We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture (Polyglycolic Acid) | 3/8 Circle Needle Reverse Cutting Triangular Point DS30 (30 mm) | USP Gauge 3/0 (Metric 2) | Colourless Fluted Thread 75 cm | Ref. P122DS3030 | Box of 12 units

Original price was: 44,90 €.Current price is: 32,60 €.

Synthetic absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality, mounted on a ⅜ circle needle with a reverse cutting triangular point (reverse cutting) of 30 mm (DS30). USP gauge 3/0 (metric 2), colourless fluted thread 75 cm with a coating of polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, single-use, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Ref. P122DS3030 · SKU AMP122DS3030 · box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 28 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP122DS3030

Description

1. Product Presentation

The PGA Prime absorbable multifilament suture is the reference solution for operating theatre services, purchasing centres and distributors seeking a synthetic absorbable suture of polyglycolic acid (PGA) with controlled absorption, excellent handling and fully predictable clinical performance. Its Prime quality guarantees a regular surface and smooth sliding that minimises tissue damage during suturing.

This presentation incorporates a ⅜ circle needle with reverse cutting triangular point (inverted triangular or reverse cutting) of 30 mm (DS30), USP 3/0 gauge (metric 2) and colourless grooved thread of 75 cm, ideal for tissue approximation, ligatures and general surgery. Sterile medical device, single-use, ready to use, in a box of 12 units. Manufacturer list reference P122DS3030 · SKU Cahnos AMP122DS3030.

2. Technical explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer widely used in surgical suturing, presented here in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces the sawing effect, offers smooth sliding and guarantees excellent knot security, even in medium working gauges such as USP 3/0.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating relevant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical phase of healing, while the tissue recovers its own resistance.

The ⅜ circle needle with reverse cutting triangular point of 30 mm penetrates firm, fibrous and non-compliant tissues with controlled trauma and without tearing, making it especially suitable for skin closures, fascia, aponeurosis, ligatures and reduced surgical fields. The colourless colour minimises visual interference on the surgical field. Sterilisation by ethylene oxide (EO); does not allow re-sterilisation.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Range PREMISUT (Prime quality)
Catalogue reference P122DS3030
SKU Cahnos AMP122DS3030
Material 100 % absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 3/0 (metric 2)
Thread colour Colourless (also available in violet in the range)
Thread length 75 cm
Needle shape 3/8 circle (approx. 135°)
Tip type Triangular with reverse cutting (inverted triangular / reverse cutting)
Needle size DS 30 mm
Absorption mechanism Hydrolysis (60-90 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (minimum order 30 boxes)

3.2. Tensile strength retention profile

Period Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %
Complete absorption 60-90 days by hydrolysis

Excellent initial tensile strength, optimal knot tying and fully predictable absorption rate, with minimal tissue reaction.

3.3. Size equivalence

USP size Metric size Approximate diameter
3/0 2 0.20 – 0.249 mm (indicative according to USP/EP)

4. Equivalences and Cross-References

The coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) corresponds to the homologous families of the main manufacturers on the market: pure PGA is the material of the Safil (B. Braun) and Surgicryl (SMI) lines; the Vicryl (Ethicon, polyglactin 910) and Polysorb (Medtronic/Covidien, Lactomer) ranges are copolymers based on glycolide, comparable by clinical category but not interchangeable 1:1 with PGA. Cross-checked references:

Manufacturer / Brand Family / Range Code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Safil® (pure polyglycolic acid, braided coated multifilament) C1048246 (box) / G1048246 Comparable by category (not interchangeable 1:1) Safil Violet USP 3/0 with 3/8 circle needle DS30 (M) of 30 mm; differs in colour (violet vs colourless), length (70 cm vs 75 cm) and coating (polyglyconate vs polycaprolactone). Configuration availability confirmed in GUDID/FDA; catalogue code B. Braun according to manufacturer’s list.
SMI (Surgical Materials Industries) Surgicryl® PGA (polyglycolic acid, braided multifilament coated with polycaprolactone and calcium stearate) 11301530U (colourless) / 11301530 (violet) Comparable by category (not interchangeable 1:1) Surgicryl PGA USP 3/0 with DS30 needle of 3/8 circle and reverse cutting of 30 mm, thread of 75 cm; matches in material, coating, gauge, needle, length and colour (the colourless version 11301530U). Configuration confirmed in official SMI sheet and authorised distributor; the exact cross-equivalence can only be validated by the technical department.

There is no equivalence table validated by the manufacturer for this specific configuration (Prime multifilament PGA, ⅜ circle needle DS 30 mm, reverse cutting triangular point, USP 3/0 gauge, colourless thread of 75 cm); consult the technical department of Cahnos before using in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (30 mm), ⅜ curvature, point family (reverse cutting), thread length (75 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned solely as a reference for equivalence.

5. Selection tips and variants of interest

The USP 3/0 gauge (metric 2) offers an ideal balance between initial strength and handling for tissues with moderate mechanical demand, soft tissue approximation, skin closures and ligatures. The DS 30 mm needle with reverse cutting triangular point is indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis). The colourless thread is recommended when maximum aesthetic discretion on the surgical field is sought; if maximum visibility is preferred, a violet version is available.

Reference Variant
AMP112DS3030 PGA Prime, DS30, USP 3/0, violet, 75 cm (same configuration in violet)
AM122DS3030 PGA standard quality, DS30, USP 3/0, colourless, 75 cm (economical alternative)
AMP122DS3020 PGA Prime, DS30, USP 2/0, colourless, 75 cm (thicker gauge for greater strength)
AMP122DS1930 PGA Prime, DS19, USP 3/0, colourless, 75 cm (shorter needle for reduced fields)
AMP122DS2430 PGA Prime, DS24, USP 3/0, colourless, 75 cm (intermediate needle)
AMP112DS3010 PGA Prime, DS30, USP 0, violet, 75 cm (higher initial strength)
AMP322DS3030 PGCL monofilament (poliglecaprone 25), DS30, USP 3/0, colourless, 75 cm (absorption 90-120 days)

All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or consultation of other gauges, lengths and colours under order, contact the technical-commercial team of Cahnos.

Additional information

Material

100 % absorbable polyglycolic acid (PGA)

Thread structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

Gauge

USP 3/0 (metric 2)

Needle shape

3/8 circle (approx. 135°)

Tip type

Triangular with reverse cutting (reverse cutting)

Needle size

DS30 (30 mm)

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P122DS3030

Indications

Tissue approximation, ligatures and general surgery

Brand

PREMISUT (Prime quality)

Metric gauge (EP)

2

Thread diameter

0.20 – 0.249 mm

Absorption mechanism

Hydrolysis

Absorption time

60-90 days

Tensile strength retention

75 % (2 wks) / 50 % (3 wks) / 40 % (4 wks)

Tissue reaction

Minimal

Medida de aguja

DS 30

Usp

3/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture (Polyglycolic Acid) | 3/8 Circle Needle Reverse Cutting Triangular Point DS30 (30 mm) | USP Gauge 3/0 (Metric 2) | Colourless Fluted Thread 75 cm | Ref. P122DS3030 | Box of 12 units”

Your email address will not be published. Required fields are marked *