We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture USP 8/0 · ⅜ Circle Spatulated Micropoint Needle DSP 6.5 mm · Violet 30 cm · Box of 12 units | Ref. P114DSP6,580

Original price was: 229,90 €.Current price is: 164,50 €.

Absorbable multifilament PGA Prime suture with ⅜ circle spatulated Micropoint needle of 6.5 mm (DSP 6.5 profile), USP gauge 8/0 (metric EP 0.4) and violet 30 cm thread, non-grooved. 100% polyglycolic acid thread with polycaprolactone and calcium stearate coating: predictable absorption by hydrolysis in 60-90 days and 75% tension retention at 2 weeks. Indicated for soft tissue approximation, ligatures, ophthalmic microsurgery and precision general surgery. Sterile by ethylene oxide, single-use, in box of 12 individual sachets. Manufacturer ref. P114DSP6,580 · SKU AMP114DSP6,580.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP114DSP6.580

Description

1. Product Presentation

The Absorbable Multifilament PGA Prime 8/0 Suture is the finest reference in the PREMISUT PRIME range for your operating theatre, ophthalmology unit or purchasing department. It features a ⅜ circle spatulated Micropoint-type needle of 6.5 mm on a braided thread of 100 % absorbable polyglycolic acid (PGA), in violet colour and 30 cm strand: the precision format for ophthalmic microsurgery, approximation of delicate lamellar tissues and closure of fine skin. Professional presentation in a box of 12 sterile units with batch traceability, ideal for supplier approval and public procurement tenders.

2. Technical Explanation

The thread is made of polyglycolic acid (PGA), a synthetic linear-chain polyester that degrades by hydrolysis with predictable kinetics: mass absorption is complete between 60 and 90 days, while tensile strength is maintained during the critical healing phase (75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks). The coating of polycaprolactone and calcium stearate reduces friction and the sawing effect on tissue, improves thread glide and facilitates knot seating with excellent knot security.

The spatulated Micropoint DSP 6.5 needle features a flat lateral edge that separates and displaces the fibres of lamellar tissues (cornea, sclera, conjunctiva, fine skin) rather than cutting them, minimising trauma and the risk of leakage. The Prime finish (non-grooved surface) optimises passage through tissue. The USP 8/0 gauge (metric EP 0.4; diameter 0.040-0.049 mm) is one of the finest thicknesses on the market and the violet colour ensures immediate visibility on the surgical field. Product sterile by ethylene oxide (EO), single-use, not re-sterilisable and conforming to USP/EP pharmacopoeias for sterile absorbable sutures.

3. Technical Specifications

Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).

3.1. General characteristics

Parameter Specification
Brand / quality PREMISUT PRIME (premium range)
Thread material Polyglycolic acid (PGA) 100 % synthetic
Structure Braided multifilament, non-grooved surface
Coating Polycaprolactone and calcium stearate
Absorption type By hydrolysis; complete mass absorption in 60-90 days
Gauge / size USP 8/0 (metric EP 0.4; diameter 0.040-0.049 mm)
Needle shape ⅜ circle (3/8 circular)
Tip type Spatulated Micropoint Spatula (DSP 6.5 Prime profile)
Needle size 6.5 mm
Swaged Single needle (1 thread with needle)
Thread length 30 cm
Thread colour Violet
Sterilisation Ethylene oxide (EO); single-use, not re-sterilisable
Indications Approximation of soft tissues, ligatures, ophthalmic surgery and microsurgery
Commercial presentation Box of 12 units (individual sterile sachets)
Storage Below 30 °C, protected from moisture and direct sunlight
Regulatory standard Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures
Manufacturer reference P114DSP6,580
SKU Cahnos AMP114DSP6,580

3.2. Tensile strength and absorption profile

Period Remaining tensile strength Absorption
2 weeks Approximately 75 % —
3 weeks Approximately 50 % —
4 weeks Approximately 40 % —
60-90 days — Complete absorption by hydrolysis

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
9/0 0.3 0.030 – 0.039 mm
8/0 (this product) 0.4 0.040 – 0.049 mm
7/0 0.5 0.050 – 0.069 mm
6/0 0.7 0.070 – 0.099 mm

4. Equivalences and Cross-References

The reference P114DSP6,580 corresponds to the official nomenclature of the PREMISUT PRIME range (DSP 6.5 profile: ⅜ circle spatulated Micropoint needle of 6.5 mm, USP 8/0 gauge, 30 cm violet thread, single needle swaged) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.

Braided polyglycolic acid with precision spatulated needle is one of the most standardised ophthalmic absorbable suture families on the market. There is no manufacturer-validated equivalence table cross-referencing this specific configuration (PGA 100%, USP 8/0, 3/8 spatulated needle of 6.5 mm, single needle, 30 cm) with references from other houses; the following rows are offered as a functional comparison verified against the manufacturer’s official catalogue or GUDID/FDA database and authorised distribution, and must be validated against the IFU before any substitution. As it is another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer).

