We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Multifilament Absorbable PGA Suture (Polyglycolic Acid) | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm) | USP 4/0 | Violet Fluted 75 cm | Ref. 112DS1940 | Box of 12 units

Original price was: 34,90 €.Current price is: 26,90 €.

Multifilament absorbable suture of polyglycolic acid (PGA) from the PREMISUT range (ref. 112DS1940), mounted on a ⅜ circle needle with reverse cutting triangular point of 19 mm (DS19). USP gauge 4/0 (metric 1.5), violet fluted thread of 75 cm coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, single-use, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Box of 12 units. SKU AM112DS1940.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM112DS1940

Description

1. Commercial Introduction

The multifilament absorbable suture of polyglycolic acid (PGA) PREMISUT is the reference solution for operating theatre services, purchasing centres and distributors looking for a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery.

This presentation incorporates a ⅜ circle needle with a 19 mm reverse cutting triangular point (DS19), USP 4/0 gauge (metric 1.5) and a 75 cm violet fluted thread. Sterile medical device, single-use, ready to use, in a box of 12 units. Tariff reference 112DS1940 · SKU Cahnos AM112DS1940.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer widely used in surgical sutures, presented here in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces the sawing effect, offers smooth sliding and guarantees excellent knot security, even in fine gauges such as USP 4/0.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, which the body metabolises without generating significant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical phase of healing while the tissue recovers its own resistance.

The ⅜ circle needle with a 19 mm reverse cutting triangular point (inverted triangular / reverse cutting) penetrates firm, fibrous and non-compliant tissues (skin, fascia, aponeurosis) with controlled trauma and without tearing the planes, being especially suitable for skin closures, soft tissue approximation, ligatures and reduced surgical fields. The violet colour improves the visibility of the thread on the surgical field. Sterilisation by ethylene oxide (EO); does not allow re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference 112DS1940

Parameter Specification
Brand / Range PREMISUT (standard quality)
Catalogue reference 112DS1940
SKU Cahnos AM112DS1940
Composition 100 % Polyglycolic Acid (PGA), absorbable by hydrolysis
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 4/0 (metric 1.5)
Thread colour Violet (also available undyed in the range)
Thread length 75 cm
Needle shape 3/8 circle (approx. 135°)
Tip type Triangular with reverse cutting (inverted triangular / reverse cutting)
Needle size DS19 (19 mm)
Absorption mechanism Hydrolysis, between 60 and 90 days
Tensile strength retention 2 weeks 75 % · 3 weeks 50 % · 4 weeks 40 %
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units

3.2. Tensile strength retention profile after implantation

Period Tensile strength retention
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Complete absorption 60-90 days by hydrolysis

Excellent initial tensile strength, optimal knot tying and fully predictable absorption rate, with minimal tissue reaction.

3.3. Size equivalence

USP size Metric size Approximate diameter (USP/EP, indicative)
4/0 1.5 0.15 – 0.199 mm

4. Equivalences and Cross-References

The coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) corresponds to the homologous families of the main manufacturers on the market: pure PGA is the material of the Safil (B. Braun), Surgicryl (SMI) and DemeSORB (DemeTECH) lines; the Vicryl (Ethicon, polyglactin 910) and Polysorb (Medtronic, Lactomer) ranges are copolymers based on glycolide, comparable by clinical category but not interchangeable 1:1 with the PGA homopolymer. The references cited below have been verified in official catalogues or authorised stores of each manufacturer.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
SMI (Surgical Materials Industries, Belgium) Surgicryl® PGA (polyglycolic acid, braided multifilament coated with polycaprolactone and calcium stearate) 11151519 (violet) Comparable by category (not interchangeable 1:1) Surgicryl PGA USP 4/0 (metric 1.5) with a DS19 needle of ⅜ circle and 19 mm reverse cutting, 75 cm thread; matches in material (100% PGA), coating, gauge, needle, length and violet colour. Configuration confirmed in the official SMI catalogue and authorised distributors; verify needle geometry before substituting. Box of 12 units.
DemeTECH (USA) DemeSORB® PGA (polyglycolic acid, braided coated) PGA284019F4P (violet) Comparable by category (not interchangeable 1:1) DemeSORB PGA USP 4/0, 75 cm (30″) thread and 3/8 circle reverse cutting DFS-2 needle of 19 mm; matches in material (PGA coated with polycaprolactone and calcium stearate), gauge, length, colour and needle size. Configuration confirmed in the official DemeTECH store and authorised distributors; the published retention profile differs (84% at 2 weeks / 23% at 4 weeks) compared to the PREMISUT profile. Box of 12 units.
B. Braun (Aesculap) Safil® (pure polyglycolic acid, braided coated multifilament) C1048420 (violet) Comparable by category (not interchangeable 1:1) Safil 4/0 (metric 1.5) violet with a DS19 needle of ⅜ circle and 19 mm reverse cutting; the thread length differs (70 cm vs 75 cm) and the coating. Code confirmed in official B. Braun catalogues and authorised distributors; verify coating and presentation before substituting.

There is no equivalence table validated by the manufacturer for this specific configuration (multifilament PGA, ⅜ circle DS19 needle of 19 mm, reverse cutting triangular point, USP 4/0 gauge, 75 cm violet thread); consult the technical department of Cahnos before using in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (19 mm), ⅜ curvature, point family (reverse cutting), thread length (75 cm) and colour. The copolymer ranges of polyglactin 910 (PGLA), such as Vicryl (Ethicon), and Lactomer (Polysorb, Medtronic) are chemically different from the PGA homopolymer and are not interchangeable 1:1 without validation from the technical department. The brands cited belong to their respective manufacturers and are mentioned only as a reference for equivalence.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is ideal for skin, subcutaneous tissue, low-tension soft tissues and ligatures, offering an excellent balance between initial strength and handling. The 19 mm DS19 needle with reverse cutting triangular point is indicated when firm tissues need to be penetrated without tearing in reduced surgical fields. The violet colour favours the visibility of the thread during the procedure; if maximum aesthetic discretion is preferred, there is a colourless version of the same configuration.

Reference Variant
AM112DS1940 PGA USP 4/0, ⅜ triangular DS19 needle, violet, 75 cm (current product)
AM122DS1940 PGA USP 4/0, same DS19 needle, colourless fluted, 75 cm (colourless variant)
AMP112DS1940 PGA Prime quality USP 4/0, DS19 needle, violet, 75 cm (superior quality)
AM111DS1940 PGA USP 4/0, DS19 needle, violet, 45 cm (shorter thread)
AM112DS1930 PGA USP 3/0, same DS19 needle, violet, 75 cm (larger gauge)
AM112DS1950 PGA USP 5/0, same DS19 needle, violet, 75 cm (finer gauge)
AM112DS1640 PGA USP 4/0, DS16 needle, violet, 75 cm (shorter needle)
1L12DS1940 PGLA (polyglactin 910) USP 4/0, DS19 needle, violet, 75 cm (absorption 56-72 days)

All references are supplied in boxes of 12 units. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, store it in a cool, dry place, protected from sunlight, and respect the expiry date. For special B2B conditions, volume orders or enquiries about other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

100 % absorbable polyglycolic acid (PGA)

Coating

Polycaprolactone and calcium stearate

USP size

4/0 (metric 1.5)

Needle tip

Triangular reverse cutting (reverse cutting), body and point

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Presentation

Box of 12 units

Manufacturer reference

112DS1940

Intended use

Tissue approximation, ligatures and general surgery

Brand

PREMISUT

Thread structure

Braided multifilament with grooved finish

Gauge

USP 4/0 (metric 1.5)

Needle shape

3/8 circle (approx. 135°)

Tip type

Triangular with reverse cutting (inverted triangular / reverse cutting)

Needle size

DS19 (19 mm)

Medida de aguja

DS 19

Usp

4/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Multifilament Absorbable PGA Suture (Polyglycolic Acid) | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm) | USP 4/0 | Violet Fluted 75 cm | Ref. 112DS1940 | Box of 12 units”

Your email address will not be published. Required fields are marked *