Description
1. Transparent and effective protection for superficial wounds
The transparent adhesive dressing Suprasorb F from Lohmann & Rauscher (L&R), in 5 x 7 cm format (reference 20460) and presented in a box of 10 units, is the usual choice of hospitals, clinics, care homes and nursing services for the wound care of superficial non-infected wounds with light exudate: blisters, chafing, abrasions and wounds in the epithelialisation phase.
Its transparency allows the wound’s progress to be monitored without having to remove the dressing, and its self-adhesive structure adapts elastically to body contours, immediately relieving pressure and pain and speeding up recovery by preventing further friction. It is the ideal choice for protecting fragile skin, securing lines and moist wound healing.
2. Technical Explanation
Suprasorb F is a semipermeable film dressing made of a polyurethane sheet coated with a polyacrylate adhesive free from colophony, colophony derivatives and latex, which minimises the risk of sensitisation and makes it suitable for sensitive skin. It also incorporates a polyester support sheet coated on both sides with polyethylene and silicone-coated on one side, plus a silicone-coated protective paper.
The adhesive side is protected by two overlapping white silicone-coated papers in the centre: the central area does not adhere to the wound, so removal is painless and atraumatic. The dressing is breathable and permeable to moisture vapour (allowing excess moisture to evaporate while maintaining the moist environment needed for healing) and impermeable to water, liquids and external microorganisms, protecting the new epithelial tissue. It is antistatic, easy to apply and remove, and is supplied sterile, sterilised by ethylene oxide, in individual packaging.
As a primary dressing it is suitable for superficial wounds with low exudate; as a secondary dressing it allows fixation of primary dressings and retention of cannulas, infusion catheters and drainage tubes.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Lohmann & Rauscher (L&R) |
| Family | Suprasorb F – film dressing (film wound dressing) |
| Official manufacturer reference | 20460 (this product, box of 10 units); 20461 (box of 100 units) |
| Measurements | 5 x 7 cm |
| Material | Polyurethane film/sheet with polyacrylate adhesive |
| Adhesive | Polyacrylate, colophony-free, free of colophony derivatives and latex-free |
| Breathability | Yes, permeable to moisture vapour (maintains moist healing environment) |
| Waterproof rating | Impermeable to water, liquids and external microorganisms |
| Additional properties | Antistatic, elastic, adapts to body contours |
| Sterility | Sterile, sterilised by ethylene oxide, individual packaging |
| Indications | Superficial non-infected wounds with light exudate; protection of new epithelial tissue; secondary dressing; prevention (incl. pressure ulcers); retention of dressings, cannulas, catheters and tubes |
| Change interval | At the clinician’s discretion, maximum 5–7 days |
| Presentation | Box of 10 units in individual cellulose-polyethylene bag, with case and instructions for use |
| Use | Single-use |
Suprasorb F range according to L&R official catalogue (verified references)
| Measurements | Reference | Units per box |
|---|---|---|
| 5 x 7 cm (this product) | 20460 / 20461 | 10 / 100 |
| 10 x 12 cm | 20462 / 20463 | 10 / 50 |
| 10 x 25 cm | 20464 | 10 |
| 15 x 20 cm | 20465 | 10 |
| 20 x 30 cm | 20466 | 10 |
| Roll 10 cm x 1 m / 10 cm x 10 m / 15 cm x 10 m | 20467 / 20468 / 20469 | Non-sterile, for prevention and fixation |
4. Equivalences and Cross-References
Exact reference equivalence (same manufacturer, same dimensions, same technology): reference 20461 – Suprasorb F 5 x 7 cm, box of 100 units, sterile – is the same L&R dressing in a larger-volume presentation; reference 20460 (this data sheet) is the box of 10 units.
Comparable at category level (not interchangeable 1:1): transparent polyurethane film dressings from other manufacturers, with which it shares clinical indication and technology (sterile semipermeable adhesive film), but from which it differs in size, adhesive or application system:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Lohmann & Rauscher | Suprasorb F 5 x 7 cm (100 units) | 20461 | Exact reference equivalence | Same dressing as ref. 20460 in 100-unit presentation; polyurethane film, polyacrylate adhesive without latex or colophony, sterile by ethylene oxide |
| 3M / Solventum | Tegaderm Film | 1624W | Comparable by category | Size 6 x 7 cm (box of 100); polyurethane film with application frame; the 5 cm dimension does not match |
| Mölnlycke | Mepore Film | Exact reference for 5 x 7 cm pending confirmation | Not verified | Transparent polyurethane film with polyacrylate adhesive; confirm reference and presentation with the manufacturer before use |
Important: L&R does not publish an official cross-reference table with other brands. Equivalences between manufacturers must always be validated against the technical data sheet and IFU of each product; consult our technical department before using it in tenders or catalogue substitutions.
5. Selection tips and variants of interest
- Format 5 x 7 cm (ref. 20460 box of 10 units / ref. 20461 box of 100 units): ideal for small, superficial wounds, blisters, chafing, puncture sites, peripheral lines and delicate skin areas. The box of 10 units is the suitable format for occasional use; the box of 100 units is the economical option for centres, nursing services and volume purchases.
- Format 10 x 12 cm (ref. 20462/20463): for larger superficial wounds, post-operative wounds and as a secondary dressing over primary dressings.
- Format 10 x 25 cm (ref. 20464): indicated for securing catheters, cannulas and drainage tubes, as well as for covering elongated primary dressings.
- Larger formats (15 x 20 cm, ref. 20465; 20 x 30 cm, ref. 20466): for extensive wounds, protection of at-risk skin and as a secondary dressing for large areas.
- Non-sterile roll (refs. 20467–20469): for pressure ulcer prevention and dressing fixation, when sterility is not required.
Clinical criteria: the change interval is determined by the clinician according to the wound condition, the level of exudate and the primary dressing used, without exceeding 5–7 days. In the presence of heavy exudate or signs of infection, select a dressing with absorbent capacity.