Description
1. Commercial Introduction
The absorbable multifilament PGA suture from the PREMISUT line, reference AM118HRT4810 (factory ref. 118HRT4810), is the reference choice in the operating theatre for hospitals, private clinics, purchasing groups and wholesalers seeking a high-performance synthetic absorbable thread with excellent value for money in B2B procurement and tenders. It features a ½ circle needle with cylindrical body and trocar point (Tapercut) of 48 mm (HRT 48), USP 0 (metric 3.5) and a 70 cm fluted violet thread, ensuring precision, handling and fully predictable absorption during the first weeks of healing.
Each unit is supplied sterile and ready to use, with the warranty of professional distribution from Cahnos. Especially indicated for tissue approximation, ligatures and general surgery, where controlled penetration, knot security and minimal tissue reaction are required.
2. Technical Explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces the sawing effect, offers very smooth handling and ensures firm, secure knot tying.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating significant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical healing phase while the tissue recovers its own resistance.
The ½ circle needle with cylindrical body and trocar point (Tapercut profile) combines a rounded body that passes through tissue with minimal injury and a cutting point that allows penetration of fibrous and dense tissues (fascia, aponeurosis, muscle planes) with less effort and without enlarging the exit hole. The violet colour ensures optimal visibility on the surgical field. Sterile single-use product, not suitable for resterilisation.
3. Technical Specifications
3.1. General characteristics (Ref. 118HRT4810)
| Parameter | Specification |
| Reference (SKU Cahnos) | AM118HRT4810 |
| Factory reference | 118HRT4810 |
| Range / Quality | PREMISUT – Normal quality |
| Thread material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Violet (high visibility) |
| Thread length | 70 cm |
| Configuration | Single needle (1 needle per thread) |
| Needle shape | ½ circle (approx. 180°) |
| Needle body | Cylindrical |
| Needle tip | Trocar (Tapercut) |
| Needle size | 48 mm (HRT 48) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 sterile units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Complete absorption | 60 – 90 days by hydrolysis |
Predictable absorption by hydrolysis with minimal tissue reaction, excellent tensile strength and optimal knot tying, in accordance with USP / European Pharmacopoeia for synthetic absorbable sutures.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
Polyglycolic acid (PGA) braided multifilament coated with medium absorption (60-90 days) is one of the most widely used synthetic absorbables in general surgery and ligatures. The specific configuration of this data sheet —PGA homopolymer, ½ circle HRT 48 mm needle with trocar point (Tapercut), USP 0 gauge, 70 cm violet thread, single needle— has been compared with the main homologous families on the market:
- SMI Surgicryl® PGA: homologous family of braided PGA coated with polycaprolactone and calcium stearate, with comparable clinical behaviour. In the official catalogue (Rev. 10) the HRT 48 mm needle appears in USP 1 gauge with 90 cm thread (ref. 11400548); the USP 0 + 70 cm combination is not listed, so it is not interchangeable 1:1.
- B. Braun / Aesculap Safil®: line of braided coated PGA with a range of ½ circle needles; the coating differs (glyconate versus polycaprolactone and calcium stearate), so it is not interchangeable 1:1.
- Ethicon / Johnson & Johnson MedTech Coated VICRYL® (polyglactin 910): copolymer range with a shorter absorption profile (56-72 days) and different chemistry from PGA homopolymer; comparable by category, not interchangeable 1:1 without technical validation.
- DemeTECH DemeSORB® PGA: homologous family of braided coated PGA with ½ circle needles; no closed code has been confirmed in official sources for this exact configuration (USP 0 + 48 mm trocar + 70 cm).
- Medtronic / Covidien Polysorb®: absorbable braided range with copolymer base (Lactomer); confirm exact point, gauge and geometry in tender.
There is no manufacturer-validated equivalence table that cross-references this specific reference (PGA USP 0, ½ circle HRT 48 mm needle with trocar point, 70 cm violet thread) with closed codes from other brands; consult the technical department before using in a tender. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (48 mm), ½ curvature, point family (trocar/tapercut), thread length (70 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference. Within the Cahnos catalogue, the closest equivalent by needle geometry, gauge, colour and length is reference AMP118HRT4810 (Prime range, same HRT 48 mm trocar needle); in PGLA material (polyglactin 910, absorption 56-72 days) consult reference 1L18HRT4810 with the same needle geometry.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the gauge needed according to the anatomical area. USP 0 gauge (metric 3.5) is indicated for tissues with moderate tension: muscle planes, aponeurosis, fascia and ligatures in general and digestive surgery. The ½ circle needle with trocar point (Tapercut) combines penetration and control in firm tissues; for soft and friable tissues, conical points (HR/Taperpoint) are recommended, and for very delicate structures, reverse cutting points (HS).
| Reference | Variant of interest |
| AM118HRT4810 | PGA USP 0, ½ trocar HRT 48 mm needle, violet, 70 cm (current product) |
| AMP118HRT4810 | PGA Prime USP 0, same HRT 48 mm trocar needle, violet, 70 cm (premium range) |
| AM118HR4010 | PGA USP 0, ½ circle taper needle HR 40 mm, violet, 70 cm (more atraumatic for soft tissue) |
| AM113HR4810 | PGA USP 0, ½ circle taper needle HR 48 mm, violet, 90 cm (longer thread length) |
| AM112HR4810 | PGA USP 0, ½ circle taper needle HR 48 mm, violet, 75 cm (intermediate thread) |
| 1L18HRT4810 | PGLA (polyglactin 910) USP 0, HRT 48 mm trocar needle, violet, 70 cm (absorption 56-72 days) |
If you need longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos; for faster absorption, see the fast-absorption range (PGLAR type). All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalents from other manufacturers, contact our technical-commercial team.