We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) – ½ Circle Cylindrical Body Blunt Point Needle HRN 48 mm – USP Gauge 0 – Violet Fluted Thread 90 cm – Ref. AM113HRN4810

Original price was: 30,24 €.Current price is: 23,20 €.

Absorbable multifilament suture of polyglycolic acid (PGA) 100 %, mounted on a ½ circle needle, cylindrical body and atraumatic blunt point of 48 mm (HRN 48). USP gauge 0 (metric 3.5), violet braided fluted thread of 90 cm coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 40 % at 4. Sterilised by ethylene oxide, single-use and with minimal tissue reaction. Indicated for tissue approximation, ligatures and general surgery. Presentation in box of 12 units; minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM113HRN4810

Description

1. Commercial Introduction

The multifilament absorbable suture made of polyglycolic acid (PGA), reference AM113HRN4810, is the surgical closure solution your facility needs when a reliable, flexible synthetic absorbable thread with fully predictable absorption behaviour is required. It combines a ½ circle cylindrical-bodied needle with a blunt point of 48 mm (HRN 48) and a 90 cm violet fluted braided thread in USP 0 gauge, designed for the approximation of soft tissues, ligatures and medium-tension closures in general surgery.

It is a synthetic absorbable medical device, sterile and single-use, presented in B2B format in a box of 12 units with a minimum order of 30 boxes, ensuring continuous and traceable supply for hospitals, clinics, operating theatres, distributors and purchasing centres.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer composed of 100% glycolide units, presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory and a contained friction coefficient, which favours the sliding of the thread through tissue, manageability and a firm, secure knot tying, with high initial tensile strength.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity and with minimal tissue reaction: the polymer degrades into glycolic acid, which the body metabolises without generating a relevant response. The thread retains 75% of tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues requiring support during 2 to 4 weeks of healing.

The ½ circle needle with cylindrical body and blunt point of 48 mm passes through tissues separating the fibres without cutting effect, minimising trauma to delicate and friable structures. The violet colour of the thread ensures optimal visibility on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference AM113HRN4810

Reference (SKU) AM113HRN4810
Range / Quality Premisut, Normal quality
Material 100% polyglycolic acid (PGA), absorbable by hydrolysis
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 0 (metric 3.5), conforming to USP/EP Pharmacopoeia
Thread colour Grooved violet (also available undyed)
Thread length 90 cm, 1 needle per thread
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Roma (blunt point), atraumatic
Needle size HRN 48 mm
Absorption mechanism Hydrolysis, completed between 60 and 90 days
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile sachets); minimum order of 30 boxes
Regulatory standard Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60-90 days, by hydrolysis

Excellent resistance during the critical healing period, smooth passage through tissues, uniform and atraumatic surface, secure knotting and comfortable handling. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
2/0 3 0.30 – 0.349 mm
0 (this product) 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm
2 5 0.50 – 0.599 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding its limits.

4. Equivalences and Cross-References

Braided polyglycolic acid (PGA) with 60-90 days of absorption is one of the most well-established medium-absorption synthetic multifilament absorbable suture raw materials on the international market. No closed and confirmed code from another manufacturer has been found in official sources for the exact configuration of this reference (½ circle needle, cylindrical body, blunt point HRN 48 mm, USP 0 gauge, 90 cm violet thread).

At family level, the homologous reference lines in the sector are those of 100% coated braided PGA —Safil (B. Braun), Dexon II (Medtronic/Covidien), Surgicryl PGA (SMI) and DemeSORB PGA (DemeTECH)— and those of poliglactin 910 copolymer —Coated Vicryl / Vicryl Plus (Ethicon), Polysorb (Medtronic) and Novosyn (B. Braun)—. All are comparable at category level (same type of base polymer and absorption profile) but not interchangeable 1:1: for any formal substitution, the polymer and coating, USP 0 gauge, the configuration (single needle), the ½ circle curvature, the point family (blunt, blunt point), the 48 mm needle size and the 90 cm thread length must be verified one by one, since small variations in radius or point profile prevent direct equivalence. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and ligatures of medium-calibre vessels, with an excellent balance between initial resistance and predictable absorption during a 2 to 4 week healing period. The blunt point (HRN) is the most atraumatic option for delicate and friable tissues; if you need greater ease of penetration in somewhat denser tissues, consider the conical point version (HR 48) from the same PGA family, and for fibrous structures the trocar point (HRT).

Reference (SKU) Variant of interest
AM113HRN4810 PGA USP 0, blunt point HRN 48 mm, violet, 90 cm (current product)
AMP113HRN4810 PGA Prime USP 0, same HRN 48 mm needle, violet, 90 cm (superior quality)
AM113HRN4801 PGA USP 1, same HRN 48 mm needle, violet, 90 cm (higher resistance)
AM113HR4810 PGA USP 0, conical point HR 48 mm, violet, 90 cm (soft tissues)
AM113HRN4010H PGA USP 0, blunt point HRN 40 mm Heavy, violet, 90 cm (reinforced smaller radius)
1L13HRN4810 Polyglactin 910 USP 0, same HRN 48 mm needle, violet, 90 cm (56-72 day absorption)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is sterile single-use material, always check the integrity of the packaging before each procedure, respect the expiry date and store in a cool, dry place, protected from sunlight. If the procedure requires longer wound support (180-210 days), the polydioxanone (PDO) family is the recommended alternative. For special B2B volume conditions, hospital supply contracts or confirmation of equivalences for tenders, contact the technical-commercial team at Cahnos.

Additional information

Material

100% polyglycolic acid (PGA), absorbable by hydrolysis

Thread structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

Gauge

USP 0 (metric 3.5)

Thread colour

Violet grooved

Needle body

Cylindrical

Needle tip

Roma (blunt point), atraumatic

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO); single-use, non-reesterilizable

Presentation

Box of 12 units; minimum order of 30 boxes

Indications

Tissue approximation, ligatures and general surgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia

Medida de aguja

HRN 48

Usp

0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Blunt tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) – ½ Circle Cylindrical Body Blunt Point Needle HRN 48 mm – USP Gauge 0 – Violet Fluted Thread 90 cm – Ref. AM113HRN4810”

Your email address will not be published. Required fields are marked *