Prime Absorbable Multifilament PGA Suture | 3/8 Circle Cylindrical Needle Blunt Point DRN 64 (64 mm) | USP 1 Gauge | Violet Thread 100 cm | Box 12 Units | Ref. AMP117DRN6401

Original price was: 44,90 €.Current price is: 38,90 €.

Absorbable suture of braided fluted multifilament polyglycolic acid (PGA) in Prime quality, with a ⅜ circle needle, cylindrical body and blunt atraumatic point DRN 64 of 64 mm. Violet thread of USP 1 gauge (metric 4) and 100 cm, coated with polycaprolactone and calcium stearate for smooth sliding and a firm knot. Predictable absorption by hydrolysis in 60-90 days with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterilised by ethylene oxide, single-use, indicated for approximation of soft tissues, ligatures and general surgery. Box of 12 units; minimum B2B order of 30 boxes. Ref. AMP117DRN6401.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP117DRN6401

Description

1. Product Presentation

The absorbable multifilament polyglycolic acid (PGA) suture from the Premisut range in Prime quality is the reference solution for the surgical block seeking a synthetic reabsorbable thread with predictable behaviour, excellent handling and maximum knot security. Its ⅜ circle needle, cylindrical body and blunt point of 64 mm (DRN 64 Prime) guarantees atraumatic and smooth penetration, especially indicated for tissue approximation, ligatures and general surgery. It is presented in a box of 12 units, designed for B2B supply to hospitals, clinics, distributors and purchasing centres of surgical material, with a minimum order of 30 boxes.

2. Technical explanation of the material

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a multifilament braided and fluted structure, coated with polycaprolactone and calcium stearate to favour thread slippage, reduce tissue friction and facilitate firm and secure knot tying, with low shape memory and great flexibility. Its absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, uniformly and independently of the patient’s enzymatic activity, in a predictable period of 60 to 90 days and with minimal tissue reaction. During the critical healing period it maintains 75 % of its tensile strength at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks. The blunt point needle passes through tissues separating the fibres without producing a cutting effect, minimising trauma to delicate or friable structures and reducing the risk of needlestick injury. The violet colour of the thread guarantees optimal visibility on the surgical field. Sterile product, sterilised by ethylene oxide (EO), single-use and not resterilisable.

3. Technical Specifications

Characteristic Specification
Reference (SKU) AMP117DRN6401
Factory reference P117DRN6401
Brand / Quality Premisut (Prime)
Composition 100 % Polyglycolic acid (PGA) absorbable by hydrolysis
Thread structure Multifilament braided fluted
Coating Polycaprolactone and calcium stearate
Colour Violet (also available colourless depending on presentation)
Gauge USP 1 (metric 4)
Thread length 100 cm
Swaged Single needle
Needle shape ⅜ circle
Needle body Cylindrical
Tip type Blunt point (atraumatic)
Needle reference DRN 64 Prime
Needle size 64 mm
Absorption mechanism Hydrolysis
Absorption period 60-90 days
Tissue reaction Minimal
Sterilisation Ethylene oxide (EO), single-use
Indications Approximation of soft tissues, ligatures and general surgery
Presentation Box of 12 units
Minimum order 30 boxes

Absorption and tensile strength retention profile:

Period Remaining tensile strength
2 weeks 75% of initial tensile strength
3 weeks 50% of initial tensile strength
4 weeks 40% of initial tensile strength
Total absorption 60-90 days by hydrolysis

4. Equivalences and Cross-References

Coated multifilament polyglycolic acid (PGA) is a widely established category among synthetic absorbable sutures of medium absorption, therefore this reference corresponds clinically, at category level, with homologous commercial ranges of braided PGA coated with polycaprolactone and calcium stearate and absorption by hydrolysis of 60-90 days, such as Surgicryl® PGA (SMI), AssuCryl® PGA (Assut Sutures), DemeSORB®/DemeCRYL PGA (DemeTECH) or PGA Resorba™ (Resorba), as well as with the polyglactin 910 (PGLA) families from Ethicon (Vicryl®), B. Braun (Safil®) and Medtronic (Polysorb®), which share clinical indication although they differ in composition and absorption profile.

Having verified the official documentation from manufacturer SMI (2024 technical catalogue), the Surgicryl® PGA range does not include a blunt ⅜ circle needle of 63-64 mm in USP 1 gauge; the only blunt ⅜ needle of that size documented by SMI corresponds to its Surgicryl® 910 (PGLA) line: DRB 63 mm, USP 1, 100 cm, violet, ref. 15401963, which should be considered comparable by category, not interchangeable 1:1, as it differs in composition (polyglactin 910) and absorption profile (56-72 days).

There is no equivalence table validated by the manufacturer for this reference that allows declaring a 1:1 cross-reference with a confirmed code from another manufacturer for a DRN 64 blunt point needle, USP 1 gauge, violet thread of 100 cm; consult with the technical department of Cahnos before using a formal substitution in a tender.

Within the Cahnos catalogue itself, the reference with identical needle configuration, gauge and length in polyglactin 910 (PGLA) Prime is P1L17DRN6401; the variant in standard qualities of the same product is AM117DRN6401; and the PGA Prime variants with the same needle in other lengths are AMP112DRN6401 (75 cm) and AMP113DRN6401 (90 cm).

5. Selection tips and variants of interest

Select this suture when you need a medium-high gauge (USP 1, metric 4) with high tension retention during the first weeks of healing and complete absorption between 60 and 90 days, especially indicated for soft tissues under tension, abdominal wall, plane approximation, ligatures and general surgery. The blunt point needle is the most respectful of delicate tissues, as it separates the tissue without cutting it, which reduces the risk of tearing and makes it ideal for friable structures. If you need more or less thread while keeping the same needle, you have the variants of 75 cm (AMP112DRN6401) and 90 cm (AMP113DRN6401); if you prefer a ½ circle needle with blunt point, consult reference P1L17HRN6501 (HRN 65, USP 1, 100 cm). For purchasing centres and large volumes, a minimum order of 30 boxes applies; contact the commercial department of Cahnos for institutional conditions, formalised budgets and scheduled deliveries.

Additional information

Manufacturer reference

P117DRN6401

Product line

Premisut Prime

Composition

100% Polyglycolic acid (PGA)

Coating

Polycaprolactone and calcium stearate

Gauge

USP 1 (metric 4)

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Minimum order

30 boxes

Material

100 % polyglycolic acid (PGA), multifilament braided fluted

Thread structure

Multifilament braided fluted

Thread size

100 cm

Needle body

Cylindrical

Tip type

Blunt point (atraumatic)

Needle reference

DRN 64 Prime

Needle size

64 mm

Absorption mechanism

Hydrolysis

Tensile retention

75 % (2 weeks) / 50 % (3 weeks) / 40 % (4 weeks)

Indications

Approximation of soft tissues, ligatures and general surgery

USP size

1 (metric 4)

Swaged

Single needle

Medida de aguja

DRN 64

Usp

1

Color

Violet

Medida de hilo

100 cm

Tipo de aguja

Blunt tip

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Tipo uso

Single-use

Reviews

There are no reviews yet.

Be the first to review “Prime Absorbable Multifilament PGA Suture | 3/8 Circle Cylindrical Needle Blunt Point DRN 64 (64 mm) | USP 1 Gauge | Violet Thread 100 cm | Box 12 Units | Ref. AMP117DRN6401”

Your email address will not be published. Required fields are marked *