/EP)

Thread colour

Violet (colourless available)

Armed length

5 strands of 70 cm, without needle

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EtO)

Use

Single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units (individual sterile sachets)

Manufacturer reference

11-5.7001

Regulatory standard

USP / European Pharmacopoeia (EP)

Medida de aguja

Needle-free

Usp

1

Color

Colourless, Violet

Medida de hilo

5 × 70 cm

Tipo de aguja

Without Needle

Forma de aguja

Without Needle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture Without Needle USP 1 Violet · 5 Threads of 70 cm · Polyglycolic Acid · Box of 12 units (Ref. 11-5.7001)”

Your email address will not be published. Required fields are marked *