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) COATED VICRYL® (polyglactin 910) – MICROPOINT Spatula, TG140-8 of 6.5 mm, 3/8 circle, 8-0, 30 cm, violet braided J548G (UDI-DI 10705031041134) Comparable by category (not interchangeable 1:1) They match the micropoint spatula needle of 6.5 mm in 3/8 circle, USP gauge 8/0, length 30 cm, violet colour and braided structure. They differ in material (polyglactin 910 / PGLA vs. 100% PGA), coating, absorption kinetics (56-72 days vs. 60-90 days) and, depending on distribution market, configuration (bidirectional presentations vs. single needle). Code confirmed in GUDID/FDA (Ethicon LLC) and authorised distribution.
B. Braun (Aesculap) SAFIL® Violet – braided and coated PGA, 8/0 (0.4), 30 cm, double needle DLm6S of 6 mm, 3/8 circle lancet micropoint type G1048710 Comparable by category (not interchangeable 1:1) They match the base material (polyglycolic acid), USP gauge 8/0 (EP 0.4), length 30 cm and violet colour. B. Braun does not use the term ‘spatula’: its functional equivalent is the 6 mm micropoint lancet needle (within tolerance ±0.5 mm over 6.5 mm). They differ in configuration (double needle vs. single needle), coating (glyconate vs. polycaprolactone/calcium stearate) and needle nomenclature; verify material after the commercial migration from Safil to Novosyn in some markets. Code confirmed in authorised distribution.
SMI (Steelco Medical Industries) SURGICRYL® PGA Ophthalmic – side cutting spatula, 2×DSP 6 mm, 8/0, 30 cm, violet OSU08-30 Comparable by category (not interchangeable 1:1) They match the material (braided polyglycolic acid coated with polycaprolactone and calcium stearate), USP gauge 8/0, length 30 cm, side cutting spatula needle of 6 mm (within tolerance ±0.5 mm over 6.5 mm), colour scheme and absorption kinetics (60-90 days). They differ in configuration (double needle vs. single needle) and exact needle size (6.0 mm vs. 6.5 mm). Code confirmed in official SMI datasheet.

There is no manufacturer-validated equivalence table that cross-references this specific configuration (100% PGA, 6.5 mm micropoint spatula needle in ⅜ circle, USP gauge 8/0, 30 cm thread, Prime quality, single needle) with references from other manufacturers; consult the technical department before use in tenders. Other homologous families of braided polyglycolic acid with spatula needle — e.g. Dexon II (PGA, currently Medtronic/Covidien) or the ophthalmic ranges of other European suppliers — must be reviewed property by property (material, coating, USP/metric gauge, curvature, tip family, size and number of needles, thread length, colour and CE/MDR regulatory classification) before any substitution. This needle geometry (DSP 6.5, USP 8/0, 30 cm, single needle) is only fully safely interchangeable within the PREMISUT system itself.

5. Selection tips and variants of interest

Tissue to suture: USP gauge 8/0 (metric EP 0.4, diameter 0.040-0.049 mm) is the finest gauge commonly used in microsurgery: cornea, sclera and conjunctiva in ophthalmology, fine vascular approximation, closure of thin skin and soft tissues with very low tension. The 6.5 mm micropoint spatula needle in ⅜ circle is the best option for lamellar tissues, where it dissects the plane without cutting it and reduces the risk of leakage.

Single needle configuration: this 30 cm reference with a single needle is the standard format for interrupted sutures and precision interrupted sutures. If your protocol prefers continuous suture without rethreading, the same family offers the double needle version 2×DSP 6.5 mm in 8/0 and 30 cm (SKU AMP114DSP6,580-2) and in 7/0 with 45 cm (SKU AMP111DSP6,570-2). For a slightly larger gauge with the same spatulated DSP 6.5 mounting, see the 7/0 version of 30 cm (SKU AMP114DSP6,570).

Material variants on the same needle: if an absorption profile with polyglactin kinetics is required (56-72 days instead of 60-90 days), the PREMISUT range of Polyglactin 910 offers the same spatulated DSP 6.5 mounting in 8/0 and 30 cm (SKU P1L14DSP6,580), in double needle (SKU P1L14DSP6,580-2) and in 7/0 (SKU P1L14DSP6,570 and P1L11DSP6,570-2). Remember that the polymer composition changes, so it is not interchangeable for indication purposes without clinical validation.

Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, keep the reference P114DSP6,580 together with the batch number for traceability in the operating theatre and store below 30 °C, away from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial manufacturers, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglycolic acid (PGA) 100 % synthetic

Structure

Braided multifilament, non-grooved surface (Prime)

Coating

Polycaprolactone and calcium stearate

Gauge

USP 8/0 (metric EP 0.4)

Needle type

Spatulated Micropoint Spatula

Swaged

Single needle (1 thread with needle)

Strength retention

75 % (2 weeks), 50 % (3 weeks), 40 % (4 weeks)

Sterilisation

Ethylene oxide (EO); single-use, not re-sterilisable

Presentation

Box of 12 units

Manufacturer reference

P114DSP6,580

Absorption type

By hydrolysis; complete mass absorption in 60-90 days

Thread diameter

0.040 – 0.049 mm (USP/EP Pharmacopoeia)

Needle shape

⅜ circle (3/8 circular)

Tip type

Spatulated Micropoint Spatula (DSP 6.5 Prime profile)

Needle size

6.5 mm

Indications

Approximation of soft tissues, ligatures, ophthalmic surgery and microsurgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures

Medida de aguja

DSP 6

Usp

8/0

Color

Violet

Medida de hilo

30 cm

Tipo de aguja

Spatulated

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture USP 8/0 · ⅜ Circle Spatulated Micropoint Needle DSP 6.5 mm · Violet 30 cm · Box of 12 units | Ref. P114DSP6,580”

Your email address will not be published. Required fields are marked *