Description
1. Commercial Introduction
At Cahnos we make available to hospitals, private clinics, general and ophthalmic surgery operating theatres and purchasing centres the absorbable multifilament polyglycolic acid (PGA) suture from the PREMISUT Prime range, reference AMP118FR3610 (manufacturer ref. P118FR3610). It is a high-performance, manageable, safe synthetic absorbable surgical suture with a very competitive price-quality ratio for institutional procurement.
This presentation combines a ⅝ circle needle with cylindrical body and taper point of 36 mm (FR 36) with a violet grooved braided thread of USP 0 gauge and 70 cm length: a very versatile profile, suitable for approximation of soft tissues, ligatures and precision procedures in general and ophthalmic surgery. Each unit is supplied sterile, ready to use and single-use, in a box of 12 units with a minimum order of 30 boxes, ensuring continuity of supply for your healthcare centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a grooved finish. This configuration favours the sliding of the thread through tissue, provides smooth handling, low memory and firm, secure knot tying in medium gauges such as USP 0 (metric 3.5). The coating of polycaprolactone and calcium stearate improves passage through tissue and reduces tissue reactivity.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing (75% at 2 weeks, 50% at 3 and 40% at 4), while the tissue recovers its own resistance.
The ⅝ circle needle with cylindrical body and taper point of 36 mm penetrates by separating the fibres without cutting effect, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery, soft tissue approximation and ligatures. The grooved violet colour ensures optimal visibility of the thread on the surgical field. Product sterile by ethylene oxide (EO), single-use and not resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference AMP118FR3610
| Characteristic | Specification |
|---|---|
| Reference (SKU) | AMP118FR3610 (manufacturer ref. P118FR3610) |
| Range / Quality | PREMISUT – Prime |
| Material | 100% Polyglycolic Acid (PGA), absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| USP / metric gauge | USP 0 (metric 3.5) |
| Thread colour | Violet grooved |
| Thread length | 70 cm |
| Needle shape | ⅝ circle (5/8) |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | 36 mm (FR 36 Prime) |
| Absorption mechanism | Hydrolysis (60-90 days) |
| Sterilisation | Ethylene oxide (EO); sterile, single-use |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Approximation of soft tissues, ligatures, general and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60-90 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
3.4. Presentation and ordering conditions
| Value | Value |
|---|---|
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
Pure polyglycolic acid (PGA) is one of the most widely used braided synthetic absorbable materials on the market. Reference AMP118FR3610 is comparable by category, composition, absorption profile and tensile retention, with the coated multifilament sutures of the main manufacturers. The verified cross-references in the GUDID (FDA) regulatory database with the same FR 36 needle pattern are indicated below:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | Safil Violet | C1048426 (SAFIL VIOLET 0 (3.5) 70CM FR36 (M)) | Comparable by category (not interchangeable 1:1) | Same 100% braided coated polyglycolic acid homopolymer, violet colour, FR 36 needle (5/8 circle, cylindrical body, taper point, designation Easyslide) and 70 cm thread; absorption by hydrolysis 60-90 days. Code verified in GUDID (B Braun Surgical SA). Confirm with the manufacturer the commercial availability of the assembly on the European market before any substitution. |
| B. Braun | Novosyn Violet | C0068426 (NOVOSYN VIOLET 0 (3.5) 70CM FR36 (M) DDP) | Comparable by category (not interchangeable 1:1) | Polyglactin 910 (PGLA 90/10) braided, violet, FR 36 needle and 70 cm thread. Polymer different from the 100% PGA of this data sheet, with a somewhat faster absorption profile (56-70 days). Code verified in GUDID and in the B. Braun catalogue. |
Furthermore, by composition and mechanical behaviour, this suture is comparable at category level with the 100% PGA braided lines from Medtronic/Covidien (Dexon II), DemeTECH (DemeSORB PGA), SMI (Surgicryl PGA), Dolphin Sutures (Petcryl) and CPT Sutures (CARESYN PGA), as well as with the polyglactin 910 lines from Ethicon (Vicryl), Medtronic (Polysorb), SMI (Surgicryl 910) and Assut (Assucryl 910). The reference codes of these other manufacturers for the exact FR 36 / 0 / 70 cm configuration could not be conclusively verified in public sources, so they are not declared here. There is no equivalence table validated by the manufacturer for this cross-reference; consult the technical department before use in tendering.
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) offers an excellent balance between initial strength and fineness: it is suitable for subcutaneous tissue, superficial muscular planes, mucosa, soft tissue approximation, ligatures and ophthalmic surgery procedures, with predictable absorption during a 2 to 4 week healing period. The ⅝ circle needle with taper point of 36 mm is the most atraumatic option for delicate tissues and deep, reduced access fields; if greater penetration into firm tissues (sclera, dense fasciae) is required, consider trocar, blunt or reverse cutting points within the same range. Verify the needle radius (FR 27, FR 36 or FR 40 mm) according to the depth and surgical area to be treated; for greater tensile strength consider USP 1 or higher gauges, and if a longer strength retention is required (180-210 days), the polydioxanone (PDO) family is the recommended alternative.
| Reference | Variant |
|---|---|
| AMP118FR3610 | PGA Prime USP 0, FR 36 mm needle (5/8 circle), violet, 70 cm (current product) |
| AM118FR3610 | PGA USP 0, FR 36 mm needle, violet, 70 cm (standard range of the same family) |
| AMP118FR3620 | PGA Prime USP 2/0, FR 36 mm needle, violet, 70 cm (fine gauge) |
| AMP118FR3601 | PGA Prime USP 1, FR 36 mm needle, violet, 70 cm (higher initial strength) |
| AMP118FR4020 | PGA Prime USP 2/0, FR 40 mm needle, violet, 70 cm (larger needle radius) |
| AMP118HR3610 | PGA Prime USP 0, ½ circle HR 36 mm needle, violet, 70 cm (most universal curve) |
| P1L18FR3610 | PGLA Prime USP 0, FR 36 mm needle, violet, 70 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units with a minimum order of 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other commercial houses, contact our technical-commercial team.





Reviews