Description
1. Commercial Introduction
The Multifilament Absorbable PGA Prime Heavy Suture, reference AMP112HR4801H, is the reference surgical closure solution for hospitals, general surgery operating theatres, private clinics and B2B purchasing centres that need a high-performance synthetic absorbable thread with a very competitive price-quality ratio. This presentation combines a ½ circle needle with cylindrical body and taper point of 48 mm (HR 48), USP gauge 1 and fluted violet thread of 75 cm.
Each unit is supplied sterile and ready to use, with the guarantee of professional distribution from Cahnos. Its Prime Heavy design ensures superior performance in procedures requiring high safety and reliability: tissue approximation, ligatures, deep planes and general surgery.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, very smooth handling, low memory and a firm and secure knot tie, even in larger diameter gauges such as USP 1.
Absorption occurs by hydrolysis, i.e., degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, without depending on the patient’s enzymatic activity. The thread maintains 75 % of tensile strength at 2 weeks, 50 % at 3 and 40 % at 4, an ideal profile for tissues requiring support for 2 to 4 weeks of healing.
The ½ circle needle with cylindrical body and taper point penetrates by separating the fibres without cutting them, minimising trauma to soft tissues; the fluted violet colour ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet of the reference
| Characteristic | Specification |
| Reference (SKU Cahnos) | AMP112HR4801H (manufacturer ref. P112HR4801H) |
| Range / Quality | PREMISUT, Prime Heavy quality |
| Material | 100 % Polyglycolic acid (PGA) multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament with grooved finish |
| Colour | Violet (also available colourless) |
| Gauge | USP 1 (metric 4) |
| Thread length | 75 cm (1 strand) |
| Needle shape | ½ circle (1/2) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 48 mm (HR 48 Heavy Prime) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60–90 days |
| Sterilisation | Ethylene oxide (EO), single-use, not for re-sterilisation |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Total absorption | 60–90 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a completely predictable absorption rate.
3.3. Presentation and ordering conditions
| Value | Value |
| Presentation | Box of 12 units (individual sterile unit) |
| Minimum order | 30 units |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
The polyglycolic acid (PGA) suture belongs to the family of medium-absorption braided synthetic absorbable sutures. By polymer composition (PGA homopolymer), braided structure, coating, hydrolysis absorption profile (60–90 days) and tensile retention, it is comparable at category level (not 1:1 interchangeable) with international market lines: Ethicon (Johnson & Johnson) with its Coated VICRYL / VICRYL Plus range (coated braided polyglactin 910, violet; differs in PGLA 90/10 copolymer material vs PGA homopolymer and in absorption window 56–72 days), B. Braun with Safil (violet braided PGLA), Medtronic / Covidien with Polysorb, SMI with Surgicryl, Assut with Assucryl 910 and Laboratorio Aragó (HR/TC needle series of ½ circle cylindrical).
There is no equivalence table validated by the manufacturer that cross-references these brands for the taper point needle configuration HR 48 mm, USP gauge 1 and 75 cm thread; the lines mentioned are provided as a functional category comparison and must be verified field by field (gauge, thread length, needle radius and coating) before any formal substitution in tenders. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
Within the same manufacturer and family PREMISUT, references with equivalent or very similar configuration are: P112HR4801H (official manufacturer reference for this same configuration, direct equivalent of SKU AMP112HR4801H), AM112HR4801H (PGA Heavy Normal quality, same needle HR 48 mm, same gauge, colour and length; differs only in Normal quality vs Prime Heavy), AMP112HR4802H (same needle and length with USP gauge 2 for greater traction) and AMP112HR4001H (same quality and gauge with HR 40 mm needle for more limited access fields).
5. Selection tips and variants of interest
USP gauge 1 (metric 4) is indicated for tissues requiring high initial resistance: aponeurosis, fascia, muscle planes and high-tension closures. The taper point separates fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is a blunt point, while for fibrous and dense structures a trocar point is recommended.
Check the needle radius (HR 30, 40, 45 or 48 mm) according to the depth and surgical area to be treated. Within the PGA Prime family from Cahnos, variants of this configuration are available: AMP112HR4802H (USP 2), AMP112HR4501H (HR 45 mm), AMP112HR4001H (HR 40 mm), AMP112HR3001H (HR 30 mm) and AMP112HR4820 (USP gauge 2/0). If you prefer a polyglactin 910 alternative with an absorption window of 56–72 days, consult the PGLA Prime Heavy family from Cahnos. For longer force retention needs (180–210 days), the polydioxanone (PDO) family is the recommended alternative.
As a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. Consult our technical-commercial team for special volume conditions: minimum order of 30 units, with scheduled deliveries for hospitals, clinics and purchasing centres.





Reviews
There are no reviews yet.