We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Prime PGA Multifilament Absorbable Suture – ⅜ Circle Needle Precision Reverse Cutting Triangular Point XDS 19 mm Square Body – USP 4/0 – Undyed – 45 cm – Box of 12 units (Ref. P121XDS1940)

Original price was: 63,18 €.Current price is: 41,30 €.

Prime PGA multifilament absorbable suture (100 % polyglycolic acid) with a ⅜ circle needle with precision reverse cutting triangular point and 19 mm square body (XDS-19 profile), ideal for clean and controlled penetration into firm tissues with optimal cosmetic outcome. USP 4/0 gauge (metric 1.5), undyed non-grooved 45 cm thread, coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 40 % at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Presentation in box of 12 units · minimum order 30 boxes. Ref. P121XDS1940 · SKU AMP121XDS1940.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP121XDS1940

Description

1. Commercial Introduction

The absorbable multifilament PGA Prime suture (100% polyglycolic acid) is the reference choice for professionals seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery. Its ⅜ circle needle with precision reverse cutting triangular point and 19 mm square body (XDS-19 profile) ensures firm, controlled penetration in non-compliant tissues, while the 45 cm undyed braided thread offers a discreet final aesthetic and smooth glide during suturing.

It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for B2B supply to operating theatres, purchasing centres and distributors of surgical supplies. Commercial presentation in a box of 12 units, with special conditions for professional buyers and a minimum order of 30 boxes.

2. Technical explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a non-grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces the sawing effect, offers smooth handling and guarantees firm, secure knot tying, even in fine working calibres such as USP 4/0.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. The tensile strength retention profile maintains the necessary support during the critical phase of healing, while the tissue recovers its own strength.

The XDS-19 needle (⅜ circle, 19 mm) concentrates the cutting edge on the outer face of the curvature with a precision reverse cutting triangular point (Reverse Extra Cutting, extra-long cutting edge) and square body: it penetrates skin, dense subcutaneous tissue and aponeurosis with minimal trauma, prevents the cut from widening in the puncture bed and optimises the cosmetic result. The square body improves grip in the needle holder, preventing rotation and increasing the precision of the surgical gesture. The undyed colour reduces visual interference on the surgical field. Sterilisation by ethylene oxide (EtO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference P121XDS1940

Parameter Specification
Factory reference P121XDS1940
Reference Cahnos (SKU) AMP121XDS1940
Material 100 % absorbable polyglycolic acid (PGA)
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament, smooth finish
Gauge USP 4/0 (metric EP 1.5)
Approximate thread diameter 0.15 – 0.199 mm (indicative according to USP/EP)
Thread colour Undyed (not dyed); violet version on request
Thread length 45 cm (1 strand / 1 needle per unit)
Needle shape 3/8 circle (approx. 135°)
Tip type Precision reverse cutting triangular (Reverse Extra Cutting), extra-long cutting edge
Needle body Square (cosmetic / plastic configuration), non-grooved
Needle size XDS-19 (19 mm), 1 needle per suture
Absorption mechanism Hydrolysis, 60 – 90 days
Sterilisation Ethylene oxide (EtO); single-use, not resterilisable
Tissue reaction Minimal
Regulatory standard Conforms to USP and European Pharmacopoeia (EP) calibres; medical device with CE marking
Indications Tissue approximation, ligatures and general surgery; commonly used in plastic and cosmetic surgery
Presentation Box of 12 units · minimum order 30 boxes

3.2. Absorption profile and tensile strength retention

Time point Tensile strength retention
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Complete absorption 60 – 90 days by hydrolysis

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate diameter
5/0 1 0.10 – 0.149 mm
4/0 (this product) 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm

3.4. Reference code decoding

The official reference P121XDS1940 breaks down as follows: P (Prime range) + 121 (45 cm thread) + XDS19 (⅜ circle needle with precision reverse cutting triangular point and 19 mm square body, plastic / cosmetic profile) + 40 (USP 4/0 calibre). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or bidding.

4. Equivalences and Cross-References

Braided, coated multifilament polyglycolic acid (PGA) with medium absorption (60–90 days) is one of the most widely used synthetic absorbables in the surgical market. The configuration of this reference (pure PGA, USP 4/0 calibre, ⅜ circle 19 mm reverse cutting needle, 45 cm undyed thread) has been compared against the official catalogues of manufacturers and regulatory bases. As these are other manufacturers, equivalence is declared at category level, never interchangeable 1:1 without validation by the technical service, and differs mainly in needle geometry (no competitor offers the XDS profile with square body and extra-long cutting edge).

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Safil® Undyed — pure polyglycolic acid, coated braided multifilament C1049420 Comparable by category (not interchangeable 1:1) Safil undyed USP 4/0 (EP 1.5), 70 cm, DS19 needle (19 mm, ⅜ circle, reverse cutting). Material, calibre, needle and colour match; thread length differs (70 cm vs 45 cm), needle geometry (standard DS vs precision XDS with square body) and coating. Code verified in the official B. Braun catalogue.
SMI (Surgical Materials Industries) Surgicryl® PGA — polyglycolic acid, braided multifilament coated with polycaprolactone and calcium stearate 11151519U Comparable by category (not interchangeable 1:1) Surgicryl PGA USP 4/0 (1.5), undyed, DS 19 mm 3/8 circle reverse cutting needle, 75 cm thread. Material, coating, calibre, needle and colour match; thread length differs (75 cm vs 45 cm) and needle profile. Code verified in the official SMI catalogue.
DemeTECH DemeSORB® PGA — polyglycolic acid, braided coated PGA274019F4P (DFS-2, 19 mm) Comparable by category (not interchangeable 1:1) DemeSORB PGA USP 4/0, undyed, 3/8 circle reverse cutting DFS-2 needle of 19 mm, 75 cm thread. Material and calibre match; length, needle geometry (DFS-2 vs XDS19 with square body) and the retention profile published by the manufacturer differ. Configuration confirmed in the official DemeTECH store and authorised distributors.

As homologous families of the segment identified on the market, whose technical data sheets must be consulted before any substitution and for which no verified code is available in this specific configuration (4/0 · 45 cm · XDS19 with square body): Coated Vicryl® / Vicryl Rapide™ (Ethicon, polyglactin 910), Polysorb™ (Medtronic/Covidien), Safil® Quick (B. Braun) and the PGA ranges from Assut Medical. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.

There is no equivalence table validated by the manufacturer that declares this specific configuration (Prime multifilament PGA, ⅜ circle XDS-19 needle of 19 mm with precision reverse cutting triangular point and square body, USP 4/0 gauge, undyed 45 cm thread, ref. P121XDS1940) as interchangeable 1:1 with references from other manufacturers; consult the technical department of Cahnos before use in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (19 mm), ⅜ curvature, point family (precision reverse cutting), needle body (square), thread length (45 cm), colour and coating. Copolymer polyglactin 910 (PGLA) ranges, such as Vicryl® from Ethicon, are chemically different from homopolymer PGA and should not be treated as interchangeable 1:1 without validation.

5. Selection tips and variants of interest

USP 4/0 gauge (metric 1.5) is indicated for fine tissues and moderate tension: skin, subcutaneous tissue, mucous membranes, fascia and standard healing planes. The precision reverse cutting point with square body (XDS-19) penetrates firm tissues without tearing the puncture bed, making it especially suitable for plastic, cosmetic and dermatological surgery: better aesthetic outcome and less trauma. The undyed, non-grooved thread is chosen when maximum discretion in the field is required; if visibility over the surgical field is preferred, consider the violet version of the same family on request.

Variants within the same Prime XDS family (precision reverse cutting with square body, undyed, 45 cm) available at Cahnos:

Reference Variant of interest
AMP121XDS1940 PGA Prime, XDS 19 mm needle, USP 4/0, undyed, 45 cm (product analysed)
AMP121XDS1930 PGA Prime, XDS 19 mm needle, USP 3/0, undyed, 45 cm (larger gauge)
AMP121XDS1950 PGA Prime, XDS 19 mm needle, USP 5/0, undyed, 45 cm (finer gauge)
AMP121XDS1340 PGA Prime, XDS 13 mm needle, USP 4/0, undyed, 45 cm (shorter needle)
P1L21XDS1940 PGLA Polyglactin 910 Prime, same XDS 19 mm needle, USP 4/0, undyed, 45 cm (absorption 56–72 days)
AMP221XDS1940FN PGAR Rapid Prime, same XDS 19 mm needle, USP 4/0, undyed, 45 cm (absorption 40–45 days)
AMP321XDS1940 PGCL Caprolactone 25 monofilament Prime, same XDS 19 mm needle, USP 4/0, undyed, 45 cm (absorption 90–120 days)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to the healthcare facility. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight and below 30 °C. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.

Additional information

Material

100% Polyglycolic Acid (PGA)

Thread structure

Braided multifilament, smooth finish

Coating

Polycaprolactone and calcium stearate

Gauge

USP 4/0 (metric 1.5)

Thread diameter

0.15 – 0.199 mm (USP/EP)

Needle shape

3/8 circle (approx. 135°)

Tip type

Precision reverse cutting triangular (Reverse Extra Cutting)

Needle body

Square (cosmetic / plastic configuration)

Needle size

XDS-19 (19 mm), 1 needle per suture

Absorption mechanism

Hydrolysis, 60 – 90 days

Strength retention

75% (2 weeks), 50% (3 weeks), 40% (4 weeks)

Sterilisation

Ethylene oxide (EtO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery; plastic and cosmetic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P121XDS1940

Regulatory standard

USP/EP · CE marking

Medida de aguja

XDS 19

Usp

4/0

Color

Colourless

Medida de hilo

45 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Prime PGA Multifilament Absorbable Suture – ⅜ Circle Needle Precision Reverse Cutting Triangular Point XDS 19 mm Square Body – USP 4/0 – Undyed – 45 cm – Box of 12 units (Ref. P121XDS1940)”

Your email address will not be published. Required fields are marked *