Description
1. Commercial Introduction
At Cahnos we make available to you the absorbable multifilament polyglycolic acid (PGA) suture in Prime quality, factory reference P128HR2630 (SKU AMP128HR2630) from the range of synthetic absorbable sutures: the professional choice for general surgery departments and procedures requiring a secure, manageable closure with controlled absorption.
This presentation combines a ½ circle needle with a cylindrical body and 26 mm Taperpoint conical point (HR26 profile), a 70 cm undyed fluted thread in USP 3/0 gauge and an institutional supply format in a box of 12 units, with a minimum order of 30 boxes, designed for operating theatres, purchasing centres, distributors and tenders for surgical material. A synthetic, sterile, single-use medical device with an excellent value for money for the continuous supply of your centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic homopolymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This architecture regularises the surface of the thread, reduces friction when passing through tissues (reduced sawing effect), improves sliding and guarantees firm, secure knot tying, even in fine gauges such as USP 3/0.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, completed within 60 to 90 days. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing (75% at 2 weeks, 50% at 3 and 40% at 4), the precise time for the tissue to recover its own resistance. The ½ circle needle with cylindrical body and conical point (Taperpoint) penetrates by separating the fibres without cutting effect, minimising trauma to delicate structures; the undyed colour of the thread offers maximum aesthetic discretion in the surgical field. Product sterile by ethylene oxide (EtO), single-use and with no possibility of resterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference P128HR2630 (SKU AMP128HR2630)
| Parameter | Specification |
| Factory reference | P128HR2630 (official nomenclature, Prime range) |
| Reference Cahnos (SKU) | AMP128HR2630 |
| Range / quality | Prime (premium range of absorbable sutures) |
| Thread material | 100% polyglycolic acid (PGA), synthetic absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 3/0 (metric 2), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread colour | Colourless (fluted); violet version available in the family |
| Thread length | 70 cm (1 needle per suture) |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | HR 26 Prime (26 mm) |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile after implantation
| Period after implantation | Retained tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis (predictable rate) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable and uniform absorption rate.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The strand diameter complies with the official USP/EP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding their limits.
3.4. Decoding of the official reference
The official reference P128HR2630 is decoded as: P (Prime range) + 128 (undyed 70 cm thread series) + HR26 (½ circle needle with cylindrical body and 26 mm Taperpoint conical point) + 30 (USP 3/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Braided and coated multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. The following homologous references have been cross-checked in public sources (authorised distribution catalogue and official manufacturer catalogue) and match this product’s HR26 configuration in material, gauge, needle geometry and needle size:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Safil® – braided coated multifilament PGA, USP 3/0 (metric 2), HR26 cylindrical ½ circle needle | C1048041 (Safil 3/0 (2) 70 cm HR26 (M)) | Comparable by category (not interchangeable 1:1) | Confirmed in official B. Braun catalogue: material (PGA), braided and coated multifilament structure, USP 3/0 gauge, 70 cm length, ½ circle shape and 26 mm HR26 cylindrical needle all match. They differ in colour (violet vs undyed) and commercial coating; validate in the technical data sheet/IFU before substituting in a tender. |
| SMI (Surgical Materials Industries, Belgium) | Surgicryl® PGA – braided coated multifilament polyglycolic acid | SM1120 0126 (HR 26 needle, 26 mm, ½ circle, round body, Taperpoint conical point) | Comparable by category (not interchangeable 1:1) | Authorised distribution catalogue: material (PGA coated with polycaprolactone and calcium stearate), USP 3/0 gauge (EP 2), ½ circle curvature, cylindrical body with conical point and 26 mm needle size all match. They differ in commercial needle nomenclature, colour (violet in the standard version) and presentation; it is not interchangeable 1:1 without prior validation by the technical department. |
There is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; consult the technical department before using it in a tender. The equivalences indicated are functional category comparisons, not interchangeable 1:1. Other homologous PGA families to be verified case by case in their official data sheet: DemeTECH DemeSORB® PGA, Assut Assucryl® PGA, Atramat® / Resorba® PGA and the historic Dexon® II. Copolymer polyglactin 910 (PGLA) ranges, such as Coated VICRYL® (Ethicon), Safil® 910 / Novosyn® (B. Braun) or Polysorb® (Medtronic), are chemically different from PGA homopolymer (56-72 days absorption vs 60-90 days) and should not be treated as interchangeable 1:1 without validation by the pharmacy service or the technical department. This geometry (HR26, USP 3/0, 70 cm) is fully safely interchangeable only within Cahnos’s own Prime family reference system.
5. Selection tips and variants of interest
The USP 3/0 (metric 2) gauge offers an ideal balance between initial strength and handling for soft and medium-consistency tissues: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as ligation of small-calibre vessels. The HR26 ½-circle needle with Taperpoint conical point is atraumatic and ideal for soft or friable tissues where a passage without cutting effect is sought; if the tissue is firm (skin, fascia, aponeurosis), consider the reverse-cutting triangular point (HS) or trocar (HRT) variants from the same range, and if you prefer a larger needle radius for deep planes, the HR36. The colourless colour offers maximum discretion in the surgical bed; if you prefer greater visibility of the thread or needle, request the violet or VisiBlack versions of the family. Consult the variants in the Cahnos catalogue to adjust gauge, geometry, colour and length to each procedure:
| Reference | Variant of interest |
| AMP128HR2630 (P128HR2630) | PGA Prime – HR26 conical point – USP 3/0 colourless – 70 cm (this product) |
| AM128HR2630 | PGA standard quality – HR26 conical point – USP 3/0 colourless – 70 cm (economical alternative, same geometry) |
| AMP128HR2630VB | PGA Prime – HR26 conical point – USP 3/0 colourless – 70 cm with VisiBlack needle (maximum needle contrast) |
| AMP118HR2630VB | PGA Prime – HR26 conical point – USP 3/0 violet – 70 cm VisiBlack (maximum thread and needle visibility) |
| AMP113HR2630 / AMP112HR2630 | PGA Prime – HR26 conical point – USP 3/0 violet – 90 cm / 75 cm (other thread lengths) |
| AMP128HR2620 / AMP128HR2610 | PGA Prime – HR26 conical point – USP 2/0 / USP 0 colourless – 70 cm (larger gauges, higher strength) |
| AMP128HR2230 / AMP128HR3630 | PGA Prime – conical point – USP 3/0 colourless – 70 cm with HR22 (22 mm) / HR36 (36 mm) needle |
| P1L28HR2630VB | PGLA (polyglactin 910) Prime – HR26 VisiBlack – USP 3/0 colourless – 70 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. If you need a longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep the reference P128HR2630 together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or validation of equivalences with other commercial houses, contact our technical-commercial team at Cahnos.





Reviews