Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture Ref. AM418HR1330 is the long-lasting synthetic absorbable solution your operating theatre needs when tissue requires prolonged tensile support and fully predictable absorption. Made from poly(p-dioxanone) polymer, it offers excellent initial tensile strength, smooth passage through tissue and great knot security.
This presentation incorporates an atraumatic half-circle needle with cylindrical body and 13 mm Taperpoint conical point (HR13), USP 3/0 gauge (metric 2), 70 cm violet fluted thread, in a professional box of 12 units, designed for stock management in operating theatres, hospitals and purchasing centres, with special B2B terms for volume buyers.
2. Technical explanation of the material and procedure
Polydioxanone (PDO) is a synthetic absorbable polymer presented in a monofilament structure: a single smooth strand with no bacterial anchorage zones, very low memory, excellent handling and smooth glide through tissue. As it has no wicking effect or capillarity, it reduces bacterial adherence compared with multifilaments and minimises the inflammatory response, making it the reference configuration when prolonged support is required in tissues under sustained tension.
Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with complete absorption between 180 and 210 days. The half-circle needle with cylindrical body and conical point (Taperpoint geometry) of 13 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and well-perfused tissues (vessels, parenchyma, friable tissues), with controlled passage and minimal injury along the penetration path, making it ideal for paediatric cardiovascular surgery and ophthalmology. The fluted violet colour ensures optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AM418HR1330
| Parameter | Specification |
| Reference (SKU) | AM418HR1330 |
| Factory reference | 418HR1330 |
| Quality / range | Standard quality |
| Suture type | Synthetic absorbable monofilament |
| Composition | Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone) |
| Thread structure | Grooved monofilament |
| USP / metric gauge | 3/0 (metric 2) |
| Thread diameter | 0.20 – 0.249 mm (USP/EP standard) |
| Thread colour | Violet (high visibility) |
| Thread length | 70 cm |
| Needle shape | ½ circle (half circumference) |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint, atraumatic |
| Needle size | HR13 – 13 mm |
| Absorption mechanism | Hydrolysis |
| Total absorption | 180 – 210 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 units |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 4 weeks | 60 – 70 % of the initial tensile strength |
| 8 weeks | 45 % of the initial tensile strength |
| Total absorption | 180 – 210 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Monofilament polydioxanone is the most well-established long-acting absorbable raw material in surgical practice (classic ‘PDS-type’ family), with hydrolysis absorption of 180–210 days and tensile strength retention of 75/60–70/45% at 2/4/8 weeks. For the USP 3/0 configuration + 13 mm conical HR13 needle + 70 cm thread, commercial references from the PDS II line have been checked against primary sources (GUDID database and official Ethicon data sheet) that match some of the required comparison fields (material, gauge, attachment, curvature, point and needle size), but none fully meets all of them and, therefore, they cannot be considered 1:1 interchangeable with this technical data sheet:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | PDS II – polydioxanone monofilament, violet | Z149H (verified in GUDID, DI 10705031060289, and official Ethicon EPC data sheet): 6/0, RB-2/RB-2 taper point needle, half-circle 13 mm, 75 cm, 36 units | Comparable by category (not interchangeable 1:1) | They match on PDO polymer, half-circle curvature, conical point and needle size (13 mm); they differ in gauge (6/0 vs 3/0), attachment (double RB-2 needle vs single needle), thread length (75 cm vs 70 cm) and presentation (36 units vs 12 units). |
| Ethicon (Johnson & Johnson MedTech) | PDS II – polydioxanone monofilament, violet (RB-1 taper point needle 17 mm) | Z305H (verified in official Ethicon EPC data sheet and authorised distributors): 3/0, RB-1 taper point needle, half-circle 17 mm, 36 units | Comparable by category (not interchangeable 1:1) | They match on polymer, USP 3/0 gauge, curvature, conical point and colour; they differ in needle size (17 mm vs 13 mm, out of tolerance) and presentation (36 units vs 12 units). |
| Ethicon (Johnson & Johnson MedTech) | PDS II – polydioxanone monofilament, violet (SH taper point needle 26 mm) | Z316H (cited in Ethicon catalogue as 3/0, 70 cm, violet, SH 26 mm needle ½ circle conical point) | Comparable by category (not interchangeable 1:1) | They match on polymer, USP 3/0 gauge, thread length (70 cm), curvature and conical point; they differ in needle size (26 mm vs 13 mm, out of tolerance) and presentation. |
There is no equivalence table validated by the manufacturer that officially cross-references this item (USP 3/0 + 13 mm HR 13 needle + 70 cm thread) with the exact coding of other commercial brands; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: the line PDS II and PDS Plus from Ethicon (the latter with triclosan antibacterial coating, only where its use is approved), the line MonoPlus from B. Braun (violet polydioxanone monofilament), the line Surgicryl Monofilament from SMI and the line DemeDIOX from DemeTECH. All must be checked in their technical data sheet or official IFU (USP gauge, thread length, colour, curvature, body, point and needle size). The brands cited belong to their respective manufacturers and are mentioned only for comparative reference.
5. Selection tips and variants of interest
USP 3/0 gauge (metric 2) combines excellent initial tensile strength with a fine-to-medium diameter, indicated for approximating tissues under moderate tension (skin, subcutaneous tissue, mucosa, fascia, muscle) and ligation of medium-to-fine vessels, where reliable support is required during the first weeks of healing. The half-circle needle with 13 mm Taperpoint conical point is the most atraumatic option for soft and friable tissues and for reduced-radius access; if a greater penetration arc is required, 17 or 26 mm needles from the same PDO family may be considered.
Variants from the same Cahnos catalogue (same PDO/PDS family, HR 13 mm needle, 70 cm violet thread): AMP418HR1330, same USP 3/0 configuration in Prime quality for higher performance requirements; AM418HR1310 (USP 0), AM418HR1320 (USP 2/0), AM418HR1340 (USP 4/0) and AM418HR1350 (USP 5/0), for lower or higher gauge profiles depending on the tissue; AM418HR1730, same family with 17 mm HR17 needle; and AM418HRT2630, trocar point (Tapercut) HRT26 version for tougher tissues. Medium-absorption alternatives (PGA or polyglactin 910) with the same needle and gauge are also available.
All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalents from other commercial brands, contact our technical-commercial team.





Reviews
There are no reviews yet.