Description
1. Commercial Introduction
The 15 x 15 cm gauze swab with radiological contrast thread (X-ray) is an essential consumable in wound dressing services, surgical block and hospitalisation units. It is a globular dressing made of 100% hydrophilic cotton, with outstanding absorption capacity and a feature that makes it especially valuable in surgery: it incorporates a radiopaque thread that allows its location by X-rays if it were retained in a cavity, contributing to patient safety and systematic material counting.
Presented in a box of 100 units, this reference offers a very competitive price-quality ratio for continuous consumption, with the guarantee of a professional-use product ready to be integrated into the usual wound care and operating theatre protocols of your centre.
2. Technical Explanation
Gauze swabs are globular dressings: flat dressings that, through a shaping process, adopt an almost spherical or globular shape. They are classified according to the gauze fabric from which they are made and are manufactured with straight gauze of 100% hydrophilic cotton, with or without radiological contrast thread.
This 15 x 15 cm gauze swab incorporates a radiopaque thread (X-ray), an essential safety element in surgical environments: being visible on the radiographic image, it allows rapid confirmation that no material has been left inside the patient at the close of the procedure. Its globular shape and high wiping capacity make it suitable for wound cleaning, absorption of bleeding and fluids, application of antiseptics, and packing or temporary filling of cavities during the surgical procedure.
They are surgical dressings that can be supplied in sterile presentation. According to the technical data sheet of the family (refs. 51101–51105), they may contain latex if they incorporate an internal toroidal fastening; check the labelling of the received batch when the protocol requires latex-free material.
3. Technical Specifications
The reference specifications of the gauze swab and its commercial presentation are set out below:
| Characteristic | Detail |
|---|---|
| Reference (SKU) | 51102 |
| Product type | Gauze swab (globular dressing) with radiological contrast thread |
| Material | Straight gauze made of 100% hydrophilic cotton |
| Measurements | 15 x 15 cm |
| Radiological contrast | Yes, RX thread detectable on radiographic image |
| Shaping | Flat dressing formed into a globular shape |
| Sterility | Available in sterile presentation (surgical dressing) |
| Latex | May contain latex if it has an internal toroidal fastening (check labelling) |
| Reference standards | UNE-EN 14079 / DIN EN 14079 (absorbent cotton gauze) |
| Presentation | Box of 100 units |
| Scope of use | Wound dressings, wound cleaning, fluid control and operating theatre material |
The range of gauze swabs with X-ray in the catalogue is completed in the following formats, from smallest to largest surface area:
| Reference | Measurements | Presentation |
|---|---|---|
| 51101 | 10 x 10 cm | Box of 100 units |
| 51102 | 15 x 15 cm | Box of 100 units |
| 51103 | 20 x 20 cm | Box of 100 units |
| 51104 | 25 x 25 cm | Box of 100 units |
| 51105 | 33 x 33 cm | Box of 100 units |
4. Equivalences and Cross-References
Gauze swabs with X-ray detectable thread are a standardised product category in the European hospital market, usually manufactured in accordance with the functional requirements of standard DIN EN 14079 / UNE-EN 14079 for absorbent cotton gauze with contrast thread. References from other manufacturers verified against the official catalogue are listed below, which correspond to this same category:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Lohmann & Rauscher | Gazin – gauze swab with RX detectable thread, 20 threads | 15184 | Comparable by category (not interchangeable 1:1) | Non-sterile gauze swab, plum size, 20 threads, with silicone safety ring and RX detectable thread, in accordance with DIN EN 14079; the size is defined by size designation and not in cm, sterilizable before use and packed in film bag (official L&R catalogue / authorised distributor). |
| Lohmann & Rauscher | Gazin – gauze swab with RX detectable thread, 20 threads | 15185 | Comparable by category (not interchangeable 1:1) | Non-sterile gauze swab, egg size, 20 threads, with silicone safety ring and RX detectable thread, in accordance with DIN EN 14079; non-matching presentation (non-sterile, film bag, 500 units). |
| Lohmann & Rauscher | Gazin – gauze swab with RX detectable thread, 20 threads | 15223 | Comparable by category (not interchangeable 1:1) | Non-sterile gauze swab, fist size, 20 threads, RX detectable thread, in accordance with DIN EN 14079; non-matching presentation (non-sterile, film bag, 250 units). |
Other companies such as Texpol (Spain) market absorbent hydrophilic gauze swabs 100% cotton with or without RX thread, sterile or non-sterile, with a retaining ring and absence of loose threads, in accordance with UNE EN 14079; the numerical codes of the RX swabs in equivalent size (T/1, 15 x 15 cm) could not be verified in a public primary source, so they are not included in the table. There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
5. Selection tips and variants of interest
Select the 15 x 15 cm gauze swab when you need an intermediate format with high manoeuvrability: wound dressings for small or medium-sized wounds, surgical cleaning of reduced fields, application of antiseptics and bleeding control in minor surgery procedures or in paediatrics. For larger surfaces, consider references 51103 (20 x 20 cm), 51104 (25 x 25 cm) or 51105 (33 x 33 cm); if the procedure requires a minimal field, reference 51101 (10 x 10 cm) is the most compact option in the range. All formats share the same composition of hydrophilic cotton and the same radiopaque thread.
Always check the condition of the packaging and, in sterile presentations, the expiry date and the integrity of the seal before use. In procedures with a risk of retention, perform the swab count at the start and at the end of the procedure and confirm the removal with radiographic control if the protocol requires it. For applications where a flat material without globular conformation is required, consult the rest of the gauze range in the catalogue (gauze sachets of 17 threads, ref. 32704 in 25 x 25 cm with RX; or sterile gauze sachets 20 x 40 cm RX, ref. 32424). For institutional orders, tenders or operating theatre supplies, our technical-commercial department will advise you on special conditions and homologation equivalences.