Description
1. Commercial Introduction
The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime range by Cahnos is the reference choice for hospitals, private clinics, ophthalmologists and purchasing groups looking for a long-lasting absorbable synthetic thread with a very competitive price-quality ratio. Its ½ circle needle with triangular body and reverse cutting point of 40 mm (HS 40) and its 90 cm violet fluted monofilament thread ensure firm, controlled penetration in dense tissues, optimal visibility in the surgical field and predictable behaviour with every stitch.
Manufactured under strict quality standards, it combines minimal tissue reaction with excellent tensile strength and secure knot tying, ensuring consistent clinical results. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes to guarantee continuous supply for your centre.
2. Technical Explanation
Polydioxanone is an absorbable synthetic polymer (poly(p-dioxanone)) that degrades by hydrolysis, i.e. through contact with organic fluids, with minimal inflammatory response. Its monofilament structure facilitates the passage of the thread through tissue with less friction and eliminates interstitial spaces, reducing the risk of bacterial colonisation compared to braided threads.
This presentation combines that structure with a ½ circle needle with triangular body and reverse cutting point (inverted triangular, ‘reverse cutting’) of 40 mm, designed to penetrate firm, dense tissues —aponeurosis, fascia, sclera— with controlled trauma and without tearing. The prolonged absorption profile (180-210 days) makes it ideal for tissues that take more than six weeks to regain their strength, with wound support maintained during healing. Product sterile by ethylene oxide, single-use and not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference AMP413HS4010
| Characteristic | Specification |
|---|---|
| Reference (SKU) | P413HS4010 (SKU AMP413HS4010) |
| Range / Quality | Prime (superior quality) |
| Material | Polydioxanone (PDO/PDS), synthetic monofilament |
| Thread structure | Grooved monofilament |
| Gauge | USP 0 (metric 3.5) |
| Colour | Fluted violet |
| Needle shape | ½ circle |
| Needle body | Triangular |
| Tip type | Triangular with reverse cutting (reverse cutting) |
| Needle size | HS 40 mm |
| Thread length | 90 cm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 180-210 days |
| Sterilisation | Ethylene oxide (single-use) |
| Tissue reaction | Minimal |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
Complete absorption by hydrolysis between 180 and 210 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues, ophthalmology and fascia closure.
4. Equivalences and Cross-References
Polydioxanone monofilament is a family of long-lasting absorbable sutures that is clinically comparable to the main lines on the international market. Below are listed the references verified against the catalogue or sources from the authorised distributor of the cited manufacturer:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS Plus (polydioxanone with triclosan) — ½ circle reverse cutting triangular point needle 40 mm, violet, 90 cm | PDP9324H | Comparable by category (not interchangeable 1:1) | Same material (PDO), same needle geometry (reverse cutting 40 mm) and same thread length (90 cm); differs in gauge (USP 1 vs USP 0) and incorporates antimicrobial triclosan coating. Verify gauge before substituting. |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone) — CP needle ½ circle reverse cutting triangular point 40 mm, violet | Z195T | Comparable by category (not interchangeable 1:1) | Same family (PDO) and same reverse cutting needle of 40 mm; differ in thread length (70 cm vs 90 cm) and gauge, which must be verified in the official source of each batch (cited as size 2 or 2/0 depending on distributor). |
There is no equivalence table validated by the manufacturer for cross-brand comparison in the exact configuration of HS 40 mm triangular needle with 90 cm thread in USP 0 gauge; consult the technical department before use in tenders. For any formal substitution, the material, gauge (USP 0), needle size and geometry (½ circle, triangular body and point, radius 40 mm), thread length (90 cm), colour and regulatory classification of each reference must be verified one by one, as small variations prevent a 1:1 equivalence. Within the same clinical category, the MonoPlus polydioxanone monofilament line from B. Braun is comparable at category level, not interchangeable 1:1.
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, fascia closure, abdominal wall and soft tissue approximation with moderate tension. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing; if an even more atraumatic entry into soft tissue is preferred, consider the conical point variants of the same gauge.
Within the PDO family from Cahnos, the following variants of interest are available:
- AM413HS4010: PDO normal quality USP 0, HS 40 mm triangular needle, violet, 90 cm (direct equivalent in specifications).
- AM413HR4001 / AM413HR4002: PDO USP 1 / USP 2, ½ circle conical HR 40 mm needle, violet, 90 cm (larger gauge for more tension).
- AM415HRT40L10: PDO USP 0, ½ circle Tapercut trocar point HRT 40 mm needle, violet, 150 cm with loop (ideal for continuous suturing and reduced fields).
- AMP415HR40L10: PDO Prime USP 0, conical HR 40 mm needle, violet, 150 cm with loop (Prime range for laparoscopy).
As a sterile single-use product, always check the integrity of the packaging before each procedure and comply with the traceability required by the centre. For special B2B conditions and volume orders, contact our technical-commercial team.