Description
1. Commercial Introduction
At Cahnos we offer you the absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality from the PREMISUT range, reference P118GR4830 (SKU AMP118GR4830), a high-end professional solution for B2B supply to operating theatres, clinics and purchasing groups. This presentation combines a straight needle with cylindrical body and conical point of 48 mm (GR 48), USP 3/0 (metric 2) gauge and a 70 cm violet thread with high visibility on the surgical field.
It is the ideal choice for approximation of soft tissues, ligatures and general surgery, with predictable absorption by hydrolysis that avoids thread removal, reliable mechanical support during the first weeks of healing and special B2B ordering conditions for hospitals and volume buyers. It is supplied sterile, ready for immediate use in the operating theatre, in a box of 12 units.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer, structured as a braided multifilament with a coating of polycaprolactone and calcium stearate. This combination ensures smooth passage through tissue, low thread memory, non-ribbed surface and firm, secure knot seating, even in fine gauges such as USP 3/0 (metric 2).
Its absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable interval of 60 to 90 days. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing (75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks), while the tissue recovers its own resistance.
The straight needle with cylindrical body and conical point (Taperpoint geometry) of 48 mm passes through tissue separating the fibres without cutting effect: it is the most atraumatic configuration for soft and friable tissues, with precise penetration and minimal damage along the path, ideal for manual suturing on directly accessible surfaces. The violet colour ensures optimal visibility throughout the procedure. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference P118GR4830
| Characteristic | Specification |
| Reference (SKU) | AMP118GR4830 |
| Catalogue reference | P118GR4830 |
| Brand / Quality | Premisut – Prime |
| Material | 100 % synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament, non-grooved surface |
| Coating | Polycaprolactone and calcium stearate |
| USP / metric gauge | USP 3/0 (metric 2) |
| Thread length | 70 cm |
| Thread colour | Violet |
| Needle shape | Straight |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 48 mm (GR 48 Prime) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period | Tensile strength retention |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 3/0 | 2 | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Braided and coated multifilament polyglycolic acid (PGA) is one of the most established medium-absorption synthetic absorbables on the market (classic ‘Dexon’ type family). This Prime reference, with hydrolysis absorption of 60–90 days, tensile strength retention of 75/50/40 % at 2/3/4 weeks and a 48 mm Taperpoint conical-point straight needle, is comparable at category level (not 1:1 interchangeable) with the following homologous lines verified against official source:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| SMI (Belgium) | Surgicryl® PGA – round body Taperpoint conical point | 11300148 (USP 3/0, 1/2 circle needle HR 48 mm, 75 cm, violet, box of 12) | Comparable by category (not interchangeable 1:1) | Same 100 % PGA braided coated with polycaprolactone and calcium stearate, same USP 3/0 gauge, same violet colour and 60–90 day absorption; they differ in needle geometry (1/2 circle HR 48 vs straight GR 48) and thread length (75 cm vs 70 cm). Verified in official SMI catalogue (Rev. 10). |
| Ethicon (Johnson & Johnson) | Coated VICRYL® (polyglactin 910) – straight needle KS 60 mm | J663H (USP 3/0, 70 cm, undyed, straight reverse-cutting needle KS, box of 36) | Comparable by category (not interchangeable 1:1) | Different material (polyglactin 910 copolymer, not PGA) and undyed colour (not violet); straight reverse-cutting needle KS 60 mm vs straight conical-point GR 48 mm. Absorption 56–72 days and retention of 75 % at 2 weeks, 50 % at 3 and 25 % at 4. |
At category level, they are also homologous lines of braided coated PGA without a code verifiable in public sources for this exact straight needle GR 48 mm configuration: AssuCryl® (Assut Sutures), Petcryl (Dolphin Sutures), DemeSORB® PGA (DemeTECH) and the historical Dexon® / Dexon II® series (Medtronic). In the polyglactin 910 (PGLA) segment, a material from the same clinical family although of different composition, are Safil (B. Braun), Polysorb (Medtronic) and Vitacryl (DemeTECH). Within the Cahnos catalogue, the reference with the same needle geometry (straight GR 48 mm, USP 3/0, violet, 70 cm) in polyglactin 910 is P1L18GR4830 (absorption 56–72 days).
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (straight conical-point needle GR 48 mm, USP 3/0 gauge, violet, 70 cm) with exact codes from other commercial houses: the identified matches must be treated as functional category comparisons and not as 1:1 interchangeable without technical validation. Consult the technical-commercial department of Cahnos before using this information in tenders or in the direct substitution of references. The cited brands belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP 3/0 (metric 2) gauge is very versatile and is indicated for skin, subcutaneous tissue, mucosa, fascia and soft tissues with moderate tension in general surgery and ligatures. The 48 mm straight conical-point needle (GR 48) is especially suitable for manual suturing on directly accessible surfaces where atraumatic penetration in delicate tissues is prioritised.
| Reference | Variant of interest |
| P1L18GR4830 | PGLA Prime, same straight needle GR 48 mm, USP 3/0, violet, 70 cm (absorption 56–72 days) |
| AMP118GS4830 | PGA Prime, conventional cutting straight needle GS 48 mm, USP 3/0, undyed, 70 cm (for firm tissues) |
| AMP118GR1930 | PGA Prime, straight needle GR 19 mm, USP 3/0, violet, 70 cm (shorter needle) |
| AMP118HR4830 | PGA Prime, 1/2 circle needle HR 48 mm, USP 3/0, violet, 70 cm (curved needle) |
| AMP118GS2530 | PGA Prime, straight needle GS 25 mm, USP 3/0, violet, 70 cm (short conventional cutting) |
All references are supplied in boxes of 12 units with a minimum order of 30 boxes. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders and hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.