Description
1. Commercial Introduction
The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference choice when the operating theatre needs a thread with prolonged support, predictable behaviour and maximum security in knot tying. This presentation combines a violet 70 cm thread in USP gauge 3/0 with a straight 60 mm needle and triangular point in conventional cutting (GS60), a configuration designed for firm, controlled penetration in tissues requiring a direct pass without curvature, very common in open surgery on accessible planes.
Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking consistent quality and full traceability in each package.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity. This guarantees highly reproducible absorption kinetics between individuals and minimal tissue response, with complete absorption within 180 to 210 days: one of the longest support windows among absorbable sutures.
Being a non-grooved monofilament, the thread has no wicking effect or interstitial spaces: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory reaction compared to braided threads. The straight needle with triangular conventional cutting point has three cutting edges that traverse firm, fibrous tissues in a straight path, without needing to rotate the wrist; ideal for superficial planes, fascia and accessible structures in direct field. The violet colour improves thread visibility on the surgical field. Sterile single-use product, not resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference AM418GS6030
| Parameter | Specification |
| SKU | AM418GS6030 |
| Material | Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone), non-grooved |
| Thread structure | Monofilament, non-braided |
| USP / metric gauge | USP 3/0 (metric 2) |
| Thread length | 70 cm |
| Thread colour | Violet (high visibility) |
| Needle shape | Straight |
| Needle tip | Triangular, conventional cutting |
| Needle size | GS60 – 60 mm, one needle per suture |
| Absorption mechanism | Hydrolysis (180-210 days) |
| Sterilisation | Ethylene oxide (EO); single-use, non-reesterilizable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75% of initial strength |
| 4 weeks | 60-70% of initial strength |
| 8 weeks | 45% of initial strength |
| Complete absorption | 180-210 days by hydrolysis |
This prolonged strength retention profile maintains the necessary support during the critical healing phase of slow-healing tissues, which is why it is recommended for closures of fascia, aponeurosis and structures subjected to sustained tension, as well as in paediatric cardiovascular surgery where tissue growth is expected.
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market-leading lines for long-lasting absorbable sutures (PDS-type family). On the verified configuration of this data sheet (straight needle with triangular conventional cutting point of 60 mm, USP gauge 3/0, violet 70 cm thread), a verified homologous market reference has been located in primary sources with which it shares material and measurements:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson) | PDS II® (polydioxanone, monofilament) | Z663H | Comparable by category (not interchangeable 1:1) | USP gauge 3/0 and straight 60 mm needle with 70 cm thread, but it is marketed undyed (clear), with a straight KS reverse cutting needle versus the conventional GS cutting of this reference and presentation in a box of 36 units. Verify point, colour and packaging before substituting. |
As homologous market families to verify code by code before any substitution: the PDS II® and PDS Plus® lines from Ethicon, the MonoPlus® line from B. Braun/Aesculap (polydioxanone monofilament), the Surgicryl® PDO line from SMI and the Maxon range (polyglyconate) from Medtronic. It should be noted that, in Ethicon’s official catalogue, the straight cutting needle of the PDS II family (model KS, 60 mm, 70 cm) is only marketed in undyed colour and in USP gauges 3/0 and 4/0 (refs. Z663H and Z662H), so it is not interchangeable 1:1 with this violet reference. There is no equivalence table validated by the manufacturer for this configuration; consult the technical department before use in tenders. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue and moderate tension planes, and USP 1 and above for fascia, aponeurosis and structures under high tension. The needle shape is also decisive: the straight needle is handled directly with the hand or straight needle holder and is especially practical in superficial planes and accessible fields; the triangular conventional cutting point is indicated for firm, fibrous tissues, while the taper point is reserved for delicate, well-perfused tissues (vessels, parenchyma) and the trocar point for intermediate tissues.
In the Cahnos catalogue you will find the PDO/PDS family in other gauges, needle sizes and presentations: AM418GS6020 and AM418GS6040 (standard quality, straight GS60 needle, 2/0 and 4/0), the Prime line AMP418GS6020 / AMP418GS6030 / AMP418GS6040 (same configuration with superior quality), as well as ½ circle needles with taper point and trocar point, double needle and loop format, always in a box of 12 units. As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference and batch for traceability in the operating theatre. Store in a cool, dry place, below 30 °C and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews