Absorbable Multifilament PGA Prime Suture | Needle 1/2 Circle Cylindrical Body Conical Taperpoint Point 10 mm (HR10) | USP Gauge 5/0 (Metric 1) | Violet Fluted Thread 70 cm | Box of 12 units | Ref. AMP118HR1050

Original price was: 76,97 €.Current price is: 42,75 €.

Multifilament absorbable suture of polyglycolic acid (PGA) in Prime quality, mounted on an atraumatic needle of 1/2 circle, cylindrical body and conical Taperpoint point of 10 mm (HR10). USP gauge 5/0 (metric 1), violet fluted thread of 70 cm, with predictable hydrolysis absorption between 60 and 90 days and tensile strength retention: 75% at 2 weeks, 50% at 3 and 40% at 4. Coating of polycaprolactone and calcium stearate, minimal tissue reaction and excellent knot security. Sterile by ethylene oxide (EO), single-use and non-resterilizable. Indicated for tissue approximation, ligatures and general surgery; presentation in a box of 12 units with a minimum order of 30 boxes and B2B conditions for hospitals and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP118HR1050

Description

1. Product Presentation

The absorbable multifilament suture of Polyglycolic Acid (PGA) from Cahnos, in Prime quality, is the synthetic reabsorbable solution designed for the professional who demands predictable behaviour, excellent tensile strength and great security in knot tying. Its 1/2 circle needle, cylindrical body and Taperpoint conical point of 10 mm (HR10) guarantees smooth and controlled penetration in soft tissues, minimising tissue trauma.

It is the ideal choice for tissue approximation, ligatures and general surgery, in a professional box format of 12 units, ideal for stock management in operating theatres and purchasing centres, with special B2B conditions for hospitals and volume buyers (minimum order 30 boxes).

2. Technical explanation of the material and procedure

Polyglycolic Acid (PGA) is a synthetic absorbable polymer with excellent initial resistance, presented in a braided multifilament structure that provides great flexibility, smooth passage through tissue and excellent knotting behaviour. The thread incorporates a coating of polycaprolactone and calcium stearate that reduces the drag effect, facilitates sliding and minimises tissue reaction.

Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, which guarantees a predictable loss of mass between 60 and 90 days. The 1/2 circle needle with cylindrical body and conical point (Taperpoint geometry) combines an atraumatic point, which separates the fibres without cutting effect, with smooth passage through tissue: the usual configuration in the approximation of delicate and precise tissues. The fluted violet colour of the thread guarantees optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

Technical data sheet for reference AMP118HR1050:

Parameter Specification
Reference (SKU) AMP118HR1050
Factory reference P118HR1050
Quality / Brand Prime · Cahnos
Suture type Synthetic absorbable multifilament
Material 100 % Polyglycolic Acid (PGA)
Thread structure Braided multifilament, grooved
Coating Polycaprolactone and calcium stearate
USP / metric gauge 5/0 (metric 1)
Approximate diameter 0.100 – 0.149 mm (USP/EP standard)
Thread length 70 cm
Thread colour Fluted violet
Needle shape 1/2 circle
Needle body Cylindrical
Needle tip Atraumatic conical (Taperpoint)
Needle size 10 mm (HR10 Prime)
Absorption type By hydrolysis, between 60 and 90 days
Sterilisation Ethylene oxide (EO), sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units · Minimum order 30 boxes
Regulatory standard USP/EP

Tensile strength retention and absorption profile:

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60-90 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Polyglycolic Acid (PGA) in a coated braided structure is one of the most well-established synthetic absorbable suture raw materials on the market. This Prime reference is clinically comparable, in chemical composition (PGA), needle geometry (1/2 circle, cylindrical body, Taperpoint conical point), gauge (USP 5/0) and thread length (70 cm), with the main international lines:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
B. Braun Safil® Violet (braided coated polyglycolic acid, violet) G1048003 – Safil Violet 5/0 (1) 70 cm HR10 (verified in GUDID, DI 04038653943944, and B. Braun catalogue) Comparable by category (not interchangeable 1:1) Same 100% PGA, same USP 5/0 gauge (metric 1), same thread length (70 cm) and same HR10 needle geometry (1/2 circle, cylindrical body, conical point); the coating is glyconate versus polycaprolactone/calcium stearate and the retention profile differs (≈50% at 18 days). Box of 12 units.
SMI (Belgium) Surgicryl® PGA (braided coated polyglycolic acid, violet) 11100113 – USP 5/0, 1/2 circle needle, round body, conical point HR 13 mm, 75 cm, violet (official SMI catalogue, Rev. 10) Comparable by category (not interchangeable 1:1) Same polymer (PGA) and same coating (polycaprolactone and calcium stearate at 1%), same absorption 60–90 days; they differ in needle size (13 mm vs 10 mm) and strand length (75 cm vs 70 cm). Box of 12 units.

There is no equivalence table validated by the manufacturer for this reference; the correspondences indicated are functional comparisons verified against official sources (manufacturer’s catalogue and GUDID database) and must be confirmed with the technical department before use in tendering or formal substitution of references. At category level, they are also homologous lines of coated braided PGA: DemeTECH DemeSORB® PGA, Assut Sutures AssuCryl® PGA and the historical Medtronic Dexon®/Dexon II® range; the poliglactin 910 lines (e.g. Ethicon Vicryl® or Polysorb®) share the multifilament behaviour but use a different copolymer with absorption of 56–72 days, so they are not interchangeable 1:1 material to material.

5. Selection tips and variants of interest

The USP 5/0 gauge (metric 1) is indicated for fine and low-tension tissues: mucosa, subcutaneous tissue, delicate planes and precision approximations. The 1/2 circle conical point needle of 10 mm (HR10) is the most atraumatic option for these tissues and smaller radius accesses. Within the Cahnos catalogue, the following variants of interest are offered:

  • P1L18HR1050: same HR10 configuration, USP 5/0, violet thread 70 cm, in Poliglactin 910 (PGLA) with absorption of 56-72 days, to compare suppliers and consolidate stock.
  • P1L18HRP1050: same HR10 needle and gauge, with Ultra Plus trocar conical point (greater penetration capacity in firmer tissues).
  • AMP112HR1350: in PGA, HR 13 mm needle and 75 cm thread, same gauge 5/0 (larger needle arc).
  • AMP118HR1330 / AMP118HR1340 / AMP118HR1320 / AMP118HR1310: same PGA family with HR 13 mm needle in gauges 3/0, 4/0, 2/0 and 0, violet, 70 cm (different tension depending on tissue).
  • AM118HR1050: same configuration in standard quality (factory reference 118HR1050), for protocols with equivalent requirements and cost optimisation.

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalents from other commercial brands, contact our technical-commercial team.

Additional information

Material

100 % polyglycolic acid (PGA)

Coating

Polycaprolactone and calcium stearate

Gauge

USP 5/0 (metric 1)

Thread colour

Fluted violet

Strength retention

75% at 2 weeks, 50% at 3 weeks, 40% at 4 weeks

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P118HR1050

Suture type

Absorbable synthetic multifilament

Thread structure

Braided multifilament, grooved

Metric gauge (EP)

1

Thread diameter

0.100 – 0.149 mm (USP/EP standard)

Needle body

Cylindrical

Needle tip

Conical Taperpoint, atraumatic

Needle size

10 mm (HR 10)

Absorption mechanism

Hydrolysis

Tissue reaction

Minimal

Regulatory standard

USP/EP

Medida de aguja

HR 10

Usp

5/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Estructura hilo

Braided multifilament

Absorcion

Absorbable medium (46–120 days)