We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture (Polyglycolic Acid) | ⅜ Circle Needle Reverse Cutting Triangular Point DS24 (24 mm) | USP Gauge 3/0 (Metric 2) | Colourless Braided Thread 75 cm | Ref. P122DS2430 | Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality from the PREMISUT range: ⅜ circle needle with reverse cutting triangular point (inverted triangle) of 24 mm (DS24), USP gauge 3/0 (metric 2) and colourless braided grooved thread of 75 cm, coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis between 60 and 90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide, single-use and not re-sterilisable: minimal tissue reaction and excellent knot security for tissue approximation, ligatures and general surgery. List reference P122DS2430 · Code Cahnos AMP122DS2430 · Presentation in boxes of 12 units with a minimum order of 30 boxes for B2B supply.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP122DS2430

Description

1. Product Presentation

The PGA Prime multifilament absorbable suture from the PREMISUT range is the reference solution for operating theatre services, purchasing centres and distributors looking for a synthetic absorbable thread with controlled absorption, excellent handling and fully predictable clinical behaviour. The Prime quality guarantees a regular surface and smooth sliding that minimises tissue damage during suturing.

This presentation incorporates a ⅜ circle needle with a triangular reverse cutting point (inverted triangle) of 24 mm (DS24), USP 3/0 (metric 2) gauge and a 75 cm colourless grooved thread, ideal for tissue approximation, ligatures and general surgery. Sterile medical device, single-use, ready to use, in a box of 12 units. List reference P122DS2430 · Code Cahnos AMP122DS2430.

2. Technical explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer widely used in surgical sutures, presented here in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration favours the passage of the thread through tissue, reduces the sawing effect, offers smooth sliding and guarantees excellent knot security, even in medium working gauges such as USP 3/0.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without causing relevant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical phase of healing, while the tissue recovers its own resistance.

The ⅜ circle needle with a 24 mm triangular reverse cutting point penetrates firm, fibrous and non-compliant tissues with controlled trauma and without tearing, which is especially suitable for skin closures, fascia, aponeurosis, ligatures and reduced surgical fields. The colourless finish minimises visual interference on the surgical field. Sterilisation by ethylene oxide (EO); does not allow re-sterilisation.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Range PREMISUT (Prime quality)
Catalogue reference P122DS2430
Code Cahnos (SKU) AMP122DS2430
Material 100 % absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 3/0 (metric 2)
Approximate thread diameter 0.20 – 0.249 mm (indicative according to USP/EP)
Thread colour Colourless (also available in violet in the range)
Thread length 75 cm
Needle shape 3/8 circle (approx. 135°)
Tip type Triangular with reverse cutting (inverted triangular)
Needle size DS24 (24 mm), 1 needle per thread
Absorption mechanism Hydrolysis (60-90 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (minimum order 30 boxes)

3.2. Tensile strength retention profile after implantation

Period Tensile strength retention
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Complete absorption 60-90 days by hydrolysis

Excellent initial tensile strength, optimal knot tying and a fully predictable and controlled absorption rate, with minimal tissue reaction.

3.3. Size equivalence

USP size Metric size Approximate diameter
3/0 2 0.20 – 0.249 mm (indicative according to USP/EP)

4. Equivalences and Cross-References

The coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) corresponds to the homologous families of the main manufacturers on the market: pure PGA is the material of the Safil (B. Braun) and Surgicryl (SMI) lines; the Vicryl (Ethicon, polyglactin 910) and Polysorb (Medtronic, Lactomer) ranges are copolymers based on glycolide, comparable by clinical category but not interchangeable 1:1 with the PGA homopolymer. References verified in public sources (official catalogues, GUDID/FDA and authorised distribution):

Manufacturer / Brand Family / Range Code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Safil® (polyglycolic acid, coated braided multifilament) C1048235 (SAFIL VIOLET 3/0 (2) 70 CM DS24) Comparable by category (not interchangeable 1:1) Verified in GUDID/FDA (DI 04038653925858): PGA material, USP 3/0 (EP 2) gauge and DS24 ⅜ circle needle with 24 mm cutting point match. They differ in colour (violet vs colourless), thread length (70 cm vs 75 cm), B. Braun’s own coating and presentation in a box of 36 units.
SMI (Surgical Materials Industries) Surgicryl® PGA (polyglycolic acid, braided multifilament coated with polycaprolactone and calcium stearate) 11201524 (violet) Comparable by category (not interchangeable 1:1) Surgicryl PGA USP 3/0 with DS 24 mm ⅜ circle needle and reverse cutting, 75 cm thread; matches in material, coating, gauge, needle and length. Only the colour differs (violet vs colourless). The colourless version from SMI (suffix U) must be confirmed with the manufacturer.
DemeTECH Corporation DemeSORB® PGA (polyglycolic acid, braided coated multifilament) PGA283024F4P (needle DFS-1, 24 mm) Comparable by category (not interchangeable 1:1) Verified in the manufacturer’s official store: material (PGA coated with polycaprolactone and calcium stearate), USP 3/0 gauge, 75 cm thread and 24 mm ⅜ circle reverse cutting needle match, in a box of 12 units. The needle is DFS-1 (DemeTECH’s own designation) versus DS24; verify exact geometry before substituting.

There is no equivalence table validated by the manufacturer for this specific configuration (PGA multifilament Prime, ⅜ circle needle DS 24 mm, triangular reverse cutting point, USP 3/0 gauge, 75 cm colourless thread); consult Cahnos’s technical department before using in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (24 mm), ⅜ curvature, point family (reverse cutting), thread length (75 cm), colour and type of coating. The cited brands belong to their respective manufacturers and are mentioned only as an equivalence reference.

5. Selection tips and variants of interest

The USP 3/0 (metric 2) gauge offers an ideal balance between initial strength and handling for tissues with moderate mechanical demand, soft tissue approximation, skin closures and ligatures. The DS 24 mm needle with triangular reverse cutting point is indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis). The colourless thread is recommended when maximum aesthetic discretion on the surgical field is sought; if maximum visibility is preferred, the violet version of the range is available.

Reference Variant
AMP122DS2430 PGA Prime, DS24, USP 3/0, colourless, 75 cm (current product)
AMP112DS2430 PGA Prime, DS24, USP 3/0, violet, 75 cm (same configuration in violet colour)
AM122DS2430 PGA standard quality, DS24, USP 3/0, colourless, 75 cm (economical alternative)
AMP122DS2420 PGA Prime, DS24, USP 2/0, colourless, 75 cm (thicker gauge for greater strength)
AMP128DS2440 PGA Prime, DS24, USP 4/0, colourless, 70 cm (finer gauge)
AMP122DS3030 PGA Prime, DS30, USP 3/0, colourless, 75 cm (longer needle)
P1L22DS2430 PGLA Prime (polyglactin 910), DS24, USP 3/0, colourless, 75 cm (absorption 56-72 days)
AMP2L22DS2430 PGLAR rapid, DS24, USP 3/0, colourless, 75 cm (absorption 40-45 days)

All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about other gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.

Additional information

Material

100 % absorbable polyglycolic acid (PGA)

Thread structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

Gauge

USP 3/0 (metric 2)

Needle shape

3/8 circle (approx. 135°)

Tip type

Triangular with reverse cutting (inverted triangular)

Needle size

DS24 (24 mm)

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P122DS2430

Indications

Tissue approximation, ligatures and general surgery

Brand / Range

PREMISUT (Prime quality)

Approximate thread diameter

0.20 – 0.249 mm

Number of needles

1 needle per suture

Absorption mechanism

By hydrolysis, 60-90 days

Tissue reaction

Minimal

Medida de aguja

DS 24

Usp

3/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture (Polyglycolic Acid) | ⅜ Circle Needle Reverse Cutting Triangular Point DS24 (24 mm) | USP Gauge 3/0 (Metric 2) | Colourless Braided Thread 75 cm | Ref. P122DS2430 | Box of 12 units”

Your email address will not be published. Required fields are marked *