Description
1. Transparent and effective protection for superficial wounds
The transparent adhesive dressing Suprasorb F from Lohmann & Rauscher (L&R), in its 5 x 7 cm format (reference 20461), is a semipermeable polyurethane film dressing designed for the wound care of superficial non-infected wounds with light secretion, such as blisters, abrasions, chafing and wounds in the epithelialisation phase. Its transparency allows the wound to be monitored without removing the dressing, and its self-adhesive structure adapts elastically to the most difficult body contours, offering a high level of wearing comfort. It is the usual choice of hospitals, clinics, care homes and nursing services for the protection of fragile skin, the fixation of lines and moist wound care.
2. Technical Explanation
Suprasorb F consists of a polyurethane film coated with a polyacrylate adhesive free from colophony, colophony derivatives and latex, which minimises the risk of sensitisation and makes it suitable for sensitive skin. It also has a polyester support film coated with polyethylene on both sides and silicone-coated on one side, plus a silicone-coated protective paper. The adhesive side is protected by two white silicone-coated papers overlapping in the centre: the central area does not adhere to the wound, so removal is painless and atraumatic.
The dressing is breathable and permeable to moisture vapour (allowing excess moisture to evaporate while maintaining the moist environment necessary for healing) and impermeable to water and external microorganisms, protecting the new epithelial tissue against bacteria and liquids. It is antistatic, easy to apply and remove, and is supplied sterile (sterilised by ethylene oxide) in individual packaging. Its use as a primary dressing is suitable for superficial wounds with low exudate; as a secondary dressing it allows the fixation of primary dressings, as well as the retention of cannulas, infusion catheters and drainage tubes.
3. Technical Specifications
| Parameter | Specification |
| Manufacturer | Lohmann & Rauscher (L&R) |
| Family | Suprasorb F – film dressing (film wound dressing) |
| Official manufacturer reference | 20461 |
| Measurements | 5 x 7 cm |
| Material | Polyurethane film/sheet with polyacrylate adhesive |
| Adhesive | Polyacrylate, colophony-free, free of colophony derivatives and latex-free |
| Breathability | Yes, permeable to moisture vapour (maintains moist healing environment) |
| Waterproof rating | Impermeable to water, liquids and external microorganisms |
| Additional properties | Antistatic, elastic, adapts to body contours |
| Sterility | Sterile, sterilised by ethylene oxide, individual packaging |
| Indications | Superficial non-infected wounds with light secretion; protection of new epithelial tissue; secondary dressing; prevention (incl. pressure ulcers); retention of dressings, cannulas, catheters and tubes |
| Change interval | At the clinician’s discretion, maximum 5–7 days |
| Presentation | Box of 100 units in individual cellulose-polyethylene bag, with case and instructions for use |
| Use | Single-use |
Suprasorb F range according to L&R official catalogue (verified references)
| Measurements | Reference | Units per box |
| 5 x 7 cm (this product) | 20461 | 100 (also available ref. 20460 in box of 10) |
| 10 x 12 cm | 20462 / 20463 | 10 / 50 |
| 10 x 25 cm | 20464 | 10 |
| 15 x 20 cm | 20465 | 10 |
| 20 x 30 cm | 20466 | 10 |
| Roll 10 cm x 1 m / 10 cm x 10 m / 15 cm x 10 m | 20467 / 20468 / 20469 | Non-sterile, for prevention and fixation |
Coding note: the internal warehouse code «35.78» does not correspond to the manufacturer’s official nomenclature; the official L&R reference for this product is 20461.
4. Equivalences and Cross-References
Exact reference (same manufacturer, same measurements, same presentation): 20461 – Suprasorb F 5 x 7 cm, box of 100 units, sterile. Reference 20460 is the same dressing in a box of 10 units.
Comparable at category level (not interchangeable 1:1): transparent polyurethane film dressings from other manufacturers, with which it shares clinical indication and technology (sterile semipermeable adhesive film), but from which it differs in size, adhesive or application system:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Lohmann & Rauscher | Suprasorb F 5 x 7 cm (100 units) | 20461 | Exact reference equivalence | Product analysed; polyurethane film, polyacrylate adhesive without latex or colophony, sterile |
| 3M / Solventum | Tegaderm Film | 1624W | Comparable by category | Size 6 x 7 cm (box of 100); polyurethane film with application frame; the 5 cm dimension does not match |
| Smith+Nephew | Opsite Flexigrid | 4628 | Comparable by category | Size 6 x 7 cm (box of 100); incorporates wound measurement grid; polyurethane adhesive film |
| Mölnlycke | Mepore Film | Exact reference for 5 x 7 cm pending confirmation | Not verified | Transparent polyurethane film with polyacrylate adhesive; confirm reference and presentation with the manufacturer before use |
Important: L&R does not publish an official cross-reference table with other brands. Equivalences between manufacturers must always be validated against the technical data sheet and IFU of each product; consult our technical department before use in tenders or catalogue substitution.
5. Selection tips and variants of interest
- Format 5 x 7 cm (ref. 20461): ideal for small and superficial wounds, blisters, chafing, puncture sites, peripheral lines and delicate skin areas. The box of 100 units is the economical format recommended for centres, nursing services and volume purchases. If consumption is occasional, there is a box of 10 units (ref. 20460).
- Format 10 x 12 cm (ref. 20462/20463): for superficial wounds of larger surface area, post-operative wounds and secondary dressing over primary dressings.
- Format 10 x 25 cm (ref. 20464): indicated for the retention of catheters, cannulas and drainage tubes, as well as for covering elongated primary dressings.
- Larger formats (15 x 20 cm, ref. 20465; 20 x 30 cm, ref. 20466): for extensive wounds, protection of skin at risk and secondary dressing for large surfaces.
- Non-sterile roll (refs. 20467–20469): for prevention of pressure ulcers and fixation of dressings, when sterility is not required.
- Clinical criterion: the change interval is determined by the physician according to the state of the wound, the level of exudate and the primary dressing used, without exceeding 5–7 days. In the presence of abundant secretion or signs of infection, select a dressing with absorption capacity.







Reviews
There are no reviews yet.