Description
1. Transparent and effective protection for superficial wounds
The transparent adhesive dressing Suprasorb F from Lohmann & Rauscher (L&R), in 10 x 12 cm format (reference 20462) and supplied in a box of 10 units, is the usual choice of hospitals, clinics, care homes and nursing services for the wound care of superficial non-infected wounds with light exudate: blisters, chafing, abrasions and wounds in the epithelialisation phase.
Its transparency allows the wound to be monitored without having to remove the dressing, and its self-adhesive structure adapts elastically to body contours, relieving pressure and pain immediately and speeding up recovery by preventing further friction. It is the ideal choice for protecting fragile skin, securing lines and moist wound healing.
2. Technical Explanation
Suprasorb F is a semipermeable film dressing consisting of a polyurethane film coated with a polyacrylate adhesive free from colophony, colophony derivatives and latex, which minimises the risk of sensitisation and makes it suitable for sensitive skin. It also incorporates a polyester support film coated on both sides with polyethylene and silicone-coated on one side, plus a silicone-coated protective paper.
The adhesive side is protected by two white silicone-coated papers overlapping in the centre: the central area does not adhere to the wound, so removal is painless and atraumatic. The dressing is breathable and permeable to moisture vapour (allowing excess moisture to evaporate while maintaining the moist environment necessary for healing) and impermeable to water, liquids and external microorganisms, protecting the new epithelial tissue. It is antistatic, easy to apply and remove, and is supplied sterile, sterilised by ethylene oxide, in individual packaging.
As a primary dressing it is suitable for superficial wounds with low exudate; as a secondary dressing it allows fixation of primary dressings and retention of cannulas, infusion catheters and drainage tubes.
3. Technical Specifications
| Parameter | Specification |
| Manufacturer | Lohmann & Rauscher (L&R) |
| Family | Suprasorb F – semipermeable film dressing |
| Official manufacturer reference | 20462 (this product, box of 10 units); 20463 (box of 50 units) |
| Measurements | 10 x 12 cm |
| Material | Polyurethane film/sheet with polyacrylate adhesive |
| Adhesive | Polyacrylate, free from colophony, colophony derivatives and latex |
| Breathability | Yes, permeable to moisture vapour (maintains the moist healing environment) |
| Waterproof rating | Impermeable to water, liquids and external microorganisms |
| Additional properties | Antistatic, elastic, adapts to body contours |
| Sterility | Sterile, sterilised by ethylene oxide, individual packaging |
| Indications | Superficial non-infected wounds with light exudate; protection of new epithelial tissue; secondary dressing; prevention (incl. pressure ulcers); retention of dressings, cannulas, catheters and tubes |
| Change interval | At the clinician’s discretion, maximum 5–7 days |
| Presentation | Box of 10 units in individual cellulose-polyethylene bag, with case and instructions for use |
| Use | Single-use |
Suprasorb F range according to the official L&R catalogue (verified references):
| Measurements | Reference | Units per box |
| 5 x 7 cm | 20460 / 20461 | 10 / 100 |
| 10 x 12 cm (this product) | 20462 / 20463 | 10 / 50 |
| 10 x 25 cm | 20464 | 10 |
| 15 x 20 cm | 20465 | 10 |
| 20 x 30 cm | 20466 | 10 |
| Roll 10 cm x 1 m / 10 cm x 10 m / 15 cm x 10 m | 20467 / 20468 / 20469 | Non-sterile, for prevention and fixation |
4. Equivalences and Cross-References
Exact reference equivalence (same manufacturer, same dimensions, same technology): reference 20463 – Suprasorb F 10 x 12 cm, box of 50 units, sterile – is the same L&R dressing as the present one (ref. 20462) in a larger volume presentation.
Comparable at category level (not 1:1 interchangeable): transparent polyurethane film dressings from other manufacturers, with which it shares clinical indication and technology (sterile semipermeable adhesive film), but from which it differs in adhesive, application system, dimension or presentation:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Lohmann & Rauscher | Suprasorb F 10 x 12 cm (50 units) | 20463 | Exact reference equivalence | Same dressing as ref. 20462 in 50-unit presentation; polyurethane film, polyacrylate adhesive without latex or colophony, sterile by ethylene oxide |
| Solventum (3M) | Tegaderm Transparent Film, Frame Style | 1626W | Comparable by category | 10 x 12 cm (box of 50); polyurethane film with application frame; hypoallergenic acrylic adhesive without latex; bacterial and viral barrier (confirmed in the manufacturer’s official catalogue) |
| Smith+Nephew | Opsite Flexigrid | 4629 | Comparable by category | 10 x 12 cm (box of 10); polyurethane film with wound measurement grid; acrylic adhesive (confirmed with authorised distributors) |
| Mölnlycke | Mepore Film | 271500 | Comparable by category | 10 x 12.5 cm; transparent polyurethane film with polyacrylate adhesive; the 12.5 cm dimension does not match the 12 cm; confirm reference and European presentation with the manufacturer before use |
Important: L&R does not publish an official cross-reference table with other brands. Equivalences between manufacturers must always be validated against the technical data sheet and IFU of each product; consult our technical department before use in tenders or catalogue substitution.
5. Selection tips and variants of interest
Format 10 x 12 cm (ref. 20462 box of 10 units / ref. 20463 box of 50 units): ideal for larger superficial wounds, minor post-operative wounds, protection of at-risk skin and as a secondary dressing over primary dressings. The box of 10 units is suitable for occasional use; the 50-unit box is the economical format recommended for centres, nursing services and volume purchases.
Format 5 x 7 cm (refs. 20460/20461): for small wounds, blisters, chafing, puncture sites and peripheral lines.
Format 10 x 25 cm (ref. 20464): indicated for retention of catheters, cannulas and drainage tubes, as well as for covering elongated primary dressings.
Larger formats (15 x 20 cm, ref. 20465; 20 x 30 cm, ref. 20466): for extensive wounds, protection of skin at risk and secondary dressing for large surfaces.
Non-sterile roll (refs. 20467–20469): for prevention of pressure ulcers and securing dressings, when sterility is not required.
Clinical criterion: the change interval is determined by the clinician according to the wound condition, the exudate level and the primary dressing used, without exceeding 5–7 days. In the event of abundant secretion or signs of infection, select a dressing with absorption capacity.






Reviews