We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone (PDO) Suture Prime · Needle 3/8 Circle Cylindrical Body Tapercut Trocar Point 13 mm (DRT13) · USP 6/0 (Metric 0.7) · Violet · 70 cm · Box of 12 units · Ref. P418DRT1360

Original price was: 74,08 €.Current price is: 62,60 €.

Absorbable monofilament polydioxanone (PDO) suture from the Prime range, mounted on an atraumatic needle of ⅜ circle, cylindrical body and Tapercut trocar point of 13 mm (DRT13). USP gauge 6/0 (metric 0.7) with violet thread of 70 cm, highly visible on the surgical field. Predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 and 45% at 8: prolonged support for slow-healing tissues. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Presentation in a box of 12 units · Factory reference P418DRT1360 (SKU AMP418DRT1360).

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418DRT1360

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO) suture from the Prime range is the reference choice when tissue needs prolonged support during healing with fully predictable absorption. This presentation combines a 70 cm violet thread in USP 6/0 gauge with a ⅜ circle needle, cylindrical body and 13 mm trocar point (Tapercut) (DRT13), a geometry designed to penetrate medium and firm consistency tissues with great precision and minimal trauma.

Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality consistency with CE marking and gauges conforming to USP/European Pharmacopoeia. Price per box of 12 units.

2. Technical explanation of the material and procedure

Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics, completing between 180 and 210 days. As a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilament threads. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.

The DRT13 needle combines a cylindrical non-cutting body with a sharpened trocar point (Tapercut): it penetrates intermediate and firm consistency tissues with lower penetration force, separating fibres without a cutting effect on adjacent tissue. Its ⅜ circle arc (approx. 135°) is especially valued in reduced surgical fields and precision techniques. The high-visibility violet colour improves thread contrast on the surgical field. It is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics

Property Specification
Reference / SKU P418DRT1360 (factory reference) / AMP418DRT1360 (SKU Cahnos)
Brand / quality Prime range
Material Polydioxanone (PDO), synthetic absorbable monofilament polymer
Thread structure Monofilament (non-braided)
Gauge / size USP 6/0 (metric 0.7) · conforming to USP / European Pharmacopoeia
Approximate diameter 0.070 – 0.099 mm (USP/EP standard)
Thread length 70 cm (1 thread per unit)
Thread colour High-visibility violet
Needle shape 3/8 circle (approx. 135°)
Needle body Cylindrical
Needle tip Trocar (Tapercut)
Needle size DRT13 – 13 mm (Prime)
Swaged 1 needle per suture
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (EO) — sterile, single-use, non-resterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units (individual pouches)

3.2. Tensile strength retention profile

Time after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis, skin and structures subjected to sustained tension.

3.3. Size equivalence

USP size Metric size Approximate diameter
6/0 (this product) 0.7 (EP) 0.070 – 0.099 mm (USP/EP)

4. Equivalences and Cross-References

Polydioxanone monofilament is the material basis of the market reference lines for long-term absorbable sutures (PDS-type family). The code AMP418DRT1360 is the distribution SKU of Cahnos for this article; the manufacturer’s official construction for this same suture (Prime range, DRT13 needle 13 mm, USP 6/0, violet, 70 cm, box of 12 units) is P418DRT1360.

Regarding the verified configuration of this data sheet (⅜ circle needle, cylindrical body and 13 mm Tapercut trocar point, USP 6/0 gauge, 70 cm violet thread), no reference from another manufacturer matching field by field (material, gauge, ⅜ curvature, trocar point family, 13 mm size, 70 cm length and colour) has been found in public sources, so it is not possible to declare an exact verified reference equivalence with third parties. References from another commercial house must not be treated as 1:1 interchangeable without validation by the technical department.

As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size, as well as the attachment. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

There is no equivalence table validated by the manufacturer for this specific configuration; consult the technical department of Cahnos before using in a tender.

5. Selection tips and variants of interest

USP 6/0 gauge (metric 0.7) is one of the most requested in ophthalmic surgery, microsurgery and approximation of delicate low-tension tissues, where it combines a very fine diameter with excellent initial tensile strength and minimal tissue footprint. The ⅜ circle needle with 13 mm trocar point (Tapercut) (DRT13 Prime) is the recommended choice for medium-consistency tissues and reduced-access fields; for soft and friable tissues, the conical point profile (Taperpoint) may be considered and, for firmer tissues, longer needles.

Variants of interest in the catalogue: AMP418DRT1350 (same DRT13 needle, USP 5/0 gauge), AMP418DR1360 (same fineness with 13 mm Taperpoint conical point), AMP418DR1360-2 (double 13 mm conical needle, 6/0 gauge, for continuous suturing). For shorter absorption profiles with the same needle and gauge, see the PGA range (AMP118DRT1360) and polyglactin 910 (P1L18DRT1360).

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO), synthetic absorbable monofilament polymer

Suture type

Synthetic absorbable monofilament (long-term)

Product line

Prime range

USP size

6/0 (metric 0.7)

Thread diameter

0.070 – 0.099 mm (USP/EP standard)

Thread colour

High-visibility violet

Needle shape

3/8 circle (approx. 135°)

Needle body

Cylindrical

Needle size

DRT13 – 13 mm (Prime)

Swaged

1 needle per suture

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

10 boxes

Regulatory standard

USP / European Pharmacopoeia (EP)

Manufacturer reference

P418DRT1360

Medida de aguja

DRT 13

Usp

6/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

3/8 circle

Calidad sutura

Prime

Estructura hilo

Braided multifilament

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone (PDO) Suture Prime · Needle 3/8 Circle Cylindrical Body Tapercut Trocar Point 13 mm (DRT13) · USP 6/0 (Metric 0.7) · Violet · 70 cm · Box of 12 units · Ref. P418DRT1360”

Your email address will not be published. Required fields are marked *