Description
1. Product Presentation
At Cahnos we make available to you the multifilament absorbable suture of polyglycolic acid (PGA), factory reference 112HR3620 (SKU AM112HR3620) from the Premisut range. It is the professional choice for general surgery departments and procedures requiring secure, manageable closure with controlled absorption. It combines a ½ circle needle with cylindrical body and conical point (taperpoint) of 36 mm, a violet fluted thread of 75 cm in USP 2/0 gauge and an economical presentation in a box of 12 units, designed for hospital supply, purchasing centres and tenders. A synthetic, sterile, single-use medical device with an excellent quality-price ratio for the continuous supply of your centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This architecture regularises the surface of the thread, reduces friction when passing through tissues, improves sliding and guarantees firm, secure knot tying even in fine working gauges such as USP 2/0.
Absorption occurs by hydrolysis —a predictable mechanism independent of the patient’s enzymatic activity— over a period of 60 to 90 days, maintaining tensile support during the first 2 to 4 weeks of healing while the tissue recovers its own strength. The ½ circle needle with cylindrical body and conical point (taperpoint) penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is therefore especially indicated for approximation of soft tissues, ligatures and general surgery. The violet colour of the thread ensures optimal visibility on the surgical field. Product sterilised by ethylene oxide, single-use and with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference 112HR3620
| Reference (SKU Cahnos) | AM112HR3620 |
| Factory reference | 112HR3620 (Premisut nomenclature) |
| Thread material | 100% polyglycolic acid (PGA), absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 2/0 (metric 3), in accordance with USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread colour | Violet (grooved) |
| Thread length | 75 cm |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | HR 36 (36 mm), 1 needle per thread |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60–90 days, by hydrolysis (predictable rate) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The diameter of the strand complies with the official ranges of the USP/EP Pharmacopoeia for synthetic absorbable sutures, without exceeding its limits.
3.4. Decoding of the official reference
The official reference 112HR3620 is decoded as: 112 (violet thread of 75 cm) + HR36 (½ circle needle with cylindrical body and conical taperpoint point of 36 mm) + 20 (USP 2/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the most well-established medium-duration braided multifilament absorbable on the market and shares an absorption profile (60–90 days), coated braided structure and clinical behaviour with homologous families in the sector. There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following matches are functional comparisons at category level and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® (braided coated polyglactin 910, violet) | J345H – USP 2/0, CT-1 needle of 36 mm, ½ circle, conical point, 90 cm | Comparable by category (not interchangeable 1:1) | Code verified in Ethicon’s official catalogue and authorised distribution: USP 2/0 gauge, ½ circle curvature, 36 mm conical needle and violet colour match. They differ: polymer (polyglactin 910 versus 100% PGA), absorption profile (56–72 days versus 60–90 days), thread length (90 cm versus 75 cm) and presentation (box of 36 units versus 12 units). |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Homologous ranges in the medium-absorption braided PGA segment include Dexon (Medtronic/Covidien), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH) and Atramat (Resorba), as well as the polyglactin 910 lines Coated VICRYL® / VICRYL® Plus (Ethicon), Safil (B. Braun), Polysorb (Medtronic) and Assucryl 910 (Assut Sutures), comparable by category by material and absorption profile; for the exact combination USP 2/0 / HR 36 mm conical point needle / 75 cm in violet, their specific codes must be confirmed with the manufacturer before any substitution, verifying material, gauge, curvature, needle type and size, thread length, colour and attachment. This geometry (HR36, USP 2/0, 75 cm) is fully interchangeable only within the Premisut system itself from Cahnos.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) offers an optimal balance between strength and fineness, indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures of medium-calibre vessels. The HR36 ½ circle needle with conical point (taperpoint) is atraumatic and ideal for soft and delicate tissues; if you need to pass through firmer, denser tissues (skin, fascia, sclera), consider the reverse cutting (HS) or trocar (HRT) points available in the same range.
| Variant / Reference | Description |
| AM112HR3620 (112HR3620) | PGA – HR36 conical point – USP 2/0 violet – 75 cm (this product) |
| AM113HR3620 (113HR3620) | PGA – HR36 conical point – USP 2/0 violet – 90 cm (longer thread length) |
| AM123HR3620 (123HR3620) | PGA – HR36 conical point – USP 2/0 colourless – 90 cm (same geometry, maximum discretion in the field) |
| AMP112HR3620 (P112HR3620) | PGA Prime – HR36 conical point – USP 2/0 violet – 75 cm (same geometry, Prime quality) |
| AM112HR2620 (112HR2620) | PGA – HR26 conical point – USP 2/0 violet – 75 cm (shorter needle, superficial planes) |
| AM112HR3630 (112HR3630) | PGA – HR36 conical point – USP 3/0 violet – 75 cm (finer gauge) |
| 1L12HR3620 | PGLA polyglactin 910 – HR36 conical point – USP 2/0 violet – 75 cm (absorption 56–72 days) |
The violet colour offers maximum visibility in the surgical field; if you require aesthetic discretion in superficial areas, request the same configuration in colourless thread. If you need longer strength retention (180–210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep the reference 112HR3620 together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews